DROK 200386 AC Digital Meter Owner’s Manual
- June 16, 2024
- Drok
Table of Contents
http://www.Droking.com
SKU:200386/200677
Specifications
Parameters:
Working Voltage: 80~260VAC
Testing Voltage: 80~260VAC
Rated Power: 100A/22000W
Working Frequency: 45~65Hz
Measuring Accuracy: 1.0 grade
Power:
Measurement Range: 0~22000W
The Minimum Testing Power: 0.5W
When the power is lower than 10W, the display format will be 1.00~9.99W.
When the power is lower than 100W, the display format will be 10.0v99.9W.
When the power is lower than 1000W, the display format will be 100~999W.
When the power is lower than 10000W, the display format will be 1.00~9.90k\W.
When the power is equal to or higher than 10000W, the display format will
be 10.0~22.0kW.
Energy Consumption:
Measurement Range: 0~999kWh
When itis lower than 1kWh, the display format will be 0~999Wh.
When itis lower than 10kWh, the display format will be 1.00~9.99kWh.
When itis equal to or higher than 10kWh, the display format will be
10~999kWh.
Voltage:
Measurement Range: 80~260V
Display Format: 80~260V
Current:
Measurement Range: 0~100A
The Minimum Testing Current: 0.02A
When the current is lower than 10A, the display format will be 0.000~9.000A
When the current is equal to or higher than 10A, the display format will be
10.00~99.99A
Frequency:
Measurement Range: 45~65Hz
Display Format: 45~65Hz
Power Factor:
Measurement Range: 0~1PF
Display Format: 0.00~1.00PF
Display Function
Function & Instructions
Backlight Control:
You can shortly press the button to turn on or turn off the backlight and the
state will be automatically saved when power off.
Quantity of Electricity Reset:
Step1: Long press the button by 5 seconds until the figure of electric energy
is flashing, and stop pressing button.
Step2: If shortly press the button again, the quantity of electricity data
will reset and exit flashing sate
Step3: If no action is done within 5 seconds, the quantity of electricity will
not reset and exit flashing sate
Power Alarm Value Setting:
Step 1: Long press the button by 3 seconds until the screen displays “SET
CLr”, and stop pressing. Now it enters into setting state of power alarm
value.
Step 2: When power area displays the current power alarm value and the minimum
digit starts flashing, at this time you can add 1 to this digit by shortly
pressing button: If no action is done over 3 seconds, it can automatically
switch digit and the setting method is the same as above
Step 3: After you finish the setting, by long pressing button over 5 seconds,
the setting will be saved automatically and exit. The setting range of
effective power is 0.0~2.2kW.
Wiring Diagram
Cut – Out