Technical Specification:

  • Supply voltage: 85-265 VAC
  • Frequency: 50/60 Hz
  • Maximum Load: 16 A (resistive load)

Standby Power Loss:

The standby power loss of the CB BASIC is not specified in the provided text.

To use the CB BASIC Coldbuster Floor Heating:

  1. Ensure the supply voltage is within the range of 85-265 VAC.
  2. Connect the CB BASIC to the power source using appropriate wiring and connectors.
  3. Make sure the load does not exceed the maximum load capacity of 16 A for resistive load.
  4. Follow the installation instructions provided in the user manual for proper installation of the floor heating system.
  5. Refer to the user manual for detailed instructions on operating the CB BASIC Coldbuster Floor Heating.

If you have any questions or need further assistance, contact Coldbuster using the provided contact information.

Instruction

The CB Basic thermostat controls a floor heating system based on a built-in weekly program. You can set individual temperatures for 4 events or 2 events on different days of the week. The default weekly program parameters can satisfy most installations. If your living habits are different, you can update the weekly program parameters in the thermostat or APP. Lowering the temperature when the home is
unoccupied will reduce your energy costs without reducing comfort. Furthermore, the thermostat features an adaptive function that automatically changes heating period start times to ensure that the required temperature is reached at the required time. After some days the adaptive function has learned when the heating must be switched on.

Technical Specification

  • Supply voltage: 85-265 VAC 50/60 Hz
  • Standby Power Loss: <1W Load: Max.16 A (resistive load)
  • Cable Diameter: ≤2.5mm²

INSTALLATION STEPS

  1. Loosen the bottom screw with a Phillips screwdriver.Then open the thermostat from the right corner asshown.Note: Screw the nut out of the groove. No need tounscrew it.

  2. Wire as shown:

  3. L/N lead:
    Connect the power cord using the terminalblock.Use a terminal block to connect the loadline.

  4. L1/N1 lead:
    Use a terminal block to connect the loadline.
    COM/S1 terminal: Connect the floor sensor.
    Note : Disconnect the main power supply before wiring

  5. Install the back cover into the terminal box and secureit with the set screw.

  6. Install the back cover into the terminal box andsecure it with the set screw.

Function and Operation

  • On/Off Press button to turn on or turn off.
  • Temporary Override Temperature Override temperature is a temporary temperature setting in auto mode and has no effect on schedule 4-event program

To Do So:
With Active Display press ▲ or ▼ to set temperature. Press OK to confirm and return to Active Display.

Mode Selection
Three Modes are available.
Auto Mode: The thermostat automatically runs according to the weekly-program parameters.
Manual Mode: The thermostat runs according to manually select temperature.
Anti-frozen Mode: The thermostat runs at a lower set temperature. The temperature range can be set from 5°C to 15°C in this mode. This mode is intended to be used when the home is unoccupied and keeps the home at a lower temperature.

To Do So:

  • With Active Display (backlight on) press OK to activate the menu. MODE flashes.
  • Press OK to confirm.
  • Press ▲ or ▼ to choose mode you need.
  • Press OK to confirm.
  • If you select Manual mode or Anti-frozen mode, you also need to press ▲ or ▼ to set the temperature. Press OK to confirm and return to Active Display.

Key Lock
To lock the thermostat menus to prevent the settings from being changed. Note: For emergency, can run.

To Do So:

1. With Active Display (backlight on) press |◄ until lock symbol appears.
2. With Active Display, press OK button until MODE flashes.
Press ▲or▼ until the Key lock option flashes.
Press OK to set.
Press OK to confirm.
Press OK to get back to return to Active Display.

To unlock the Key lock:
With Active Display, press and hold |◄ simultaneously for three seconds.

Weekly Program Parameter Setting
In the auto mode, the thermostat runs automatically according to the setting parameters of the weekly program.
The weekly program parameters contain two major parameters: Schedule and Event.

Schedule: Two schedules for a week.
5+1+1: Event parameter is the same Monday to Friday, with separate Event parameters on Saturday and Sunday. 7: Separate Event parameters every day.

Schedule Setting:

  • With Active Display, press OK until MODE flashes. Press ▲or▼ to choose Schedule.
  • Press OK to enter.
  • Press ▲or▼ to set.
  • Press OK to confirm.
  • Press OK to return to Active Display.

Event: Home

  • when I wake up in the morning
  • when I am away at work
  • when I come home
  • and at night

Event: Work

  • When I am at work
  • When I get off work
  • Temperature in each event can be set.

