ULINE Shark Navigator Lift-Away Vacuum User Guide

June 7, 2024
ULINE

ULINE-Logo.png H-8831
SHARK®NAVIGATOR™
LIFT-AWAY®VACUUM

1-800-295-5510
uline.com

ULINE Shark Navigator Lift-Away

SAFETY

** CAUTION!** To reduce the risk of electric shock, the appliance has a polarized plug (one blade is wider than the other). Plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not alter the plug in any way.

**NOTE:** Read the following warnings to reduce the risk of fire, electric shock, injury, or property damage.

GENERAL WARNINGS

  • This vacuum features a motorized nozzle, wand, hose, and/or vacuum pod. This device contains electrical connections, electrical wiring, and moving parts that potentially present a risk to the user.
  •  Use only identical replacement parts.
  • Carefully observe and follow the instructions provided below to avoid improper use of the appliance. Do not use the vacuum for any purpose other than those described in these instructions.
  • Before use, carefully inspect all parts for any damage. Do not use if any parts are damaged.
  •  The use of an extension cord is not recommended.
  •  Vacuum contains no serviceable parts.

USE WARNINGS

  •  Do not allow the vacuum to be used by children. Close supervision is necessary when used near children.  This is not a toy.

  • Always turn off the vacuum before connecting or disconnecting any motorized nozzles or other accessories.

  • Do not handle plug or vacuum with wet hands.

  • Do not use without filters in place.

  •  Only use Shark®brand filters and accessories. Failure to do so will void the warranty.

  • Do not damage the power cord:
    a) Do not pull or carry vacuum by the cord or use the cord as a handle.
    b) Do not unplug by pulling on the cord. Grasp the plug, not the cord.
    c) Do not run the vacuum over the power cord, close a door on the cord, pull the cord around sharp corners, or leave the cord near heated surfaces.

  • Do not put any objects into nozzle or accessory openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce airflow.

  • Do not use if nozzle or accessory airflow is restricted. If the air paths or the motorized floor nozzle become blocked, turn the vacuum off and unplug from the electrical outlet. Remove all obstructions before plugging in, and turn on the unit again.

  • Keep nozzle and all vacuum openings away from hair, face, fingers, uncovered feet or loose clothing

  • Do not use if a vacuum is not working as it should, or has been dropped, damaged, left outdoors, or dropped into water.

  • Use extra care when cleaning on stairs.

  • Do not leave the vacuum unattended while plugged in.

  • When powered on, keep the vacuum moving over the carpet surface at all times to avoid damaging the carpet fibers.

  • Do not place the vacuum on unstable surfaces such as chairs or tables.

  • Do not use to vacuum:
    a) Liquids
    b) Large objects
    c) Hard or sharp objects (glass, nails, screws or coins)
    d) Large quantities of dust (drywall dust, fireplace ash or embers). Do not use as an attachment to power tools for dust collection.
    e) Smoking or burning objects (hot coals, cigarette butts or matches)
    f) Flammable or combustible materials (lighter fluid, gasoline or kerosene)
    g) Toxic materials (chlorine bleach, ammonia or drain cleaner)

  •  Do not use in the following areas:
    a) Poorly lit areas
    b) Wet or damp surfaces
    c) Outdoor areas
    d) Enclosed spaces that may contain explosive or toxic fumes or vapors (lighter fluid, gasoline, kerosene,  paint, paint thinners, mothproofing substances, or flammable dust)

  • Turn off all controls before plugging in or unplugging the vacuum.

  • Unplug from the electrical outlet when not in use and before any maintenance or cleaning.

  • Hand washes with water only. Washing with cleaning chemicals could damage the unit.

  • During cleaning or routine maintenance,do not cut anything other than hair, fibers or string wrapped around the brushroll.

  •  Allow all filters to air-dry completely before replacing in the vacuum to prevent liquid from being drawn into electric parts.

  • Ensure the dust cup and all filters are in place after routine maintenance.

  •  If provided, secure the power cord around the two cord hooks during storage.

ASSEMBLY

  1.  Place pod onto floor nozzle post and slide it down until it clicks into place.
  2. Insert extension wand into pod until it clicks into place.
  3. Slide accessory holder onto wand with post facing away from cord hook4. Insert handle assembly into wand until it clicks into place.
  4. Insert the flexible hose into the connector on the back of the pod.

NOTE: For proper operation, ensure all parts are firmly clicked into place.

ULINE Shark Navigator Lift-

OPERATION

SETTINGS

  1.  Press the Power/Surface switch at the top of the pod. (See Figure 2)

  2. Select surface setting:
    • 0 Power Off
    • I Bare Floor (for bare floors and small area rugs)
    • II Carpet

  3.  Suction Control offers variable suction based on the user’s needs. Rotate counter-clockwise to reduce suction and increase maneuverability on carpets. Rotate clockwise to increase suction on bare floors. (See Figure 3)

BRUSH ROLL INDICATOR LIGHT

The color of light indicates the status of the brush roll. (See Figure 4)

  • Solid Green: Brush roll is spinning and working as it should.
  • Solid Red: There is a jam in the brush roll area. Turn the vacuum off and remove blockages in the nozzle.
  • No Light: The vacuum is off.

NOTE: For deep carpet cleaning per ASTM F608 (embedded dirt in carpets), use setting II, Carpet.

CLEANING MODES
UPRIGHT
To engage brush roll, turn on the power, then step on the floor nozzle and tilt the handle back. (See Figure 5)

ULINE Shark Navigator Lift-Away fg5

LIFT-AWAY
Press the red release button on the side of the pod. Gently hold the nozzle to the floor with your foot and pull the pod up. (See Figure 6)

ULINE Shark Navigator Lift-Away fg6 ABOVE-FLOOR EXTENDED REACH
Follow instructions for detaching the pod above. Press the wand release button to remove the wand from the pod. Attach an accessory to the end of the wand.(See Figure 7)

ULINE Shark Navigator Lift-Away fg7
ABOVE-FLOOR
Follow instructions for detaching the pod and wand. Press the handle release button to detach the handle from the wand. Attach an accessory to the end of the handle. (See Figure 8)
NOTE : All accessories are compatible with both the wand and the handle.

ULINE Shark Navigator Lift-Away fg8
EMPTYING THE DUST CUP

****IMPORTANT! Unplug the power cord before performing any maintenance.

  1. Undo the latches on the sides of the dust cup by lifting them up and out. Tilt the dust-up and lift it off the vacuum pod. (See Figure 9)ULINE Shark Navigator Lift-Away fg9
  2. To empty the debris into the trash, press the lower release button, and the bottom of the dust cup will drop open. (See Figure  10)ULINE Shark Navigator Lift-Away fg10
  3. To remove collected debris from the lint screen, press the top release button and lift the handle to open. Gently rush lint screen to clean. (See Figure 11)ULINE Shark Navigator Lift-Away fg11
  4. To reinstall, set the bottom of the dust cup on the pod and tilt it until the dust cup clicks into place. (See Figure 12)ULINE Shark Navigator Lift-Away fg12

MAINTENANCE

CLEANING FILTERS
Regularly clean and replace filters to keep vacuum suction power optimal. To clean filters, rinse with cold water only to prevent damage from cleaning chemicals. Allow all filters to air-dry for at least 24 hours before reinstalling them to prevent liquid from being drawn into electric parts.

****IMPORTANT! Do not use soap when cleaning the filters. Pre-Motor (foam and felt): (See Figure 13)

  •  With the dust cup removed, remove the foam and felt filters.
  • Clean pre-motor filters every three months. ULINE Shark Navigator Lift-Away fg13

Post-Motor (HEPA): (See Figure 14)

  • To access the HEPA filter, press the tab, tilt the filter cover, and lift it from the vacuum. Remove the HEPA  filter.
  •  Clean HEPA filter every year.ULINE Shark Navigator Lift-Away fg14

REPLACING FILTERS
Follow the instructions for removing filters. The pre-motor filter should be replaced every two and a half years.
The HEPA filter should be replaced every three years.

  • XHF350 = Replacement pre-motor foam and felt filter kit.
  • XHF350 = Replacement HEPA filter.

CLEANING THE BRUSH ROLL

  1. Detach pod from the floor nozzle.
  2. Remove any blockages or buildup from the airways in the nozzle. With scissors, carefully cut away any fibers, hair or string wrapped around the brush roll. Avoid damaging or cutting the bristles.(See Figure 15)ULINE Shark Navigator Lift-Away fg15

CHECKING FOR BLOCKAGES

  1. Detach the handle from the wand by pressing the handle release button. Remove flexible hose from the vacuum pod by pressing the tabs on the horse collar. Inspect the hose for clogs. (See Figure 16) ULINE Shark Navigator Lift-Away fg16
  2. Detach the pod, wand, hose, and dust cup. Check all openings and remove blockages. (See Figure 17) ULINE Shark Navigator Lift-Away fg17
  3. With the pod detached, remove the lower nozzle hose and check for clogs. (See Figure 18)ULINE Shark Navigator Lift-Away fg18
  4. Open the airway on the bottom of the floor nozzle by squeezing the tabs on the sides and lifting up. Check for clogs and clear away any obstructions. (See Figure 19) ULINE Shark Navigator Lift-Away fg18

TROUBLESHOOTING

OPERATING ISSUE RECOMMENDATIONS
Vacuum is not picking up dirt.

Check filters to see if they need cleaning. Follow instructions for rinsing and drying the filters before inserting them back into the vacuum.
See Cleaning FIlters and Replacing Filters on page 5. Dust cup may be full; empty dust cup.
Check hose, hose connections, nozzle, and accessories for blockages; clear blockages if required.
If dust cup is empty and attachment inlets are clear, check for other blockages. See Checking for Blockages on page 5.

Vacuum lifts area rugs.|

Suction is powerful. Take care when vacuuming area rugs or rugs with delicately sewn edges. Rotate suction control collar counterclockwise to decrease suction power.

Airflow is restricted. There is no suction or light suction.|

Check filters to see if they need cleaning. Follow instructions for rinsing and drying the filters before inserting them back into the vacuum.
See Cleaning FIlters and Replacing Filters on page 5. Dust cup may be full; empty dust cup.
Check hose, hose connections, nozzle, and accessories for blockages; clear blockages if required.
Rotate suction control collar clockwise to increase suction power.
If the dust cup is empty and attachment inlets are clear, check for other blockages. See Checking for Blockages on page 5.

Motorized brush roll is jammed or has shut off.|

Immediately turn off and unplug the vacuum, disconnect the nozzle and remove blockage before reconnecting and turning the vacuum back on. See Checking for Blockages on page 5.

Vacuum turns off on its own, or the indicator light flashes red.|

This vacuum is equipped with a motor-protective thermostat.
If vacuum overheats, the thermostat will automatically turn the suction motor off. Perform the following steps to restart the thermostat:

  1. 1. Turn the vacuum off and unplug it.
  2. 2. Empty dust cup and clean filters.
  3. 3.Check for blockages in hose, accessories and inlet openings.
  4. 4.Allow unit to cool for a minimum of 45 minutes.
  5. Plugin a vacuum and restart the unit with the Power/Surface switch.

CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA

ULINE-Logo.png

1-800-295-5510
uline.co

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals