diagram

Pinout

Table 1 FMB130 2×6 socket pinout

PIN NUMBER PIN NAME DESCRIPTION
1 VCC (10-30) V DC (+) Power supply (+10-30 V DC).
2 DOUT 3 Digital output, channel 3. Open collector output. Max. 0,5 A DC..
3 DIN 3 / AIN 2 Analog input, channel 2. Input range: 0- 30 V DC / Digital

input, channel 3.
4| DIN 2-N / AIN 1| Digital input, channel 2, Negative input, Analog input, channel 1, Input range: 0- 30 V DC.
5| DIN 1| Digital input, channel 1.
6| INPUT 6| TX EXT (LVCAN – TX).
7| GND (-)| Ground pin. (10-30) V DC (―)
8| DOUT 1| Digital output, channel 1. Open collector output. Max. 0,5 A DC..
9| DOUT 2| Digital output, channel 2. Open collector output. Max. 0,5 A DC.
10| 1WIRE POWER| +3,8 V output for 1–Wire devices.
11| 1WIRE DATA| Data for 1–Wire devices.
12| INPUT 5| RX EXT (LVCAN – RX).

Wiring scheme

diagram

Set up your device

How to insert Micro-SIM card and connect the battery

  1. Gently remove FMB130 bottom cover using plastic pry tool from both sides. Then remove the top cover.
    diagram, engineering drawing

  2. Insert Micro-SIM card as shown with PIN request disabled or read our Wiki how to enter it later in Teltonika Configurator.
    Make sure that Micro-SIM card cut-off corner is pointing forward to slot.
    diagram, engineering drawing

  3. Connect battery as shown to device. Position the battery in place where it does not obstruct other components.
    diagram, engineering drawing

  4. After configuration, see “PC Connection (Windows)”, attach device top and bottom cover back.
    diagram, engineering drawing

PC Connection (Windows)

  1. Power-up FMB130 with DC voltage (10 – 30 V) power supply using supplied power cable. LED’s should start blinking, see “LED indications”.

  2. Connect device to computer using Micro-USB cable or Bluetooth connection:
    • Using Micro-USB cable
    ▬ You will need to install USB drivers, see “How to install USB drivers (Windows)”
    • Using Bluetooth
    ▬ FMB130 Bluetooth is enabled by default. Turn on Bluetooth on your PC, then select Add Bluetooth or other device > Bluetooth. Choose your device named – “FMBxxx_last_7_imei_digits”, without LE in the end. Enter default password 5555, press Connect and then select Done.

  3. You are now ready to use the device on your computer.

How to install USB drivers (Windows)

  1. Please download COM port drivers from here.
  2. Extract and run TeltonikaCOMDriver.exe.
  3. Click Next in driver installation window.
  4. In the following window click Install button.
    Setup will continue installing the driver and eventually the confirmation window will appear. Click Finish to complete the setup.

Configuration (Windows)

At first FMB130 device will have default factory settings set. These settings should be changed according to the user’s needs. Main configuration can be performed via Teltonika Configurator software. Get the latest Configurator version from here.
Configurator operates on Microsoft Windows OS and uses prerequisite MS .NET Framework. Make sure you have the correct version installed.

Table 2 MS .NET requirements

MS .NET REQUIREMENTS

Operating system| MS .NET Framework version| Version| Links
Windows Vista Windows 7
Windows 8.1
Windows 10| MS .NET Framework 4.6.2|

32 and 64 bit

|

www.microsoft.com

Downloaded Configurator will be in compressed archive. Extract it and launch Configurator.exe. After launch software language can be changed by clicking icon in the right bottom corner ( Figure 8 Language selection).
graphical user interface, text, application

Configuration process begins by pressing on connected device (Figure 9 Device connected via USB).
graphical user interface, text, application
After connection to Configurator Status window will be displayed
( Figure 10 Configurator Status window ).
graphical user interface

Various Status window tabs display information about GNSS, GSM, I/O, Maintenance and etc. FMB130 has one user editable profile, which can be loaded and saved to the device. After any modification of configuration the changes need to be saved to device using Save to device button. Main buttons offer following functionality:

  1. Load from device – loads configuration from device.
  2. Save to device – saves configuration to device.
  3. Load from file – loads configuration from file.
  4. Save to file – saves configuration to file.
  5. Update firmware – updates firmware on device.
  6. Read records – reads records from the device.
  7. Reboot device – restarts device.
  8. Reset configuration – sets device configuration to

Most important configurator section is GPRS – where all your server and GPRS settings can be configured and Data Acquisition – where data acquiring parameters can be configured.
More details about FMB130 configuration using Configurator can be found in our Wiki.

