DEVIreg 330 Thermostat -10 to +10c Installation Guide
- June 16, 2024
- DEVI
Table of Contents
DEVIreg 330 Thermostat -10 to +10c
Specifications
-
Operation voltage: 220-240 V~, 50 Hz
-
Standby power consumption: Max 0.25 W
-
Relay: Resistive load Max 16 A / 3680 W @ 230 V, Inductive load
max1A -
Sensing units: 42 kOhm, 15 kOhm, 6 kOhm
-
Hysteresis: 0.05 – 0.18
-
Temperature range: 20-40°C
-
Cable specification max: 1×4 mm2 or 2×2.5 mm2
-
Pollution degree: 2 (domestic use)
-
Type: 1C
-
Storage temperature: -20°C
-
IP class: Class II
-
Dimensions: 86 x 36 x 58 mm
-
Weight: 83 g
Product Usage Instructions
1. Introduction
The DEVIregTM 330 is an electronic thermostat designed for electric cabinets with DIN rail attachment. It requires installation via an all-pole disconnection switch. To measure and control the desired temperature, either a floor sensor or an external room sensor must be used. For more information on this product, visit devireg.devi.com.
2. Mounting Instructions
Follow the steps below to mount the thermostat:
-
1. Click the thermostat onto the DIN rail attachment.
- Connect the thermostat according to the connection diagram.
Connection Diagram:
The screen of the heating cable must be connected to the earth conductor of the power supply cable using a separate connector.
Note: When using the wire sensor for floor heating, always install the sensor in a conduit.
- Turn on the power supply.
3. Settings
If a floor sensor is used, please be aware of the following:
- For 8 mm HDF-based laminate, set hysteresis to 0.05.
- For 14 mm beech parquet, set hysteresis to 0.10.
- For 22 mm solid oak plank, set hysteresis to 0.13.
- For carpet thickness suitable for floor heating up to 22 mm solid fir planks, set hysteresis to <0.17.
4. Warranty
A 2-year product warranty is valid for:
- Faulty products due to defective design, materials, or workmanship. The decision to repair or replace the product will be at the discretion of Danfoss, and no extension of the warranty period following repairs undertaken is granted. Danfoss shall not be liable for any consequential or incidental damages.
FAQ
Q: How long is the warranty period for the DEVIregTM 330 thermostat?
A: The warranty period for the DEVIregTM 330 thermostat is 2 years from the date of purchase.
Q: Can I use the thermostat without a floor sensor or external room sensor?
A: No, either a floor sensor or an external room sensor must be used to measure and control the desired temperature.
Introduction
DEVIreg™ 330 is an electronic thermostat to be installed in electric cabinets
with DIN rail attachment. The thermostat must be installed via an all-pole
disconnection switch. Either a floor sensor or an external room sensor must be
used to measure and control the desired temperature.
The thermostat has a button to adjust the temperature setting with a scale
from +5 to +45°C. An LED indicator shows standby periods (green light) and
heating periods (red light). More information on this product can also be
found at:
Technical Specifications
Operation voltage | 220-240 V~, 50 Hz |
---|---|
Standby power consumption | Max 0,25 W |
Relay:
Resistive load Inductive load
| ****
Max 16 A / 3680 W @ 230 V
cos φ= 0,3 max1A
Sensing units| NTC 15 kOhm at 25 °C
Sensing values:|
0 °C| 42 kOhm
25 °C| 15 kOhm
50 °C| 6 kOhm
Hysteresis| ± 0,2 °C
Ambient temperature| 10 °C to +50 °C
Lowering in economy periods| -5 °C
Temperature range| +5 °C to +45 °C
Cable specification max| 1×4 mm2 or 2×2,5 mm2
Ball pressure temperature| 75 °C
Pollution degree| 2 (domestic use)
Type| 1C
Storage temperature| -20 °C to +65 °C
IP class| 20
Protection class| Class II
---|---
Dimensions| 86 x 36 x 58 mm
Weight| 83 g
The product complies with the EN/IEC Standard “Automatic electrical controls for household and similar use”:
- EN/IEC 60730-1 (general)
- EN/IEC 60730-2-9 (thermostat)
Safety Instructions
Make sure the mains supply to the thermostat is turned off before installation.
IMPORTANT: When the thermostat is used to control a floor heating element
in connection with a wooden floor or similar material, always use a floor sensor
and never set the maximum floor temperature to more than 35°C.
