COLDBUSTER CB Dual Thermostat User Manual

June 3, 2024
COLDBUSTER

Dual Thermostat
User Manual

COLDBUSTER CB Dual Thermostat

Instruction

The CB Manual thermostat control a floor heating system based on a built-in weekly program. You can set individual temperatures for 4 events or 2 events on different days of the week. The default weekly program parameters can satisfy most installations. If your living habits are different, you can update the weekly program parameters in the thermostat or APP. Lowering the temperature when the home is unoccupied will reduce your energy costs without reducing comfort. Furthermore, the thermostat features
an adaptive function that automatically changes heating period start times to ensure that the required temperature is reached at the required time. After some days the adaptive function has learned when the heating must be switched on.

Technical Specification

Supply voltage: 85-265 VAC 50/60 Hz
Load: Max.16 A (resistive load)
Standby Power Loss:   <1W
Cable Diameter: ≤2.5mm²
  1. Loosen the bottom screw with a Phillips screwdriver. Then open the thermostat from the right corner as shown.
    Note: Screw the nut out of the groove. No need to unscrew it

  2. Wire as shown:
    L/N lead:| Connect the power cord using the terminal block. Use a terminal block to
    connect the load line.
    ---|---
    L1/N1 lead:| Use a terminal block to connect the load line.

COM/S1 terminal: Connect the floor sensor.
Note: Disconnect the main power supply before wiring

  1. Install the back cover into the terminal box and secure it with the set screw.

  2. Install the back cover into the terminal box and secure it with the set screw.

1. On/Off Button
2. Mode
3. Temperature
4. Sensor selection| 5. setpoint
6. Event
7. Day and time
8. Touch key
---|---

Function and operation

On/Off
Press button to turn on or turn off
Temporary Override Temperature
Override temperature is a temporary temperature setting in auto mode and it has no effect on schedule 4-event program.
To do so:
With Active Display press ▲ or ▼ buttons to set temperature.
Press the OK button to confirm and return back to active display interface.
Mode selection
Three Mode is available.
Auto mode: The thermostat automatically runs according to the weekly-program parameters. Manual Mode: Thermostat runs according to manually select temperature.
Anti-frozen mode: The thermostat runs at a lower set temperature. The temperature range can be set from 5°C to 15°C in this mode. This mode is used the home is unoccupied and keep the home at a lower temperature
To do so:
With Active Display (backlight on) press OK to activate the menu. The MODE option flashes.
Press OK button.
Press the ▲ or ▼ button to get mode you need.
Press OK button to confirm.
If you select manual mode or Anti-frozen mode, you also need to press ▲ or ▼ to set the temperature.
Press OK button to get back to Active Display.
Key lock
I want to lock the thermostat menus to prevent the settings from being changed.
Note: For emergency, can run
To do so:

  1. With Active Display (backlight on) press until lock symbol comes.
  2. With Active display, press OK button MODE is flashes.

Press ▲or▼ button until the Key lock option flashes.
Press OK button to set.
Press OK button to confirm.
Press OK button to get back to Active display.
To unlock the Key lock:
With Active display, press and hold the button simultaneously for three seconds
Weekly program parameter setting
In the auto mode, the thermostat runs automatically according to the setting parameters of the weekly program. The weekly program parameters contain two major parameters: Schedule and Event.
Schedule: Two schedule for a week.
5+1+1: The Event parameter is the same from Monday to Friday, with separate Event parameters on Saturday and Sunday.
7: Separate Event parameters every day
Schedule setting:
With Active display, press OK button. The MODE option flashes.
Press▲or▼button to get Schedule.
Press OK button to enter.
Press▲or▼button to set.
Press OK button to confirm.
Press OK button to come back to Active display.
Event: Home

  • when I wake up in the morning
  • when I am away at work
  • when I come home
  • and at night

Event: Office

  • When I am at office
  • When I get off work

Temperature in each event can be set
To do so:
With Active display, press OK button Mode option flashes.
Press▲or▼ button to get Event.
Press OK button to get week.
Press▲or▼ button to get the day.
Press OK button to enter event.
Press▲or▼ button to set the parameters in that event.
Press OK button to set the temperature for this phase.
Press▲or▼ button to set the temperature.
Press OK button to set the hour that the temperature start.
Press▲or▼ button to set hour.
Press OK button to set the Minutes that the temperature start.
Press▲or▼ button to set minutes.
Press OK button to come back to this phase.
Note: Press several times to get back to active display.
Event: Factory Settings for Event

Home

Week| Wake| Leave| Return| Sleep
| Start time| Tempera- ture
ture| Start time| Tempera- ture| Start time| Tempera- ture| Start time| Tempera- ture
Mon–Fri| 6:00| 25.5’C| 8:00| 20.5°C| 17:00| 25.5°C| 22:00| 20.5°C
Sat–Sun| 8:00| 25.5’C| 8:30| 25.5°C| 17:30| 25.5°C| 23:00| 20.5°C
Office
Week| At work| Get off work| |
| Start time| Tempera- ture
ture| Start time| Tempera-| | | |
Mon–Fri| 7:00| 25.5°C| 18:00| 20.5°C| | | |
Sat–Sun| 7:00| 20.5°C| 18:00| 20.5°C| | | |

Sensor Selection

This thermostat has floor sensor and built-in sensors to detect room temperature. Therefore, three sensor applications are available:
Room: Controls room temperature based solely on built-in sensors.
Floor: Controls the floor temperature based solely on the floor sensor.
Room.Limit: Controls the room temperature based on the built-in sensor while monitoring the floor temperature not exceed the upper limit. This application can be used in places such as wood floors where floor temperature is critical.
Sensor Selection setting
Enter settings. Press▲or▼button to get sensor selection.
Press OK to enter.
Press ▲or▼button to get sensor you need.
Press OK button to confirm.
Press OK button to come back to active display.

Calibration

This thermostat has built-in probe and floor sensor calibration function. In the case of demand for higher precision.
Calibration setting:
Enter settings. Press▲or▼button to get Calibration.
Press OK button to get room or floor.
Press▲or▼button to get built-in probe or floor sensor.
Press OK button to enter calibration.
Tap ▲ or ▼ to adjust the real-time temperature to match the displayed temperature value of the calibration instrument.
Press OK button to come back to Active display.

Location

This thermostat is suitable for use in both homes and offices. For the office, a set of weekly program parameters is built in. See the Weekly Program Parameters section for details.
Location setting:
Enter settings. Press▲or▼button to get Location.
Press OK button to get office or home.
Press▲or▼button to get office or home.
Press OK button to confirm.
Press OK button to come back to Active display.

Adaptive

The thermostat features an adaptive function that automatically changes heating period start times so as to ensure that the required temperature is reached at the required time.
Adaptive setting:
Enter settings. Press▲or▼button to adaptive.
Press OK button to get.
Press▲or▼ to get Yes or No.
Press OK button to confirm.
Press OK button to come back to active display

Readout

This thermostat can read the amount of time (in percent) that the heating has been turned on within a certain period.
Readout setting:
Enter settings. Press▲or▼button to Readout.
Press OK button to get.
Press▲or▼button to get 1Day, 30Days and 365Days.
Press OK button to come back to setting interface.

Factory Reset

Factory Reset setting:
Enter settings. Press▲or▼button to Factory Reset.
Press OK button to get.
Press▲or▼button to get Yes or NO.
Press OK button to confirm.
Press OK button to come back to Active display interface.

Setting parameters

No. Name Default parameter Setting range
1 Time / /
2 °F/°C °F °F

°C
3| Sensor Type| 00 3950| 00 3950
01 3600
02 3700
4| Sensor Selection| Floor| Room
Floor
Room.Limit
5| Calibration| 0°C| -5°C — 5°C
6| Location| Home| Home
Office
7| Adaptive| No| Yes
No
8| Readout| /| /
9| Factory Reset| N
0| No
Yes

Troubleshooting

E1: Built-in probe failure, please contact your dealer or professional technician.
E2: External probe failure, please contact your dealer or professional technician.
Dimension (mm)

COLDBUSTER CB Dual Thermostat - 6 Coldbuster Floor Heating
8/81 Frenchs Forest Road E
Frenchs Forest NSW 2086
Phone: +61 2 9982 5374 / Toll Free: 1800 85 75 65
Email:sales@coldbuster.com.au
Website:www.Coldbuster.com.a

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals