StelPro Electric Covector User Manual
- June 8, 2024
- StelPro
Table of Contents
- IMPORTANT INSTRUCTIONS
- SPECIFICATION & TECHNICAL DRAWINGS
- TECHNICAL DRAWINGS
- INSTALLATION,ELECTRICAL CONNECTION & OPERATION
- OPERATION
- OPERATION, MAINTENACE & TROUBLESHOOTING
- IMPORTANT-LIGHT
- TROUBLESHOOTING
- TROUBLESHOOTING & REPLACEMENT COMPONENT LIST
- REPLACEMENT COMPONENT LIST
- LIMITED WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
USER’S GUIDE
ASIL SERIES
ELECTRONIC CONVECTOR
REPLACEMENT COMPONENT LIST INCLUDED
Warning
IMPORTANT INSTRUCTIONS
Before installing and operating this product, the user and/or installer must
read, understand and follow these instructions and keep them handy for future
reference. If these instructions are not followed, the warranty will be
considered null and void and the manufacturer deems no further responsibility
for this product.
This product must be installed by a qualified person and connected by a
certified electrician, according to the electrical and building codes
effective in your region.
The following instructions must be adhered to in order to avoid personal
injuries or property damages, serious injuries and potentially fatal electric
shocks. Protect the heating unit with the appropriate circuit breaker or fuse,
in accordance with the nameplate. Make sure the line voltage (volt) is
consistent with that indicated on the unit’s nameplate.
This unit must be grounded.
Switch off the power at the circuit breaker/fuse before installing, repairing,
and cleaning the unit. Make sure the unit is appropriate for the intended use
(if needed, refer to the product catalog or a representative). Use this
heater only as described in this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock, or injury to persons. Do not use
the outdoors.
Recommended heating capacity:
1.25 W/cubic foot (0.03 m³)
It corresponds to 10 W/square foot (0.09 m²) based on a standard ceiling
height of 8 feet (2.44 m). The recommended capacity is usually sufficient for
normal heating needs. Please note that the insulation quality of walls and
windows are some of the factors that influence heat losses, which modify the
required capacity to heat a room. If needed, refer to a specialist who will be
able to calculate these heat losses and optimize the required capacity or
consult the “Online heating calculation” section of the Stelpro Design Web
site (residential buildings). To heat a large room and to increase your
comfort, it is recommended to install several units instead of one. For
example, 2 X 1000 W rather than 1 X 2000 W.
Do not install the unit where objects or pieces of furniture could be heat
damaged.
If the unit’s capacity is insufficient for the size of the room, it will be in
operation continuously, and may become defective earlier and turn yellow.
Respect distances and positions indicated in the installation section.
If the installer or user modifies the unit, they will be held responsible for
any damage resulting from this modification, and the CSA certification could
be void.
This unit must not come into contact with a water source and must be protected
from splashes (e.g. a wet mop). Do not use it if any part has been immersed.
Moreover, do not turn it on or off when standing in water or if your hands are
wet.
When mounting the unit, make sure that the anchorage used can support the
total weight of the unit with the mounting brackets.
When cutting or drilling into a wall, do not damage electrical wiring and
other hidden utilities.
When starting up the unit for the first time or after a long period, it is normal that it produces some temporary odours and whitish smoke.
Because this unit is hot when in use, it may pose risks even in normal operation. Therefore, be careful and responsible when using it. To avoid burns, do not let bare skin touch hot surfaces. Let the unit cool down for a few minutes before handling it (it stays warm for some time after shut- down). Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
The bottom of this unit must be installed at least 4 inches (10.2 cm) from
any adjacent surfaces. However, make sure objects or pieces of furniture such
as, but not limited to, pillows, bedding, blankets, towels, beds, laundry
baskets, clothing, papers, curtains, etc., do not come into contact with the
unit and keep them at least 3 feet (0.9 m) from the front of the heater
and keep them away from the sides since they are more flammable than walls and
floors. Failure to comply with this warning could lead to a fire. Some
materials are more heat-sensitive than others, so make sure those near the
unit can withstand heat.
Do not install on a wall behind a door.
Never block air vents (with objects or other items). You risk damaging the
heater and the obstruction could lead to electric shock or overheating, which
could
result in a fire.
Do not insert or allow foreign objects to enter any air vent as this may cause electric shocks, a fire or damages to the unit.
This unit has hot and arcing or sparking parts inside. It is not designed to be used or stored in wet areas or areas containing flammable liquids, combustible materials or corrosive, abrasive, chemical, explosive, and flammable substances such as, but not limited to, gasoline, paint, chlorine, sawdust and cleaning products.
Some areas are dustier than others. Thus, it is the user’s responsibility to evaluate if the unit must be cleaned based on the amount of dirt accumulated on and inside air vents. Accumulated dirt can lead to a component malfunction or give a yellowish colour to unit. Failure to install and maintain unit in accordance with these instructions poses a fire hasard.
Thermal protection activation indicates that the unit has been subjected to abnormal operating conditions. If the thermal protection remains activated or activates and deactivates repeatedly, it is recommended that a qualified electrician or a certified repair centre examine the unit in order to make sure it is not damaged. (Refer to the limited warranty.)
Before unplugging the unit, all controls must be in the “OFF” position and the
current from the main breaker panel should be cut. (The general switch may be
used also, if included.) If the unit is damaged or defective, discontinue use,
cut off power supply at circuit breaker and contact a certified electrician or
certified
repair centre. (Refer to the limited warranty)
This heater includes a visual alarm to warn that parts of the heater are
getting excessively hot. If the alarm illuminates, immediately turn the heater
off and
inspect for any objects on or adjacent to the heater that may have blocked the
airflow or otherwise caused high temperatures to have occurred. DO NOT
OPE RATE THE HEATE R WITH THE ALARM ILLUMINATED .
SAVE THESE INSTRUCTIONS
Note : When a part of the product specification must be changed to improve operability or other functions, priority is given to the product specification itself. In such instances, the instruction manual may not entirely match all the functions of the actual product. Therefore, the actual product and packaging, as well as the name and illustration, may differ from the manual. The screen/LCD display shown as an example in this manual may be different from the actual screen/LCD display. This unit must be used with the provided thermostat.
SPECIFICATION & TECHNICAL DRAWINGS
SPECIFICATIONS
Add W for white, A for almond or SS for stainless steel (1000 W, 1500 W and 2000 W models only) Thermostat included
technical drawings
TECHNICAL DRAWINGS
INSTALLATION,ELECTRICAL CONNECTION & OPERATION
INSTALLATION
N.B. Cut off power supply at circuit breaker/fuse before proceeding to the
installation and wiring connections. this product must be connected by a
certified electrician, according to the electrical and building codes
effective in your region. consult the wiring plan found on the unit.
to reduce the risk of fire, do not store or use gasoline or other flammable
vapors and liquids in the vicinity of the heater. do not mount in contact with
combustible aterial. do not mount in close proximity to another unit.
DANGER – High temperatures may be generated under certain abnormal conditions. Do not partially or fully cover or obstruct the front of this heater.
INSTALLATION OF THE WALL RACK
1. Remove the unit from the wall rack’s hooks.
2. With a pencil, mark the wall at the four anchoring points of the rack.
3. Fasten the rack to the wall, making sure it is level. When drilling into a
wall or ceiling, be careful not to damage electrical wiring and other hidden
utilities.
N.B. the wall on which the convector will be installed must be straight in
order for the wall rack to lie perfectly
flat without any pressure points. otherwise, brackets could malfunction.
INSTALLATION OF THE UNIT TO THE WALL RACK
- Insert the bottom hooks of the rack into the unit.
- Tip the top of the unit toward the wall.
- Latch the unit onto the rack by pressing towards the wall.
ELECTRICAL CONNECTION
This unit must be connected by a certified electrician. Connect the bare wire
(ground) to the green wire of the unit. Connect wires from the electrical box
to the unit’s supply leads.
N.B. this product must be connected by a qualified electrician, according
to the electrical and building codes effective in your region.
OPERATION
Warning: the heater must be properly installed before it is used.
WITH A BUILT-IN ELECTRONIC THERMOSTAT
TEMPERATURE CONTROL AND DISPLAY
The thermostat has two modes: the DAY mode, identified on the digital screen
by a SUN icon and the NIGHT mode, identified by a MOON icon. To switch from
one mode to the other, simultaneously press down both buttons once.
N.B. When you select the night mode, the thermostat will respond
accordingly for the duration of the time preprogrammed for this mode (see
“selection of the duration of the night mode”). When the preprogrammed time
has passed, the thermostat will automatically return to the day mode.
THE NORMAL DISPLAY WILL CONTINUOUSLY INDICATE:
– the current mode icon ( or );
– the ANTIFREEZE mode icon ( ), (if applicable, see “Antifreeze Protection”);
– the LOCK icon ( ), (if applicable, see “Lock option”);
– the automatic mode icon ( ), (if applicable, see “Automatic Mode”);
– the ambient temperature of the room;
– the selected temperature scale (°C or °F).
BUTTON FUNCTIONS
OPERATION
DAY MODE
HOW TO SET THE DAY TEMPERATURE
By pressing down the top or bottom button, you will enter the setting mode
indicated by the flashing SUN icon. This way, you can see the DAY temperature
setting.
You can change the temperature with these same buttons by increasing (top
button) or decreasing (bottom button) the set point. The temperature set point
will increase or decrease by increments of 0.5 °C (or 1 °F) each time you
press down a button. If you hold down the button, the temperature will quickly
scroll through, allowing a faster and more efficient setting.
Once the temperature is set, release the button; normal display will resume
after three (3) seconds.
NIGHT LIGHT MODE
Normally, the backlight is activated when you press down the button, and stays on for fifteen (15) seconds afterwards. To keep the backlight on, simultaneously press down both buttons for 3 seconds (until the backlight blinks), then release. Repeat this procedure to deactivate the night light mode.
SELECTION OF THE TEMPERATURE SCALE
To change the temperature scale (°C or °F), simultaneously press down both buttons for eight (8) seconds, the °C or °F symbol will blink. Release the buttons to set the new scale (note that the backlight will blink after 3 seconds).
LOCK OPTION
It is possible to impose a maximum temperature set point by activating this mode. Then, it becomes impossible to exceed this set point, regardless of the current mode (DAY/NIGHT). However, it is still possible to lower the temperature at your discretion. All the other functions remain unchanged. For increased security, the power supply needs to be cut off in order to deactivate the lock.
LOCKING PROCEDURE
1. From the DAY mode, adjust the set point to the maximum desired value.
2. Simultaneously press down both buttons for more than 13 seconds, until the
LOCK icon is displayed (note that the backlight will blink after 3 seconds and
the °C and °F symbols, after 8 seconds).
3. Release the buttons. The thermostat is now locked.
UNLOCKING PROCEDURE
1. Cut off the power supply of the thermostat at the electrical panel.
2. Wait about 1 minute.
3. Restore the power supply of the thermostat at the electrical panel.
4. The LOCK icon blinks on the thermostat display, meaning that it is
possible to unlock the thermostat.
5. While the LOCK icon is blinking, simultaneously press down both buttons
for more than 10 seconds, until the LOCK icon disappears.
6. release the arrows. The thermostat is now unlocked.
N.B. if the thermostat is not unlocked within 5 minutes after
restoring the power supply, the Lock icon will stop blinking and
it will be impossible to unlock the thermostat without cutting off
the power supply again.
NIGHT MODE
HOW TO SET THE NIGHT TEMPERATURE
By pressing down the top or bottom button, you will enter the setting mode indicated by the flashing MOON icon. This way, you can see the NIGHT temperature setting.
You can change the temperature with these same buttons by increasing (HIGH button) or decreasing (LOW button) the set point. The temperature set point will increase or decrease by increments of 0.5 °C (or 1 °F) each time you press a button. If you hold down the button, the temperature will quickly scroll through, allowing a faster and more efficient setting. Once the temperature is set, release the button; normal display will resume after three (3) seconds.
SELECTION OF THE DURATION OF THE NIGHT MODE
By simultaneously pressing down both buttons for three (3) seconds, you will
be able to program the desired duration of the NIGHT mode. You can decrease or
increase the number of hours (1 to 999 hours). If you hold down the button,
the hours will quickly scroll through allowing a faster setting. Normal
display will resume three (3) seconds after releasing the button.
Therefore, you can regulate the unit according to your specific needs. For
example, to save energy and increase comfort at night, you can set the number
of hours so that the unit automatically switches to DAY mode when you awake
(see “Automatic Mode”). Furthermore, if you are going away for some time and
wish to save energy during your absence without having to come back to an
uncomfortable room, simply indicate the number of hours you will be absent (1
day = 24 hours, 1 week = 168 hours). by setting the NIGHT mode this way before
leaving, the temperature will automatically switch back to DAY mode upon your
return, thus ensuring optimal comfort.
AUTOMATIC MODE
To activate or deactivate this mode, you must switch to the “Selection of the
Duration of the NIGHT Mode”. The number of programmed hours must be 23 or less
to activate the AUTOMATIC mode. To activate it, simultaneously press down both
buttons for three (3) seconds. To deactivate this mode, simultaneously press
down both buttons again for three (3) seconds. If the number of programmed
hours is increased to more than 23, the AUTOMATIC mode will immediately be
deactivated (if it was activated). The AUTOMATIC mode icon lights on or off as
applicable.
If you do not press down any button for five (5) seconds, you exit the
programming mode and return to the NIGHT mode, the programming of the NIGHT
mode is re-initialized and the AUTOMATIC mode becomes effective (if it was
activated). After 24 hours, the thermostat returns to the NIGHT mode
automatically.
Then, the night programming is re-initialized and another 24 hours cycle
starts. even if the thermostat is in AUTOMATIC mode, you can switch from DAY
mode to NIGHT mode at your discretion, it will not impact the 24 hours cycle
or the automatic return of the NIGHT mode.
N.B. activation of the off mode deactivates the automatic mode.
When power is restored (after a power failure for example), the AUTOMATIC mode
is deactivated. If it was activated before the power down, the AUTOMATIC mode
icon blinks. Then, the thermostat will be in DAY mode. The blinking will cease
as soon as you press down a button.
PRECISE ELECTRONIC CONTROL
A chrono-proportional electronic thermostat controls this unit with a high
degree of accuracy in order to minimize temperature differences and increase
your comfort level. It allows very stable temperature and ensures uniform
comfort. It also keeps the casing at a low temperature, making it more secure.
The chrono-proportional electronic thermostat entirely regulates the unit by
increasing or decreasing the heating cycle percentage according to the
selected temperature. Please note that the unit becomes warmer if the heating
demand is higher and that it remains mildly warm when the demand is lower.
N.B. if the unit is set on high or if it is not functioning at all, the
temperature gage of the thermostat sensor cannot take a precise reading.
however, the reading becomes extremely precise once the heating level has
stabilized. therefore, uniform convection increases the precision of the
thermostat.
OPERATION, MAINTENACE & TROUBLESHOOTING
In order to obtain a precise and optimal ambient temperature reading, the unit must operate on a regular basis, i.e. without significant temperature variation for at least an hour. (This amount of time increases if a temperature change of more than 4 degrees is requested. Add approximately 15 minutes for every degree above 4).
ANTIFREEZE PROTECTION
In order to protect your home against freezing and limit energy consumption during long absences, put the thermostat on ANTIFREEZE mode. To enter this mode, lower the day temperature to between 3°C and 5°C. A snowflake icon ( ) is displayed. This icon indicates that the economic and secure ANTIFREEZE mode is on.
THE OFF MODE
To turn the unit off, you must lower the day temperature to less than 3°C. The inscription “OFF” is displayed (note that there is still electrical current to the unit, meaning that there is a risk of electrical shock).
WITH AN ELECTRONIC WALL THERMOSTAT
This unit has been designed to be used with the electronic wall thermostat included in the box.
PRECISE ELECTRONIC CONTROL
Equipped with a proportional tension variation, the thermostat maintains a precise temperature, thus increasing your comfort level. The elimination of temperature fluctuations combined with the use of the programmed heat lowering function (PT model) allows for energy savings.
COMPLETE FACTORY INSTRUCTION FOR TE AND PT THERMOSTATS ARE INCLUDED IN THEIR RESPECTIVE PACKAGING
IMPORTANT-LIGHT
Activation of the thermal protection is indicated by a light located at the right end, visible trough the louvers. It warns you that the heater has been subjected to abnormal conditions. If this occurs, it is highly recommended that the unit be disconnected and inspected by a qualified electrician in order to make sure it is not damaged.
MAINTENANCE
All other repairs and maintenance other than those described in this guide should be performed by qualified service personnel. in order for the warranty to be valid, the unit must be cleaned regularly. cut off power supply at circuit breaker/fuse and wait for the unit to cool down before cleaning.
Use a soft rag for dusting. When cleaning, use only a damp rag and non- abrasive dish soap. Do not use abrasive or chemical cleaners because they may damage the finishing. If the unit is used in a very dusty location, use a vacuum brush to remove dust and other foreign objects from the grilles. Note that cigarette smoke could yellow the discharge grille and that the best way to prevent it is to clean the unit on a regular basis.
Do not use cleaning products identified with these symbols:
N.B. note that there is electrical current linked to the unit even if the thermostat is set off. this means that there is a risk of electric shock as long as the unit is energized.
STAINLESS STEEL CLEANING TIPS
Although stainless steel is, by its very nature, corrosion resistant, its finish is not foolproof. The key to maintaining a nice stainless steel finish is preventive cleaning. Clean the metal when it is dirty; do not wait until a full cleaning is required. Since the acidity level and the chlorine content of regular cleaning agents vary greatly, it is highly recommended to thoroughly rinse the surface with clean water. Alternatively, you can use a stainless steel cleaner or clean water and dish soap. Always follow polish lines.
DO NOT USE
– chlorine
– scrubbing pads or similar scrubbing devices (steel wool)
– abrasive cleaning agents
– hydrochloric acid products such as bleach: they can stain and/or damage
stainless steel surfaces
TROUBLESHOOTING
TROUBLESHOOTING & REPLACEMENT COMPONENT LIST
N.B. if you do not solve the problem after checking these points, cut off
the power supply at the main electrical panel and contact our
customer service (please refer to the limited warranty to obtain the phone
numbers)
REPLACEMENT COMPONENT LIST
- Add W for white, A for almond, SS for stainless steel
LIMITED WARRANTY
This limited warranty is offered by Stelpro Design inc. (“Stelpro”) and applies to the following product made by Stelpro: ASIL model. please read this limited warranty carefully. Subject to the terms of this warranty, Stelpro warrants its products and their components against defects in workmanship and/or materials for the following periods from the date of purchase: 5 years (3 years on electronic components). This warranty applies only to the original purchaser; it is non-transferable and cannot be extended.
CLAIM PROCEDURE
If at any time during the warranty period the unit becomes defective, you must cut off the power supply at the main electrical panel and contact 1) your installer or distributor, 2) your service center or 3) Stelpro’s customer service department. In all cases, you must have a copy of the invoice and provide the information written on the product nameplate. Stelpro reserves the right to examine or to ask one of its representatives to examine the product itself or any part of it before honoring the warranty. Stelpro reserves the right to replace the entire unit, refund its purchase price or repair a defective part. Please note that repairs made within the warranty period must be authorized in advance in writing by Stelpro and carried out by persons authorized by Stelpro.
Before returning a product to Stelpro, you must have a Stelpro authorization number (RMA). To obtain it, call the customer service department at: 1-800-363- 414 (electricians and distributors – French), 1-800-343-1022 (electricians and distributors – English), or 1-866-766-6020 (consumers). The authorization number must be clearly written on the parcel or it will be refused.
CONDITION EXCLUSIONS AND DISCLAIMER LIABILITY
This warranty is exclusive and in lieu of all other representations and
warranties (except of title), expressed or implied, and Stelpro expressly
disclaims and excludes any implied warranty of merchantability or implied
warranty of fitness for a particular purpose.
Stelpro’s liability with respect to products is limited as provided above.
Stelpro shall not be subject to any other obligations or liabilities
whatsoever, whether based on contract, tort or other theories of law, with
respect to goods or services furnished by it, or any undertakings, acts or
omissions relating thereto. Without limiting the generality of the foregoing,
Stelpro expressly disclaims any liability for property or personal injury
damages, penalties, special or punitive damages, damages for lost profits,
loss of use of equipment, cost of capital, cost of substitute products,
facilities or services, shutdowns, slowdowns, or for other types of economic
loss or for claims of a dealer’s customers or any third party for such
damages. Stelpro specifically disclaims all consequential, incidental and
contingent damages whatsoever.
This warranty does not cover any damages or failures resulting from: 1) a
faulty installation or improper storage; 2) an abusive or abnormal use, lack
of maintenance, improper maintenance (other than that prescribed by Stelpro)
or a use other than that for which the unit was designed; 3) a natural
disaster or an event out of Stelpro’s control, including, but not limited to,
hurricanes, tornadoes, earthquakes, terrorist attacks, wars, overvoltage,
flooding, water damages, etc. This warranty does not cover any accidental or
intentional losses or damages, nor does it cover damages caused by negligence
of the user or owner of the product. Moreover, it does not cover the cost of
disconnection, transport, and installation.
The warranty is limited to the repair or the replacement of the unit or the
refund of its purchase price, at the discretion of stelpro. Any parts
replaced or repaired within the warranty period with the written authorization
of Stelpro will be warranted for the remainder of the original warranty
period. This warranty ill be considered null and void and Stelpro will have
the right to refuse any claims if products have been altered without the
written authorization of Stelpro and if the nameplate numbers have been
removed or modified. This warranty does not cover scratches, dents, corrosion
or discoloration caused by excessive heat, chemical cleaning products and
abrasive agents. It does not cover any damage that occurred during the
shipping.
Some states and provinces do not allow the exclusion or limitation of
incidental or consequential damages and some of them do not allow limitations
on how long an implied warranty lasts, so these exclusions or limitations may
not apply to you. This warranty gives you specific legal rights and you may
have other rights which vary from state to state or from province to province.
StelPro Electric Covector User Manual – Download
[optimized]
StelPro Electric Covector User Manual – Download
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>