To Do So:

  • With Active Display, press OK until MODE flashes. Press ▲or▼ to choose Event.
  • Press OK to choose week.
  • Press ▲or▼ to choose the day.
  • Press OK to enter event.
  • Press ▲or▼ to set the parameters in that event.
  • Press OK to set the temperature for this phase.
  • Press ▲or▼ button to set the temperature.
  • Press OK to set the hour that the temperature starts. Press ▲or▼ to set hour.
  • Press OK to set the minutes that the temperature starts. Press ▲or▼ to set minutes.
  • Press OK to return to this phase.

Note: Press |◄ several times to get back to active display.
Event : Factory Settings for Event

Settings
This thermostat also can be used to other application with different setting. It should be set by professional technicians to avoid damage caused by abnormal settings.

To Do So:

With Active Display, press OK until MODE flashes. Press ▲or▼ to choose settings.
Press OK to confirm.

Setting Parameter

Time
Set date and week

Time Setting:

  • Choose setting. Press ▲or▼button to set time. Press OK button to confirm.
  • Press ▲or▼button to choose hour you need. Press OK button to set minutes.
  • Press ▲or▼button to choose minutes you need. Press OK button to set week.
  • Press ▲or▼button to choose the day you need. Press OK button to enter the hour setting of the day

Note : Press |◄ several times to get back to active display.

Temp Unit

Change the temperature unit (°C/°F) used in the display.

  • Temp Unit Setting:
  • Choose settings. Press ▲or▼ to choose °F/°C. Press OK to enter.
  • Press ▲ or▼ to choose the unit.
  • Press OK to confirm.
  • Press OK to return to Active Display.

Sensor Type
This thermostat can be connected not only to the provided floor sensor but also to two other commonly used floor sensors. When replacing an old thermostat, there is no need to replace the floor sensor.

Sensor Type Setting:

  • Choose settings. Press ▲or▼ to choose Sensor type. Press OK to enter.
  • Press ▲ or▼ to select Sensor type.
  • Press OK to confirm.
  • Press OK to return to Active Display.

Sensor Selection

This thermostat has floor sensor and built-in air sensors to detect room temperature. Therefore, three sensor applications are available:
Room : Controls the room temperature based solely on built-in sensors.
Floor : Controls the floor temperature based solely on the floor sensor.
Room.Limit: Controls the room temperature based on built-in sensors while monitoring the floor temperature to ensure it does not exceed an upper limit. This application can be used in places such as timber floors where maximum floor temperature is critical.

Sensor Selection Setting:

  • Enter settings. Press ▲ or▼ to choose sensor selection. Press OK to enter.
  • Press ▲ or ▼ to choose required sensor.
  • Press OK to confirm.
  • Press OK to return to Active Display.

Calibration

This thermostat has built-in probe and floor sensor calibration function in the case of demand for higher precision.

Calibration Setting:

  • Enter settings. Press ▲ or ▼ to choose Calibration.
  • Press OK to choose room or floor.
  • Press ▲ or ▼ to choose built-in probe or floor sensor.
  • Press OK to enter calibration.
  • Press ▲ or ▼ to adjust the real-time temperature to match the displayed temperature value of the calibration instrument.
  • Press OK to return to Active Display.

Location

This thermostat is suitable for use in both homes and workplaces. For the workplace, a set of weekly program parameters is built in. See the Weekly Program Parameters section for details.

  • Location Setting:
  • Enter settings. Press ▲or▼button to choose Location. Press OK button to choose office or home.
  • Press ▲or▼button to choose office or home.
  • Press OK button to confirm.
  • Press OK to return to Active Display.

Adaptive

This thermostat features an adaptive function that automatically changes heating period start times to ensure that the required temperature is reached at the required time.

Adaptive Setting:

  • Enter settings. Press ▲ or ▼ to adaptive. Press OK.
  • Press ▲ or ▼ to choose Yes or No. Press OK to confirm.
  • Press OK to return to Active Display.

Readout

This thermostat can read the percentage of time that the heating has been turned on within a certain period.

  • Readout Setting:
  • Enter settings. Press ▲ or ▼ to Readout.
  • Press OK.
  • Press ▲ or ▼ to choose 1Day, 30Days or 365Days. Press OK to return to Active Display.

Factory Reset

  • Factory Reset Setting:
  • Enter settings. Press ▲ or ▼ to Factory Reset. Press OK.
  • Press ▲ or ▼ to choose Yes or NO.
  • Press OK to confirm.
  • Press OK to return to Active Display.

Setting parameters

Troubleshooting

E1: Built-in probe failure, please contact your dealer or professional technician. E2: External probe failure, please contact your dealer or professional technician.

Dimensions

(mm)

Coldbuster Floor Heating Unit 10, 14 Rodborough Rd Frenchs Forest NSW 2086
Phone : +61 2 9982 5374
Toll Free : 1800 85 75 65
Email : sales@coldbuster.com.au
Website : www.coldbuster.com.au

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals