Wi‐Fi module can enable wireless communication between hybrid inverters and monitoring platforms. Simply put this module is connected to an inverter with a communication cable and installs the APP from Google Play or Apple stores, it can not only monitor the inverters’ operation status but also set up parameters of the inverters through your mobile phone.
The major functions of this APP:
- Delivers device status during normal operation.
- Allows configuring device settings after installation.
- Notifies users when a warning or alarm occurs.
- Allows users to query inverter history data.
Unpack and Overview
Packing list
Before installation, please inspect the unit. Be sure that nothing inside the
package is damaged. You should have received the following items inside of the
package:
Product overview
**** Wi‐Fi Module x 1
User’s Manual x 1
-
Antenna
-
Inverter connection status LED
OFF : Inverter does not power to Wi‐Fi module.
ON: Inverter powered to Wi‐Fi module successfully. -
PWR: To indicate if the power is on.
COM : To indicate if communication between the Wi‐Fi module and the Inverter is normal.
NET: To indicate if the Wi‐Fi module is connected to the router.
SRV: To indicate if the Wi‐Fi module is connected to the internet.
Wi‐Fi Module Installation
Please follow the below steps to install the Wi‐Fi module:
Step 1 : The module contains four strong magnetic backings and can be
easily be placed on the side of the inverter.
Step 2: Please use one RJ45 to RS‐232 communication cable to connect an
inverter and Wi‐Fi module as below chart.
SolarPower App Installation
Download and install APP
Operating system requirement for your smartphone:
iOS system supports iOS 9.0 and above
Android system supports Android 5.0 and above
Please scan the following QR code with your smartphone and download SolarPower
App.https://play.google.com/store/apps/details?id=wifiapp.volfw.solarpower
Android system
https://apps.apple.com/us/app/id1491698936
iOS system
Or you may find the “SolarPower Wi‐Fi” app from the Apple® Store or
“SolarPower” in Google® Play Store.
Initial Setup
Step 1: Registration at the first time
After the installation, please tap the shortcut icon to access the APP on your mobile screen. On the screen, tap “Register” to access the “User Registration” page. Fill out all required information accordingly. You can scan the Wi-Fi Module PN by tapping the icon Tap “Register” after you have completed the registration.
Then, a “Registration success” window will pop up. Tap “Go now” to continue
setting local Wi‐Fi network connection. Step 2 : Local Wi‐Fi Network
Configuration
Now, you are on the “Wi‐Fi Config” page. There are detailed setup
procedures listed in the “How to connect?” section and you may follow it to
connect Wi-Fi.
Enter the “Settings Wi‐Fi” and select the connected Wi‐Fi name. The connected Wi‐Fi name is the same as your Wi-Fi PN number and enters the default password “12345678”.
Then, return to SolarPower APP and tap the “ ” button when Wi‐Fi Model is
connected successfully.
Step 3 : Wi‐Fi Network settings
Tap the icon to select your local Wi‐Fi router name (to access the internet)
and enter a password
Step 4: Tap “Confirm” to complete the Wi‐Fi configuration between the Wi‐Fi Module and the Internet.
If the connection fails, please repeat Steps 2 and 3.
Step 5: Diagnose Function
If the module is not monitoring properly, please tap “ ” on the top right
corner of the screen for further details. It will show repair suggestions.
Please follow it to fix the problem. Then, repeat the steps in chapter 4.2 to
re-set the network setting. After all settings, tap “Rediagnosis” to
re‐connect again.
Login and APP Main Function
After finishing the registration and local Wi‐Fi configuration, enter the
registered name and password to log in Note : Tick “Remember Me” for your
login convenience afterward.
SolarPower APP
Operation
Overview
After the login is successful, you can access the “Overview” page to have an
overview of your monitoring devices, including operation status (normal,
offline, alarm, and fault) as below diagram.
Devices
Tap the icon, you can enter the Device List page. You can review all of the
devices in “Device List”. You also can add or delete Wi‐Fi Module on this
page.
Add device Delete device
Tap the icon on the top right corner and enter a part number by scanning the bar code to add the Wi‐Fi module. This part number is printed on the Wi‐Fi module’s surface or manually enter. Tap “Confirm” to add the Wi‐Fi module to the Device List. Time zone and Wi‐Fi module PN are required information. Tap “Confirm” to complete and the added Wi‐Fi module can be reviewed in the Device list.
5‐3. ME
On the ME page, users can modify “My information”, including【User’s Photo】,
【Account security】, 【About】,【Clear cache】 and【Log‐out】, shown as below
diagrams.
Device List
On the Device List page, you can pull down to refresh the device information and then tap any device you want to check up for its real‐time status and related information as well as to change parameter settings. Please refer to
Monitoring Information and Parameter Setting
Device Mode
On the top of the screen, there is a dynamic power flow chart to show live operation. It contains five icons to present PV power, inverter, load, utility, and battery. Based on your inverter status, there will be【Standby Mode】, 【Line Mode】, and 【Battery Mode】. 【Standby Mode】Inverter will not power the load until the “ON” switch is pressed. Qualified utility or PV power can charge the battery in standby mode.
【Line Mode】 Inverter will power the load from the utility with or without PV power. Qualified utility or PV power can charge the battery
【Battery Mode】Inverter will power the load from the battery with or without PV power. Only PV power can charge the battery at this mode.
Device Alarm and Name Modification
On this page, tap the icon on the top right corner to enter the device alarm
page. Then, you can review the alarm history and detailed information.
After tapping the icon on the top right corner, a blank input column will pop
up. Then, you can edit the name for your device and tap “Confirm” to complete
the name modification.
Device Information Data
Users can check up 【Basic Information】,【Product Information】,【Rated
information】,【History】 and【Wi‐ Fi Module Information】by swiping left.
【 Basic Information 】displays basic information about the inverter,
including AC voltage, AC frequency, PV input voltage, Battery voltage,
Battery capacity, Charging current, Discharge current, Output voltage,
Output frequency, Output apparent power, Output active power, and Load
percent. Please slide up to see more basic information.
【Production Information 】displays Model type (Inverter type), Main CPU
version, Bluetooth CPU version, and secondary CPU version.
【 Rated Information 】 displays information on Nominal AC voltage,
Nominal AC current, Rated battery voltage, Nominal output voltage,
Nominal output frequency, Nominal output current, Nominal output apparent
power, and Nominal output active power. Please slide up to see more rated
information.
【 History 】displays the records of unit information and setting.
【 Wi‐Fi Module Information 】displays of Wi‐Fi Module PN, status, and
firmware version.
Parameter Setting
This page is to activate some features and set up parameters for inverters. Please be noted that the listing in the “Parameter Setting” page in the below diagram may differ from the models of monitored inverters. Here is briefly illustrate partial setting:【 Output Setting】,【Battery Parameter Setting 】, 【 Enable/ Disable items】,【Others Settings】, 【Restore to the defaults 】 Please refer to the product manual when necessary.
There are three ways
to modify settings and they vary according to each parameter.
a) Listing options to change values by tapping one of them.
b) Activate/Shut down functions by clicking the “Enable” or “Disable” button.
c) Changing values by clicking arrows or entering the numbers directly in the
column.
Each function setting is saved by clicking the “Set” button.
Please refer to below parameter setting list for an overall description and be
noted that the available parameters may vary depending on different models.
Please always see the original product manual for detailed setting
instructions.
Parameter setting list:
Item
|
Description
---|---
**** Output Setting| Output Source Priority| Output source priority selection
Input Voltage Range| Input voltage range selection
AC Output Rating Voltage| To set output rating voltage
AC Output Rating Frequency| To set output rating frequency
Item
|
Description
---|---
Battery Parameters Setting
| Battery Type| Select connected battery type
Battery Cut‐off Voltage| Set battery cut‐off voltage
Bulk Charging Voltage| Set battery bulk charging voltage
Battery Float Voltage| Set battery floating charging voltage
Max Charging Current| To configure total charging current for solar and
utility chargers.
Max AC Charging Current| Set maximum utility charging current
Charging Source Priority| To configure charger source priority
Back To Grid Voltage| Set battery voltage to stop discharging when the grid is
available
Back To Discharge Voltage| Set battery voltage to stop charging when the grid
is available
Enable/Disable Items
| Overload Auto Restart| If disabled, the unit won’t be restarted after
overload occurs.
Overload Temperature Auto Restart| If disabled, the unit won’t be restarted
after the over‐temperature fault is solved.
Overload Bypass| If enabled, the unit will enter bypass mode when an overload
occurs.
Beeps While Primary Source Interrupt| If enabled, the buzzer will alarm when
the primary source is abnormal.
Buzzer| If disabled, the buzzer won’t be on when the alarm/fault occurred.
Backlight| If disabled, the LCD backlight will be off when the panel button is
not operated for 1 minute.
LCD Screen Return To Default Display| If selected, no matter how users switch
display screen, it will automatically return to the default display screen
(Input voltage /output voltage) after no button is pressed for 1 minute.
Fault Code Record| If enabled, fault code will be recorded in the inverter
when any fault happens.
Item
|
Description
---|---
Others Settings
| Solar Supply Priority| Set solar power as a priority to charge the battery
or to power the load.
Reset PV Energy Storage| If clicked, PV energy storage data will be reset.
Start Time For Enable AC Charge Working| The setting range of start charging
time for AC chargers is from 00:00 to 23:00. The increment of each click is 1
hour.
Ending Time For Enable AC Charge Working| The setting range of stop charging
time for AC chargers is from 00:00 to 23:00. The increment of each click is 1
hour.
Scheduled Time For AC Output On| The setting range of scheduled time for AC
output is from 00:00 to 23:00. The increment of each click is 1 hour.
Scheduled Time For AC Output Off| The setting range of scheduled time for AC
output off is from 00:00 to 23:00. The increment of each click is 1 hour.
Country Customized Regulations| Select inverter installed area to meet
local regulations.
Set Date Time| Set date time.
Restore to the defaults| This function is to restore all settings back to
default settings.
References
- Enhanced Range Digital Audio Baby Monitor with 2 Parent Units | DM1211-2 | VTech® Cordless Phones
- VTech Canada Official Site | Best Home Office & Business Phones
- RM5762 - Mobile App Manual - VTech
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>