Deluxe Submersible Pump User Guide

June 7, 2024
Deluxe

USER GUIDE

SIMPLE DELUXE STRIVES FOR 100% SATISFACTION.
Shipping damage? Questions? Contact us now and we will make it right!
TEL: +1877-718-4718
(M-E, 9am-5pm PST).
EMAIL: es@sipledelse.com
(replies within 1 business day).

SUBMERSIBLE PUMP
FOR MODEL 400 GPH (LGPUMP400G)

Simplified Instruction

Component List
Deluxe Submersible Pump Component List

Operation Instruction

SUBMERSIBLE APPLICATION

NOTE : Ensure the pump body is fully submerged in water never allow the water level to drop below pump intake.
Avoid running the pump dry!Deluxe Submersible Pump
Operation

INLINE APPLICATION

Deluxe Submersible Pump Operation INLINE
APPLICATIONDeluxe Submersible Pump
Operation INLINE

Maintenance & Cleaning

The Simple Deluxe submersible pumps do not require lubrication or special maintenance. The following maintenance and cleaning will improve the pump’s performance and life.
CLEANING: When the flow is visibly reduced you may want to clean the pump. Unplug the pump’s power cord first, then remove the pump from the water (Do NOT use the cord to lift the pump). Remove the back cover and the impeller. Use a small brush and tap water to remove any debris and build-up.
WARNING: Always disconnect from the electrical outlet before handling the pump.

CLEANING INSTRUCTION
STEP1:
Unplug the pump’s power cord. Deluxe Submersible Pump OperationSTEP1Deluxe
Submersible Pump OperationSTEP1STEP2:
Remove the pump from the water (Do NOT use the cord to lift the pump).

Deluxe Submersible Pump Operation STEP2STEP3:
Disassemble the pump as shown. Deluxe Submersible Pump Operation
STEP3STEP4:
Clean front cover, pre-filter, and impeller in clean water. Do not use detergents. Deluxe Submersible Pump OperationSTEP4

Safety Information

CAUTION
Electrical Warning: Risk of electric shock
1)This Simple Deluxe pump has not been evaluated for use in swimming pools or marine areas.

To reduce the risk of electric shock

  1. install only on a circuit protected by a ground-fault circuit interrupter (GFCI).
  2. See the User Guide section for proper installation

Warning:

  1. Keep children away from this appliance and do not let them play with the product

  2. DO NOT operate the unit if people are in the water.

  3. A high-voltage connector is in the unit. Be sure to turn off the main power supply prior to cleaning
    or performing any maintenance on the unit.

  4. Never cut the power plug and replace it yourself. This may lead to serious injury or death.

  5. Never open the pump housing or its components unless specified in this User Guide.

  6. Unplug the unit from the power source immediately if it shows any sign of abnormal water leakage.

  7.  This appliance should not be used if the plug or receptacle is wet.

  8. Do not operate if the power supply cord, plug or any other parts are damaged.

  9. Close supervision is necessary when used by or near children. This appliance is not a toy. Keep away from children.

  10. To avoid injury, do not contact moving parts

  11. Never yank on the cord to pull the plug from the outlet.

  12. Do not use this pump for other than intended use. The use of certain attachments not recommended or sold by Simple Deluxe may cause unsafe conditions and void product warranty.

  13. Make sure the pump is mounted securely to the tank, reservoir or pond.
    THIS APPLIANCE HAS LIMITED USER-SERVICEABLE PARTS The following restrictions apply to  this unit:
    •NEVER use this unit to pump fluids other than water
    • NEVER run this unit without water.
    • DO NOT use for commercial or industrial purposes
    • DO NOT use in conjunction with chemicals, foodstuffs, easily flammable or explosive substances.

