PHILIPS DreamStation 2 Auto CPAP Advanced User Manual
- June 7, 2024
- Philips
Table of Contents
- PHILIPS Dream Station 2 Auto CPAP Advanced User Manual
- Evolving to a new way of doing business
- Philips Dream Station 2 Auto CPAP Advanced Success. By design.
- Patient setup and training
- Introducing Dream Station 2 Auto CPAP Advanced
- Device components
- Ordering information
- Dream Station 2 Auto CPAP Advanced
- Dream Station 2 Auto CPAP and
- VIDEO
- FAQS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PHILIPS Dream Station 2 Auto CPAP Advanced User Manual
PHILIPS Dream Station 2 Auto CPAP Advanced
Evolving to a new way of doing business
The business of treating patients for obstructive sleep apnea (OSA) is more
complex than ever. The need to minimize personal contact and increase
connectivity has led to the
heightened importance of home delivery. There is a clear need for simplified,
low-touch solutions that help you get patients started on sleep therapy
quickly, safely and comfortably while continuing to grow your business.
Philips Dream Station 2 Auto CPAP Advanced provides a streamlined user
experience for enhanced operational efficiencies in setup times and training,
patient initiation and patient management.
Philips Dream Station 2 Auto CPAP Advanced Success. By design.
Simplified. Intuitive. Connected.
Dream Station 2 Auto CPAP Advanced is designed to help you and your patients
succeed…together.
Patient setup and training
Efficient setup: Flexibility in the setup process allows you to choose what is best for your business.
-
Out-of-the-box, no-touch setup1
• Accept data-driven defaults
• Personalize remotely with Care Orchestrator -
Streamlined, low-touch, first-ever guided setup on the device
Simplified training: The CPAP features intuitive navigation of comfort features and settings, along with easy handling of the device. Precision mask fitting: Philips Respironics Mask Selector uses no-touch scanning technology for the right mask fit from the start.2
RTs set up Dream Station 2 Auto CPAP Advanced 28.7% faster than Dream Station on first try.3
Initiation
Three easy-to-access comfort settings: Patients can make live adjustments of Ramp Plus, humidification and heated tube temperature while therapy is running.
- Ramp Plus allows patients to set a comfortable starting pressure for falling asleep, which may also help reduce callbacks and adjustments to minimum
pressure prescriptions.
Micro-flexible 12mm heated tube: Philips smallest-diameter tubing is designed
to be comfortable while taking up less space than traditional tubing.
Smart auto and advanced algorithms: Proprietary algorithms automatically
adjust pressure to provide personalized therapy and treat AHIs at lower
pressures.4
Ongoing compliance
Enhanced connectivity: Integrated cell modem with simplified Bluetooth pairing enables remote setup and easy access to data for both your care team and your patients.
- On-demand prescription changes
- Remote troubleshooting through Performance Check
Philips Care Orchestrator: Drive collaboration among your team with patient insights delivered straight to smartphones, tablets or PCs.
- Adherence Profiler enables you to get notifications if a patient is at risk of noncompliance in a 90-day period.
Dream Mapper app keeps patients engaged with easy access to coaching to drive ongoing complian ce.
Patients struggling with adherence to sleep therapy have a 283% higher success rate .5
Introducing Dream Station 2 Auto CPAP Advanced
Device components
Ordering information
Dream Station 2 Auto CPAP Advanced part numbers
Part Number | Description (Package Label) |
---|---|
DSX520H11C | Dream Station 2 Auto CPAP Advanced + Humidifier with cell/BT |
DSX520T11C | Dream Station 2 Auto CPAP Advanced + Humidifier/Heated Tube |
with cell/BT
Dream Station 2 Auto CPAP Advanced
Part Number | Description (Package Label) |
---|---|
1146072 | DS2 Humidifier Water Tank No Lid, RP |
1146073 | DS2 Humidifier Lid only, RP |
1142832 | DS2 Water Tank with Lid |
1142836 | DS2 Inlet/Outlet Seal, RP |
1142687 | DS2 Reusable Pollen Filter, RP – 1 pack |
1142828 | DS2 Disposable Ultra-Fine Filter, RP – 1 pack |
1142829 | DS2 Disposable Ultra-Fine Filter, RP – 2 pack |
1142831 | DS2 Disposable Ultra-Fine Filter, RP – 6 pack |
1144877 | 3150 BLE Wrist Ox |
1147077 | Soft Reusable Finger Sensor, WristOx, SM |
1147178 | Soft Reusable Finger Sensor, WristOx, M |
1147179 | Soft Reusable Finger Sensor, WristOx, L |
1147180 | PC USB Interface Cable, WristOx 3150 BLE |
1142834 | DS2 Carrying Case |
1145156 | DS2 Roll Stand |
Dream Station 2 Auto CPAP and
Dream Station 2 Auto CPAP Advanced
Part Number | Description (Package Label) |
---|---|
HT15 | 15 mm Heated Tube |
PR15 | 15 mm Standard Tube – Dream Station |
PR12 | 12 mm Micro-Flexible Tube – Dream Station |
HT12 | 12 mm Micro-Flexible Heated Tube |
1032907 | 22 mm Performance Tube |
1147466 | 12 mm Tube Device Adapter with OIS – Dream Station |
1128074 | 12 mm Mask Adapter |
1145085 | Philips RI SD Card – 1 pack |
1063859 | Philips RI SD Cards – 10 pack |
1120747 | Shielded DC Cord System – Dream Station |
1144267 | Philips 80W CPAP Power Supply |
1038928 | Power Cord with C7 End USA/CAN 5 FT |
532209 | DC Battery Adapter Cable |
1124009 | PAP Lithium Ion Battery Kit |
1121736 | Lithium Ion Battery, PAP Device Cable |
1126947 | Lithium Ion Battery Case |
342077 | Bacteria Filter |
302418 | Pressure Valve |
1038928 | Power Cord with C7 End USA/CAN 5 FT |
312710 | O2 Enrichment Attachment |
References:
-
Assumes acceptance of smart, default settings. Alternatively, you can set up prescriptions entirely via CO with no device touch.
-
Data analysis after 90 days of use.
2019 Philips sponsored patient preference trial (n=310). Patient scanned using the Mask Selector (n=153) vs. Traditional fitting methods (n=157). -
Philips randomized usability trial. Ease-of-Set Up and Time-to-Set Up of Continuous Positive Airway Pressure (CPAP) Devices; evaluating the user interface with 27 respiratory
therapists that typically set up Philips DreamStation and ResMed AirSense 10 CPAP devices. 2020. -
Hertegonne KB, Rombaut B, Houtmeyers P, Van Maele G, Pevernagie
DA. Titration efficacy of two auto-adjustable continuous positive airway pressure devices using different flow limitation-based algorithms. Respiration. 2008;75(1):48-54. doi:
10.1159/000103515. Epub 2007 Jun 1. PMID: 17541262. Nolan GM, Ryan S, O’Connor TM, McNicholas WT. Comparison of three auto-adjusting positive pressure devices in patients
with sleep apnoea. Eur Respir J. 2006 Jul;28(1):159-64. doi: 10.1183/09031936.06.00127205. Epub 2006 Mar 29. PMID: 16571610. Nieves Navarro Soriano, Mikel Azpiazu Blocona,
Javier Carrillo Hernández-Rubio, Raquel Cobos Campos, Ainhoa Alvarez Ruiz de Larrinaga, Bereniç Murià Diaz David Diez Fuente, Carlos Javier Egea Santaolalla. The Effective
Pressure of the CPAP Titration Depends on the APAP Device Used. Poster at SEPAR Convention (Spain). May 2018. Javier Carrillo Hernandez-Rubio, Mikel Azpiazu Blocona,
David Diez Fuente, Nieves Berlen Navarro Soriano, Laura Cancelo Diaz, Lourdes Guerra Martin, Raquel Cobos Campos, Carlos Javier Egea Santaolalla. Validity of the CPAP
Automatic Titration in our Sleep Unit. Poster at SEPAR Convention (Spain). May -
- 46% of DreamMapper patients went on to achieve adequate adherence
within 90 days
versus 12% for the Standard Care group, a relative increase of 283.33%. In a retrospective review conducted by Philips Respironics of the EncoreAnywhere database (white paper)
of struggling patients (n=24,176).
- 46% of DreamMapper patients went on to achieve adequate adherence
within 90 days
VIDEO
FAQS
What Are the Features and Benefits of the Dream Station 2?
he Dream Station 2 Auto CPAP, a clinically-proven integrated sleep solution, features advanced comfort features designed to enhance your ease of use. Whether you’re shopping for your first CPAP machine or have been diagnosed with sleep apnea for a while and simply want a new CPAP set-up, the Dream Station 2 is, well, a dream.
Is the Dream Station 2 part of the recall?
On Sept. 1, Philips announced that it had received authorization from the FDA to begin its repair and replacement programs for recalled devices. The sound abatement foam in recalled devices will be replaced with a new material. The company also is replacing some Dream Station CPAP devices with Dream Station 2 devices.
What is the difference between Philips Dream Station and Dream Station 2?
The Dream Station 2 Auto CPAP Advanced Machine is 29% smaller and 32% lighter than the original model. Weighing in at roughly 2.3 pounds, this machine takes up minimal space on the nightstand. It can also be conveniently packed in luggage or a carry-on to bring while traveling.
Does Dream Station 2 automatically adjust pressure?
Those new to CPAP can struggle to adapt to prescribed pressure settings, but the new Ramp Plus feature is designed to ease you into your sleep therapy at a lower, more comfortable pressure setting while you drift to sleep. After 30 minutes, the Dream Station 2 will make automatic adjustments to meet your pressure needs.
Can you use the Dream Station 2 without the humidifier?
Dream Station 2’s humidification seamlessly attaches with the rest of the device. Although it comes apart in various pieces, you cannot actually disconnect the entire humidifier and use main unit independently. Unlike it’s predecessor, you can only turn the humidifier off if you choose not to use it.
Does Dream Station 2 Use same filters as Dream Station?
They are original Philips Respironics branded filters compatible with all Dream Station 2 CPAP & BiLevel machines. Foam Pollen Filters, from Philips Respironics, are required for use with all Dream Station 2 CPAP & BiPAP machines.
Can you use So Clean with Dream Station 2?
Adapter for Philips Respironics Dream Station 2 to ensure compatibility with So Clean 2 CPAP Cleaner. This kit includes one So Clean Express Adapter and two 12mm Hose Sleeves. The adapter is necessary to connect the Philips Respironics Dream Station 2 to your So Clean.
Is So Clean being recalled?
The use of an ozone cleaner such as the So Clean can make this worse. While the number of people actually experiencing problems has been quite small, there is enough concern to trigger this recall.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>