envirovent Cyclone 7 Kitchen and Bathroom Extractor Fan Instruction Manual
- June 1, 2024
- envirovent
Table of Contents
- envirovent Cyclone 7 Kitchen and Bathroom Extractor Fan
- Safety
- Electrical Connection
- Diagrams
- Wiring Diagrams
- About the Product
- Cartridge Replacement
- Installation
- Performance Checklist
- ON-SITE INSTALLATION AFTER SALES SERVICE
- Cleaning
- Airflow Performance
- Optional Components
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
envirovent Cyclone 7 Kitchen and Bathroom Extractor Fan
Specifications:
- Model: CyClone 7
- Power Supply: 230V
- IP Rating: IPX4 SELV, IPX5
Safety
Before installation, ensure you read and understand the provided
instructions. The unit should be installed by a competent person.
Electrical Connection:
The unit must be able to be disconnected from the mains power after
installation. Incorporate a local isolator in the fixed wiring as per
regulations Connection to the fixed wiring should be outside the unit
following IET Wiring Regulations. Use the supplied flexible cable for the
power cable running into the cable gland.
If the mains cable is damaged, have it replaced by EnviroVent or an
authorized service agent to prevent hazards.
Do not tamper with the electronic circuit boards inside the unit. Ensure a
continuous electrical power supply without wiring through a light switch.
Wiring Regulations
All wiring must comply with Building Regulations and IET Wiring Regulations.
Have the final installation examined and tested by a qualified electrician.
If installing outside of the UK, consider changing the fuse in the pattress
box for SELV variants.
FAQ
Q: Can the CyClone 7 unit be mounted upside down?
A: No, mounting the unit upside down will void the warranty. It should be
installed according to the provided instructions.
Safety
- Read and understand these instructions before beginning installation. The unit should be installed by a competent person.
- Check there is space to fit the unit in your chosen location. As standard it can be installed using 100mm or 125mm inside diameter duct. With the optional adaptor, a 150mm duct can also be used.
- The unit can be wall mounted as standard, or ceiling, recess, inline and window mounted using optional kits (see page 15 for further information). The unit cannot be wall mounted upside down (with the electronic boards at the bottom) as this will void the warranty.
- Ensure the operation of the unit does not affect the operation of open-flue appliances. If you are unsure, please consult local regulations or a qualified gas engineer. Consider the external cowl location in relation to open flues from appliances e.g. boilers. You must
- ensure the cowl is positioned a minimum distance of 300mm away in all directions. Envirovent recommends at least 2m clearance.
- In kitchens, if the unit is fitted above a cooker, it must be installed a minimum distance of 1 metre above any hob, and not have a pullcord fitted.
- This unit is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision and usage instruction by a person responsible for their safety.
- Children should be supervised to ensure they do not play with the unit. Cleaning and user maintenance must not be performed by children.
Electrical Connection
- The unit must be able to be disconnected from the Mains supply after installation. When wiring the unit to the Mains power supply, a suitable local isolator must be incorporated in the fixed wiring in accordance with the IET Wiring Regulations.
- Connection to the fixed wiring must be made outside the unit in a suitable location, following IET Wiring Regulations.
- The power cable running into the cable gland must remain the supplied flexible cable (not a solid core lighting and mains cable). If any other type of cable is forced into the cable gland, the unit will be damaged, voiding the warranty.
- If the mains cable is damaged, it must be replaced by EnviroVent, an authorized service agent, or a similarly qualified person in order to avoid a hazard.
- Do not remove or tamper with the electronic circuit boards inside the product. The unit requires a continuous electrical power supply and should not be wired through a light switch.
Wiring Regulations
All wiring must comply with Building Regulations and the current IET Wiring
Regulations (BS7671 in the UK) or equivalent standards for other countries.
The final installation should be examined and tested by a qualified
electrician.
The fuse in the pattress box (SELV Variants) may need to be changed if the
product is installed outside of the UK.
This product is not suitable for use with a Type AC RCD
Diagrams
Wiring Diagrams
About the Product
Function
The EnviroVent Cyclone 7 has been developed to improve indoor air quality,
reduce humidity levels in kitchens and bathrooms and resolve condensation and
mould problems. It is designed to operate continuously for up to 7 years
without a major service.