USAGE CAUTIONS;
A. Before operating pump:

  1. Check that the power voltage and frequency conform to the power ratings on the nameplate.
  2.  Don’t lift, lower or carry the pump by the power cable.
  3. Always unplug the pump when not in use. Do not place hands in water where the pump is installed or before performing any maintenance and cleaning.
  4. Do not add any lubricants to the pump.
  5. Do not operate the Simple Deluxe pump without water as this will cause severe damage.
  6. This Simple Deluxe pump is not self-priming. Make sure the water lines and pump(s) are filled with water prior to turning on.
  7. Do not install or store the Simple Deluxe pump where it will be exposed to weather or temperatures below freezing.
  8. Do not operate the pump in water temperatures higher than 95° F.

B. The Simple Deluxe pump should not be used if:

  1. Do not operate the pump if the power supply cord, plug, or any other parts have any damage
  2. If cord is damaged, the pump should not be used and disposed of properly
  3. Pump has a wet plug or a wet receptacle.
  4.  Water discharge from the pump is reduced
  5. Apart is broken and water leaks in.
  6. Anything abnormal occurs.
  7. If people or body parts are in the water

C. During Simple Deluxe pump operation:

  1.  Shut off the power immediately to prevent the motor from burning out when overloaded due to clogging
    from foreign materials

  2. Please consult Simple Deluxe if the pump is not working properly. DO NOT disassemble or assemble the pump, as this may result in severe damage.

DRIP LOOP;
ALWAYS SET UP A DRIP LOOP
Ensure that the electrical cord loops below the electrical outlet to form a Drip Loop” This will prevent water from running down the cord into the electrical outlet.

Deluxe Submersible Pump OperationALWAYS SET UP

Specifications

LGPUMP80G

product#

| Voltage| Amps| Watts| Flow Rate (G/H)|  Max lift Height| Dimensions (Inch)| Cord Length
---|---|---|---|---|---|---|---
LGPUMP80G| 120V/60Hz| 0.03| 3.6W| 80GPH| 2.2ft| 197×173 x 126|

6f

Deluxe Submersible Pump Operation LGPUMP120G 1

LGPUMP120G

product#| Voltage| Amps| Watts| Flow Rate (G/H)|  Max lift Height| Dimensions (Inch)| Cord Length
---|---|---|---|---|---|---|---
LGPUMP120G| 120V/60Hz| 0.08| 9.8W| 120GPH| 3.1 ft| 256x165x195| 6f

Deluxe Submersible Pump Operation LGPUMP120GLGPUMP160G.

product#

| Voltage| Amps| Watts| Flow Rate (G/H)|  Max lift Height| Dimensions (Inch)| Cord

Length

---|---|---|---|---|---|---|---
LGPUMP160G| 120V/60Hz| 0.195| 234 W| 160GPH| 4.3 ft| 366x205x246|

6f

Deluxe Submersible Pump Operation LGPUMP160G

LGPUMP290G

product#| Voltage| Amps| Watts| Flow Rate (G/H)|  Max lift Height| Dimensions (Inch)| Cord Length
---|---|---|---|---|---|---|---
LGPUMP290G| 120V/60Hz| 0.24| 28.8 W| 290GPH| 6.3 ft| 457x225x295|

6f

Deluxe Submersible Pump OperationLGPUMP290GLGPUMP400G

product#| Voltage| Amps| Watts| Flow Rate (G/H)|  Max lift Height| Dimensions (Inch)| Cord

Length

---|---|---|---|---|---|---|---
LGPUMP400G| 120V/60Hz| 0.45| 54 W| 400 GPH| 8.2 ft| 5.35×2.72 x 3.39|

15ft

Deluxe Submersible Pump OperationLGPUMP290G

LGPUMP1056G

product#

| Voltage| Amps| Watts| Flow Rate (G/H)|  Max lift Height| Dimensions

(Inch)

| Cord

Length

---|---|---|---|---|---|---|---
LGPUMP1056G| 120V/60Hz| 2.30| 276 W| 1056 GPH| 12 ft| 8.3×4.647.08|

15 ft

Deluxe Submersible Pump Operation LGPUMP1056G