Please also note the following:
- The installation of the thermostat must be done by an authorized and qualified installer according to local regulations.
- The thermostat must be connected to a power supply via an all-pole disconnection switch.
- The sensor is to be considered as live voltage. Have this in mind if the sensor must be extended.
- Always connect the thermostat to the continuous power supply.
- Do not expose the thermostat to moisture, water, dust, and excessive heat.
Mounting Instructions
Please observe the following placement guidelines:
- Install the thermostat in an electric cabinet with DIN rail attachment or a separate DIN attachment according to local regulations on IP classes.
- Do not place the thermostat in a way that it will be exposed to direct sunlight.
Follow the steps below to mount the thermostat:
-
Click the thermostat on to the DIN rail attachment.
-
Connect the thermostat according to the connection diagram. The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector.
Note: When you use the wire sensor for floor heating, always install the sensor in a conduit. -
Turn on the power supply.
Settings
If a floor sensor is used, please be aware of the following:
- The floor temperature is measured where the sensor is placed.
- The temperature of the bottom of a wooden floor can be up to 10 degrees higher than the top.
- Floor manufacturers often specify the max temperature on the top surface of the floor (usually 27-28˚C).
- Always use a floor sensor to control floor heating. Without a floor sensor, the temperature control may be less accurate and you risk overheating the floor.
Thermal resist- ance [m²K/W]| Examples of flooring| Details|
Approximate setting for 25˚C floor temperature
---|---|---|---
0,05| 8 mm HDF-based laminate| > 800 kg/m³| 28˚C
0,10| 14 mm beech parquet| 650 – 800 kg/m³| 31˚C
0,13| 22 mm solid oak plank| > 800 kg/m³| 32˚C
< 0,17| Max. carpet thickness suitable for floor heating| acc. to EN 1307|
34˚C
0,18| 22 mm solid fir planks| 450 – 650 kg/m³| 35°C
Warranty
A 2-year product warranty is valid for:
- thermostats: DEVIreg™ 330 (+5 to +45° C).
Should you, against all expectations, experience a problem with your DEVI
product, you will find that Danfoss offers DEVIwarranty valid from the date of
purchase on the following conditions: During the warranty period Danfoss shall
offer a new com-parable product or repair the product if the product is found
to be faulty by reason of defective design, materials or workmanship. The
repair or replacement. The decision to either repair or replace will be solely
at the discretion of Danfoss. Danfoss shall not be liable for any
consequential or incidental damages including, but not limited to, damages to
property or extra utility expenses. No extension of the warranty period
following repairs undertaken is granted. The warranty shall be valid only if
the WARRANTY CERTIFICATE is completed correctly and in accordance with the
instructions, the fault is submitted to the installer or the seller without
undue delay and proof of purchase is provided. Please note that the WARRANTY
CERTIFICATE must be filled in, stamped and signed by the authorized installer
performing the installation (Installation date must be indicated). After the
installation is performed, store and keep the WARRANTY CERTIFICATE and
purchase documents (invoice, receipt or similar) during the whole warranty
period. DEVIwarranty shall not cover any damage caused by incorrect conditions
of use, incorrect installation or if installation has been carried out by non-
authorized electri-cians. All work will be invoiced in full if Danfoss is
required to inspect or repair faults that have arisen as a result of any of
the above. The DEVIwarranty shall not extend to products which have not been
paid in full. Danfoss will, at all times, provide a rapid and effective
response to all complaints and inquiries from our customers. The warranty
explicitly excludes all claims exceeding the above conditions.
For full warranty text
WARRANTY CERTIFICATE
Disposal Instruction
Danfoss A/S Nordborgvej 81 6430 Nordborg, Syddanmark Denmark
Any information, including, but not limited to information on selection of product, its application or use, product design, weight, dimensions, capacity or any other technical data in product manuals, catalogues descriptions, advertisements, etc. and whether made available in writing, orally, electronically, online or via download, shall be considered informative, and is only binding if and to the extent, explicit reference is made in a quotation or order confirmation. Danfoss cannot accept any responsibility for possible errors in catalogues, brochures, videos and other material. Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to form, fit or function of the product. All trademarks in this material are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.
- 220-240V~
- 50-60Hz~
- +5 to +45°C
- 16A/3680W@230V~
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>