Quick SMS configuration

Default configuration has optimal parameters present to ensure best performance of track quality and data usage.
Quickly set up your device by sending this SMS command to it:
text

Note: Before SMS text, two space symbols should be inserted.

GPRS settings:

  • – APN
  • – APN username (if there are no APN username, empty field should be left)
  • – APN password (if there are no APN password, empty field should be left)

Server settings:

  •  – Domain
  •  – Port
  •  – Data sending protocol (0 – TCP, 1 – UDP)
    graphical user interface, text, application, chat or text
message
Default configuration settings

Movement and ignition detection:

Vehicle movement will be detected by accelerometer
icon

Ignition will be detected by vehicle power voltage between 13,2 – 30 V
icon

Device makes a record On Moving if one of these events happen:

300 seconds passes
a clock that is on a pole

Vehicle drives 100 meters
icon

Vehicle turns 10 degrees
icon

Speed difference between last coordinate and current position is greater than 10 km/h
icon

Device makes a record On Stop if:

1 hour passes while vehicle is stationary and ignition is off
a close up of a clock

Records sending to server:

If device has made a record it is sent to the server every 120 seconds
a clock that is on a pole

After successful SMS configuration, FMB130 device will synchronize time and update records to configured server. Time intervals and default I/O elements can be changed by using Teltonika Configurator or SMS parameters.

Mounting recommendations

  • Connecting wires
    ▬ Wires should be connected while the module is not plugged in.
    ▬ Wires should be fastened to stable wires or other nonmoving parts. Any heat emitting and/or moving objects should be kept away from the wires.
    ▬ There should be no exposed wires. If factory isolation was removed while connecting the wires, the isolation material should be applied.
    ▬ If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied and the wires should not be loose.
    ▬ Wires cannot be connected to the board computers or control units.

  • Connecting power source
    ▬ Be sure that after the car computer goes to sleep mode, power might be still available on the power wires.
    Depending on the car model, this may happen in 5 to 30 minutes period.
    ▬ When the module is connected, measure the voltage again to make sure it did not decrease.
    ▬ It is recommended to connect to the main power cable in the fuse box.
    ▬ 3 A, 125 V external fuse shall be used.

  • Connecting ignition wire
    ▬ Be sure to check if it is a real ignition wire i. e. power does not disappear after starting the engine.
    ▬ Check if this is not an ACC wire (when key is in the first position, most of the vehicle electronics are available).
    ▬ Check if power is still available when you turn off any of vehicles devices.
    ▬ Ignition is connected to the ignition relay output. As alternative, any other relay, which has power output when ignition is on, may be chosen.

  • Connecting ground wire
    ▬ Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
    ▬ If the wire is fixed with the bolt, the loop must be connected to the end of the wire.
    ▬ For better contact scrub paint from the spot where loop is going to be connected.

LED indications

Table 3 Navigation LED indications

BEHAVIOUR MEANING
Permanently switched on GNSS signal is not received
Blinking every second Normal mode, GNSS is working
Off GNSS is turned off because:

Device is not working or Device is in sleep mode
Blinking fast constantly| Device firmware is being flashed

Table 4 Status LED indications

BEHAVIOUR MEANING
Blinking every second Normal mode
Blinking every two seconds Sleep mode
Blinking fast for a short time Modem activity
Off Device is not working or Device is in boot mode

Basic characteristics

Table 5 Basic characteristics

MODULE

Name| Teltonika TM2500
Technology| GSM/GPRS/GNSS/BLUETOOTH
GNSS
GNSS| GPS, GLONASS, GALILEO, BEIDOU, SBAS, QZSS, DGPS, AGPS
Receiver| Tracking: 33
Tracking sensitivity| -165 dBM
Accuracy| < 3 m
Hot start| < 1 s
Warm start| < 25 s
Cold start| < 35 s
CELLULAR
Technology| GSM
2G bands| Quad-band 850 / 900 / 1800 / 1900

