Drok General Programmable Battery Power Display Instructions
- June 7, 2024
- Drok
Table of Contents
JS-C33 General Programmable Battery Power Display
Instructions
SUMMARY:
This product is a general instrument, adopts LCD color screen, can long-term display the battery, voltage, temperature (Selective assembly; sound-light alarm (Selective assembly) can be used in a variety of lighting conditions. The default parameters are suitable for lithium batteries, lead-acid batteries, lithium iron phosphate battery, Ni MH battery application field; through the development of programming, can be applied to any battery, simple wiring, convenient maintenance, and disassembly using a standard connector.
FEATURES:
- The patented product adopted neutral packaging production, with the simple dustproof waterproof surface, with a full protection cover.
- The color liquid crystal material, clear display, display softly at night.
- To customize the type of battery, suitable for lead-acid, lithium-ion batteries, lithium iron phosphate, metal hydride battery, etc.
- To display the percentage of remaining battery power, voltage, temperature.
- The 10~100V wide input voltage, reverse protection.
- The product can go to sleep after 10 seconds.
- The red indicator flashes to alarm when it is low battery.
- The installation is simple, with a buckle, without screws.
- The buzzer alarm switch, alarm voltage setting (Selective assembly).
- The real-time detection of the battery temperature (Selective assembly).
- Open programming mode
PARAMETER:
Parameter | Min | Typical | Max | Unit | Figure |
---|---|---|---|---|---|
Product size | mm | 61.533.513.5 | |||
Installation size | mm | 58.5*28.5 | |||
Display size | mm | 36*19.5 | |||
Weight | 20 | 21 | 22 | g | |
Working voltage | 10 | 100 | V | Common | |
Working consumption | 5 | 6 | mA | LED ON | |
Voltage accuracy | ±0.1 | ±0.5 | % | ||
Temperature accuracy | ±0.5 | ±1 | °C | Selective assembly | |
Sleep consumption | 6 | 10 | 12 | uA | 20V |
Working temperature | -10 | 25 | 55 | °C | |
Buzzer volume | 70 | 75 | 80 | db | Selective assembly |
Buzzer voltage | 11.5 | 100 | V | adjustable |
INSTRUCTIONS:
- PH2.0 terminal conductor, connected to PCB opposite connector
- External NTC temperature sensor, please put the sensor to measure the temperature of the parts, do not squeeze the sensor (selective assembly).
- Redline to the positive terminal, black line to the negative terminal.
- After the instrument is powered on, it shows the percentage of the battery power, the voltage, and the battery icon.
- Press to turn off the instrument. In close status, you can wake up the instrument by pressing any button.
- Press in the working status, you can switch the voltage and temperature to display.
- The battery icon on the display interface, from the right to the left, are 7 display boxes representing the battery power from low to high.
- The voltage on the display interface is measured in real-time, and the voltage value is displayed on 10-100V.
- The percentage on the display interface is the percentage of the remaining battery power.
- When the battery is connected to the charger or the discharge of the large current load, the display parameters will fluctuate
- The red lightning flashes the alarm when the battery is low
- Low voltage buzzer alarm (Selective assembly)
- If the battery specification is special, you can enter the programmable mode 3– and reset the upper and lower limits of the battery.
Go into programming mode:
- Power-on status, press last about 5 seconds, enter the main menu, as shown in Figure P2.
- The main menu has 5 sub-menus: 1–, 2–, 3–, 4–, 5–.
- Press , and the 5 submenu loops.
- Each function of the 5 sub-menu:
1- -: Select built-in preset battery specification: lithium battery, lead-acid battery, LFP battery.
2- -: Setting Delay Time Delay OFF/ON, and select Delay Time
3- -: The voltage of percentage 0 to 100 could be customed.
4- -: Buzzer switch and alarm value setting.
5- -: Calibrate the instrument voltage again.
5.Press , select the menu to enter, long press to quit.
6.All parameters are subject to the last save.
Submenu functions explanation:
1- -: Quick change battery type
Under this menu, you can change the default parameters speedy: L represents
the lithium battery, and the latter figure is the series quantity;
F represents the lithium iron phosphate battery, and the latter figure is the
series quantity;
P stands for lead-acid batteries, and the numbers behind represent voltage.
Setting steps:
Enter the menu 1–, as shown in P3, and display 1–L/P/F xx, press to switch
among L, P, and F. Press to select the appropriate battery specifications,
enter L/F to select the battery series quantity. Long press to save after
finishing selection. If you don’t need to change other parameters, long press
to quit.
E.g.
L3 represents 3 string lithium 4.2V3S=12.6V.
L7 represents 4 string lithium 4.2V7S=29.4V.
F4 represents 4 string lithium iron phosphate battery 3.2V4S=12.8V.
F8 represents 8 string lithium iron phosphate battery 3.2V8S=25.6V.
P12V stands for lead-acid 12V batteries.
P24V stands for lead-acid 24V batteries.
Note: Please set parameters according to the battery
specifications, otherwise, the percentage value is inaccurate; the voltage
value is accurate.
All parameters are subject to the last save.
2- -: Delay ON-OFF, Delay time setting
On this menu, delay OFF and the delay time can be set, as shown in P4:
Left side to switch ON or OFF; Right side select the delay time (10/30/60/120
unit:S)
Setting steps: Enter
the menu 2–,
Press to change the parameters, press to carry bits. press to save parameters. If you don’t need to change other parameters, press to quit.
Note : D symbol light on after turning on the delay function. If the switch is OFF, the delay function will be invalid.
3- -: The voltage of percentage 0 to 100 could be customize
The menu customizes the percentage of the upper and lower voltage, and after
changing this parameter, the product can be applied to nickel-hydrogen, fuel
cells and Enter the menu 3–,as shown in P5 : Left side is power 0%, represents
the low battery voltage.
The right side is power 100%, represents the full battery voltage.
Setting steps: Enter the menu 3–,
Press to adjust the setting voltage. Press to carry, press to save
parameters.
If you don’t need to change other parameters, press to quit.
Notes : The input value must not exceed the instrument working to the value on the right side, the save is invalid. voltage. If the value on the left side is greater than or equal to the value on the right side, the save is invalid.
4- -: Buzzer alarm value setting and ON/OFF
This menu customizes buzzer working voltage and red alarm value.
Enter menu 4–,as shown in P6:
The left side is the buzzer ON/OFF status. The left side is for setting buzzer
alarm voltage.
Setting steps :
Enter menu 4–, press to take the buzzer ON or OFF, press to carry, long press
to save. If you don’t need to change other parameters, press to quit.
Notes : When the buzzer works, the red lightning symbol flashes in sync.
If the switch is OFF, it will be no working.
5- -: Calibrate the instrument voltage again
Enter menu 5–, as shown in P7: Before entering the calibration interface,
please provide an accurate 20V operating voltage for the instrument.
To prevent misoperation, long press to enter the menu in 5– status, and then
the meter will be automatically calibrated according to the supplied voltage.
But it cannot be calibrated if the voltage range is not between 19 and 20V.
Notes : Please provide an accurate 20V operating voltage for the
instrument to ensure correct calibration, otherwise, the error will be bigger.
When the calibration is complete, the instrument will automatically exit this
menu and display the normal working interface.
SIZE: (mm)
Note: The best panel thickness is 2-3mm, please adjust the slotted size according to the panel material properly.