ELRO Smoke Alarm Instruction Manual
- June 7, 2024
- ELRO
Table of Contents
ELRO Smoke Alarm Instruction Manual
Firstly
Follow instructions to ensure proper installation. Intended use: Fire detection and fire warning for household or similar residential applications. Local regulations shall be consulted.
INTENDED USE: FIRE SAFETY
ESSENTIAL CHARACTERISTICS: PASSED
Nominal activation conditions/ Sensitivity, Response delay (response time) and Performance under fire condition – Operational reliability – Tolerance to supply voltage – Durability of operational reliability and response delay, temperature resistance, vibration resistance, humidity resistance, corrosion resistance, electrical stability
Manufacturer :
Siterwell Electronics CO., Limited
No.666 Qingfeng Road, Jiangbei District,
Ningbo, Zhejiang Province, China 315034
Importer
ELRO Europe | www.elro.eu
Postbus 9607 – Box E800
1006 GC Amsterdam The Netherlands
Content
Activate before use!
Press and hold test button until LED lights up, then release immediately.
Testing
Mounting plate
Ceiling mounting
Rooms
Test & clean
Alarm silence
Low battery
Overview LED & acoustic signalling
Symbols:
Recycling and disposal: The WEEE symbol means that this product and batteries
must be disposed separately from other household waste. When it reaches its
end of life, take it to a designated waste collection point in your area to
guarantee a safe disposal or recycling. Protect the environment, human health
and natural resources!
Read the manual before use and store it in a safe place for future use and
maintenance.
Download Declaration of Performance (DoP) at
www.elro.eu.
Warnings:
- To prevent injury, this apparatus must be securely attached to the ceiling in accordance with the installation instructions.
- Batteries shall not be exposed to excessive heat such as sunshine and fire.
- Battery lifetime shortens without monthly test.
- Keep away from air conditioning/ventilation.
- Do not paint or cover device.
- Consult local regulations.
Troubleshooting:
False alarm is often caused by dust or steam. In case of doubt: Leave the building and take action! Additional mounting instructions: Corridor max width 3m: Max 15m between 2 alarms. Max. 7,5m to front side and alarms at edges/crossings of corridors. Galleries: Length and width >2m and >16m², additional alarms below gallery. Partial roof slopes: Flat ceiling ≤1m wide, consider as roof slope. Flat ceiling >1m wide, consider as flat ceiling.