Humidity Tracking
As standard, the unit is fitted with Intellitrac® Technology to sense the
relative humidity in the room. Once above the setpoint, the fan speed will
increase as humidity levels rise and decrease as humidity levels fall. This
intelligent function reduces energy costs, motor wear, and ensures a long life
for the product.
Pullcord
If your Cyclone 7 fan includes a pullcord, it can be used to engage the
maximum extraction rate for odour control. Pull down on the cord to increase
the unit to the maximum extraction rate. Pull down again to decrease the unit
back to the low extraction rate.
Cartridge Replacement
If necessary, the central cartridge can be exchanged for a replacement. The
removed cartridge can be returned to EnviroVent for recycling. This allows the
front cover, rear carcass and duct to remain intact throughout the life of the
property, eliminating the wasteful disposal of non-biodegradable material to
landfill sites.
Humidity Tracking
As standard, the unit is fitted with Intellitrac® Technology to sense the
relative humidity in the room. Once above the setpoint, the fan speed will
increase as humidity levels rise and decrease as humidity levels fall. This
intelligent function reduces energy costs, motor wear, and ensures a long life
for the product.
Pullcord
If your Cyclone 7 fan includes a pullcord, it can be used to engage the
maximum extraction rate for odour control. Pull down on the cord to increase
the unit to the maximum extraction rate. Pull down again to decrease the unit
back to the low extraction rate.
Cartridge Replacement
If necessary, the central cartridge can be exchanged for a replacement. The removed cartridge can be returned to EnviroVent for recycling. This allows the front cover, rear carcass and duct to remain intact throughout the life of the property, eliminating the wasteful disposal of non-biodegradable material to landfill sites.
Installation
ISOLATE THE MAINS SUPPLY BEFORE BEGINNING THE INSTALLATION
-
Loosen the two screws on the bottom of the unit, leave the screws in place and remove the front cover.
-
Pull the central cartridge out from inside the rear carcass.
-
Disconnect the green connector end of the power cable from the unit then set the central cartridge to one side.
-
Connect the power cable and local isolator to the Mains as in the wiring diagrams shown on page 5. Then tighten the cable gland on the rear carcass.
-
Insert the rear carcass into the wall duct.
-
Fix to the wall using four of the labelled fixing holes and the four screws and wall plugs provided.
-
If using a backdraught shutter, insert it fully. The disc must open towards the outside of the property.(D8
-
Insert provided caps into the fixing holes at the top of the rear carcass (1, 2, 3).
Not using these will void the IP rating and warranty.
Reconnect the green power connector to the unit. -
Insert the central cartridge into the rear carcass. Do not trap any of the cables. Fix in place using the four supplied screws.
-
To change unit settings, adjust switches 1 and 2 on the central cartridge.
- Default 230V duty is kitchen + Standard Trickle.
- Default SELV duty is bathroom + Standard Trickle.
-
Now apply the adhesive foam pad over the switches.
Not using this will void the warranty and IP rating. -
Ensure the impeller is fitted correctly, the two clips should both be engaged.
-
Replace the front cover ensuring the pullcord sits into the slot. Then tighten the two screws.
The unit will not operate without the front cover in place. -
The mains supply can now be reactivated.
Performance Checklist
- Is there power being supplied to the unit?
- Are all internal electrical connectors attached or have any been disconnected?
- Has the electronic circuit board been removed for any reason?
- Is the central cartridge correctly seated in the rear carcass with no stray wires obstructing it?
- Does the impeller spin freely? Ensure the two clips have been fully engaged.
- Is the front cover in place? The unit will not operate until the front cover is fitted.
- Does the pullcord activate? Ensure the pullcord is not trapped inside the unit.
ON-SITE INSTALLATION AFTER SALES SERVICE
Please ensure that you have read and understood the installation instructions. In the event of an on-site installation problem, or if you have any queries about the unit, just call us and ask to talk to a member of our technical team. In the majority of cases the issue can be resolved over the phone.
HOTLINE NUMBER: 01423 810 810
In cases where the problem cannot be resolved over the phone, contact your
wholesaler to agree a return.
On-site call outs are available, note that charges may apply.
Cleaning
ISOLATE THE UNIT FROM THE MAINS SUPPLY BEFORE CLEANING
- Remove the front cover.
- Push the impeller clips towards the centre, then pull the impeller out.
- Clean the front cover and impeller in warm soapy water and allow to dry. Use a damp cloth to clean any other parts of the unit. (Do not use solvents and do not clean any parts in a dishwasher appliance).
- Clip the impeller back into position, ensuring the clips are engaged. Replace the front cover and tighten both screws.
THE UNIT WILL NOT OPERATE UNTIL THE FRONT COVER IS FITTED
Airflow Performance
Setting | Power (W) | Duty (L/s) |
---|---|---|
Bathroom Trickle | 3 | 14 |
Bathroom Trickle+ | 4 | 21 |
Bathroom Boost | 14 | 41 |
Kitchen Trickle | 3 | 19 |
Kitchen Trickle+ | 4 | 22 |
Kitchen Boost | 30 | 55 |
Running costs
SELV variants run on bathroom duty only.
Product Variants
Wireless Remote Control
When the button on the remote control is pressed, the unit will extract at the
maximum extraction rate for up to 15 minutes then return to the low extraction
rate. The high extraction rate can be stopped early if required, by pressing
the button on the remote control within the 15 minutes. (Remote control units
do not include a pullcord).
Wired Remote Switch
On these units, a wired boost switch may be connected up to 3 metres away from
the unit. (This must be a volt free contact – do not wire the cable or switch
into the Mains). When the remote switch is activated, the unit will operate at
the maximum extraction rate. It will remain at this rate until the switch is
deactivated.
To pair additional remote-control switches:
- Turn the unit off at the isolation point.
- Restore power; for 20 seconds from restart the unit will be in pairing mode.
- Press the remote button once within the 20 seconds and the control will pair to the unit.
- Successful pairing is indicated by a green light on the control.
Batteries
When the battery (CR2032 type) requires changing, unscrew the switch front
cover. The battery is located on the back of the cover. The switch will remain
paired with the unit after battery replacement. Ensure the new battery is
inserted with correct polarity, and the removed battery is safely disposed of.
Optional Components
Description | Order codes |
---|---|
150mm Spigot Adaptor | 1RDSPIG150 |
Remote Pullcord | EFHTCM-RC |
External Wall Grille Kit | 1RDEFWAK |
Ceiling/Recess Mount Kit | 1ACEFCMBR |
Description | Order codes |
--- | --- |
Window Mount Kit (230V) | CYC-WIK-230V |
Window Mount Kit (SELV) | CYC-WIK-12V |
In-line Mount Kit | KITINLINEFAN |
Warranty
We appreciate you choosing this quality EnviroVent product, which is designed
and manufactured to the highest specification in Harrogate, North Yorkshire.
We are confident that you will be delighted with the performance of the system
and the resulting improvement in air quality in your home after the
installation of the unit.
The EnviroVent Cyclone 7 is covered by a full 7-year warranty which will
benefit the occupier over many years. There is no requirement for maintenance
within the first 7-year period other than general cleaning.
Your warranty covers any defect or break down that arises due to faulty
materials or construction. Please note that a receipt will be required as
proof of purchase. Units bought from an unapproved source, including but not
limited to auction websites, are not covered by this warranty.
Your fan serial number
For warranty conditions and exclusions, visit
www.envirovent.com/warranty
What should I do if I have a problem?
You should not dismantle or remove any parts of the unit other than those
instructed in this guide. Tampering with the unit will void the warranty. If
you detect a fault, please contact us on 01423 810 810.
Delivering innovative and sustainable ventilation solutions worldwide
Upon disposal, this unit and its parts should be recycled if possible. Contact your local authorities for recycling facilities and further advice.
- EnviroVent Ltd
- Harrogate West Business Park Unit 1 Bardner Bank Killinghall
- Harrogate
- HG3 2SP
- T / 01423 810 810
- E / info@envirovent.com W / envirovent.com
AFTER COMPLETING INSTALLATION, PASS THIS GUIDE ON TO THE END USER FOR FUTURE
REFERENCE
DO NOT THROW AWAY
Boxed unit weight: 2 30V: 1.65 kg SELV: 1.85 kg
Unboxed unit weight : 230V: 1.45 kg SELV: 1.25 kg
E&OE | MKT ENV897 – V3 – 02.04.24
Due to our policy of continuous innovation and improvement, EnviroVent
reserves the right to alter products specification and appearance without
notice.
We want to hear from you
Your feedback is important to us as we strive to improve our products,
services, and overall customer experience. Please email us to help us serve
you better: feedback@envirovent.com