MHz

Data transfer| GPRS Multi-Slot Class 12 (up to 240

kbps), GPRS Mobile Station Class B

Data support| SMS (text/data)
POWER
Input voltage range| 10-30 V DC with overvoltage protection
Back-up battery| 170 mAh Li-Ion battery 3.7 V (0.63 Wh)
Power consumption| At 12V < 2.5 mA (Ultra Deep Sleep) At 12V < 5 mA (Deep Sleep)
At 12V < 5.5 mA (Online Deep Sleep) At 12V < 18,5 mA (GPS Sleep)
At 12V < 34 mA (nominal with no load)
BLUETOOTH
Specification| 4.0 + LE
Supported peripherals| Temperature and Humidity sensor, Headset, OBDII dongle, Inateck Barcode Scanner, Universal BLE sensors support
INTERFACE
Digital Inputs| 3
Negative Inputs 1| 1 (Digital Input 2)
Impulse Inputs| 2 (Digital Input 1, Digital Input 2)
Digital Outputs| 3
Analog Inputs| 2
CAN Adapter inputs| 1
1-Wire| 1
GNSS antenna| Internal High Gain
GSM antenna| Internal High Gain
USB| 2.0 Micro-USB
LED indication| 2 status LED lights
SIM| Micro-SIM + eSIM
Memory| 128MB internal flash memory
PHYSICAL SPECIFICATION
Dimensions| 65 x 56 x 20,6 mm (L x W x H)
Weight| 55 g
OPERATING ENVIRONMENT
Operating temperature (without battery)| -40 °C to +85 °C
Storage temperature (without battery)| -40 °C to +85 °C
Operating humidity| 5% to 95% non-condensing
Ingress Protection Rating| IP41
Battery charge temperature| 0 °C to +45 °C
Battery discharge temperature| -20 °C to +60 °C
Battery storage temperature| -20 °C to +45 °C for 1 month

-20 °C to +35 °C for 6 months

FEATURES
Sensors| Accelerometer

Scenarios

| Green Driving, Over Speeding detection, Jamming detection, GNSS Fuel Counter, DOUT Control Via Call, Excessive Idling detection, Immobilizer, iButton Read Notification, Unplug detection, Towing detection, Crash detection, Auto Geofence, Manual Geofence, Trip
Sleep modes| GPS Sleep, Online Deep Sleep, Deep Sleep, Ultra Deep Sleep
Configuration and firmware update| FOTA Web, FOTA, Teltonika Configurator (USB, Bluetooth), FMBT mobile application (Configuration)
SMS| Configuration, Events, DOUT control, Debug
GPRS commands| Configuration, DOUT control, Debug
Time Synchronization| GPS, NITZ, NTP
Fuel monitoring| LLS (Analog), LV-CAN200, ALL-CAN300, OBDII dongle, CAN-CONTROL, OBDII dongle
Ignition detection| Digital Input 1, Accelerometer, External Power Voltage, Engine RPM (CAN Adapters, OBDII dongle)

Electrical characteristics

Table 6 Electrical characteristics

CHARACTERISTIC DESCRIPTION VALUE
MIN TYP.

SUPPLY VOLTAGE
Supply Voltage (Recommended Operating Conditions)| +10| | +30| V
DIGITAL OUTPUT (OPEN DRAIN GRADE)
Drain current (Digital Output OFF)| | | 120| µA
Drain current (Digital Output ON, Recommended Operating Conditions)| | 0.1| 0.5| A
Static Drain-Source resistance (Digital Output ON)| | 400| 600| mΩ
DIGITAL INPUT
Input resistance (DIN1)| 47| | | kΩ
Input resistance (DIN2)| 38.45| | | kΩ
Input resistance (DIN3)| 150| | | kΩ
Input voltage (Recommended Operating Conditions)| 0| | Supply voltage| V
Input Voltage threshold (DIN1)| | 7.5| | V
Input Voltage threshold (DIN2)| | 2.5| | V
Input Voltage threshold (DIN3)| | 2.5| | V
DIGITAL INPUT
Input voltage (Recommended Operating Conditions), Range 1| 0| | +10| V
Input resistance, Range 1| | 38.45| | kΩ
Measurement error on 12V, Range 1| | 0.9| | %
Additional error on 12 V, Range 1| | 108| | mV
Measurement error on 30 V, Range 1| | 0.33| | %
Additional error on 30 V, Range 1| | 88| | mV
Input Voltage (Recommended Operating Conditions), Range 2| 0| | +30| V
Input resistance, Range 2| | 150| | kΩ
Measurement error on 12 V, Range 2| | 0.9| | %
Additional error on 12 V, Range 2| | 108| | mV
Measurement error on 30 V, Range 2| | 0.33| | %
Additional error on 30 V, Range 2| | 88| | mV
OUTPUT SUPPLY VOLTAGE 1-WIRE
Supply voltage| +4.5| | +4.7| V
Output inner resistance| | 7| | Ω
Output current (Uout > 3.0 V)| | 30| | mA
Short circuit current (Uout = 0)| | 75| | mA
NEGATIVE INPUT
Input resistance| 38.45| | | kΩ
Input voltage (Recommended Operating Conditions)| 0| | Supply voltage| V
Input voltage threshold| | 0.5| | V
Sink current| | | 180| nA

Safety information

This message contains information on how to operate FMB130 safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!

  • The device uses SELV limited power source. The nominal voltage is +12 V DC. The allowed voltage range is +10..+30 V DC.
  • To avoid mechanical damage, it is advised to transport the device in an impact-proof package. Before usage, the device should be placed so that its LED indicators are visible. They show the status of device operation.
  • When connecting the 2×6 connector wires to the vehicle, the appropriate jumpers of the vehicle power supply should be disconnected.
  • Before unmounting the device from the vehicle, the 2×6 connector must be disconnected. The device is designed to be mounted in a zone of limited access, which is inaccessible to the operator. All related devices must meet the requirements of EN 60950-1 standard.
    The device FMB130 is not designed as a navigational device for boats.

Do not disassemble the device. If the device is damaged, the power supply cables are not isolated or the isolation is damaged, DO NOT touch the device before unplugging the power supply.

__ All wireless data transferring devices produce interference that may affect other devices which are placed nearby.

iconThe device must be connected only by qualified personnel.

iconThe device must be firmly fastened in a predefined location.

iconThe programming must be performed using a PC with autonomic power supply.

Installation and/or handling during a lightning storm is prohibited.

iconThe device is susceptible to water and humidity.

__ CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.

iconBattery should not be disposed of with general household waste. Bring damaged or worn- out batteries to your local recycling center or dispose them to battery recycle bin found in stores.

Certification and Approvals

This sign on the package means that it is necessary to read the User‘s Manual before your start using the device. Full User‘s Manual version can be found in our Wiki.

iconThis sign on the package means that all used electronic and electric equipment should not be mixed with general household waste.

Hereby, Teltonika declare under our sole responsibility that the above described product is in conformity with the relevant Community harmonization: European Directive 2014/53/EU (RED).

logo, company nameFor more information, see the ANATEL websitewww.anatel.gov.br
This equipment is not entitled to protection against harmful interference and must not cause interference in duly authorized systems

Warranty

TELTONIKA guarantees its products to be free of any manufacturing defects for a period of 24 months. With additional agreement we can agree on a different warranty period, for more detailed information please contact our sales manager.

Contact us teltonika.lt/company/contacts

All batteries carry a reduced 6 month warranty period.

If a product should fail within this specific warranty time, the product can be:

  • Repaired
  • Replaced with a new product
  • Replaced with an equivalent repaired product fulfilling the same functionality
  • TELTONIKA can also repair products that are out of warranty at an agreed cost.

Warranty Disclaimer

TELTONIKA PRODUCTS ARE INTENDED TO BE USED BY PERSONS WITH TRAINING AND EXPERIENCE. ANY OTHER USE RENDERS THE LIMITED WARRANTIES EXPRESSED HEREIN AND ALL IMPLIED WARRANTIES NULL AND VOID AND SAME ARE HEREBY EXCLUDED.
ALSO EXCLUDED FROM THIS LIMITED WARRANTY ARE ANY AND ALL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO, LOSS OF USE OR REVENUE, LOSS OF TIME, INCONVENIENCE OR ANY OTHER ECONOMIC LOSS.

More information can be found at teltonika.lt/warranty-repair