Heatit controls Heatit ZM Thermostat 16A ZM Thermostat 16A Manual

June 8, 2024
heatit CONTROLS

Heatit controls

Heatit ZM Thermostat 16A

SKU: ZM Thermostat 16A

Quickstart

This is a
secure
HVAC-Thermostat
for
.

To run this device please connect it to your mains power supply.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

Heatit ZM Thermostat is an electronic thermostat for electrical floor heating designed for in-wall installations. The thermostat allows you to control your electrical heating through your Z-Wave network. The module is equipped with a 16A single pole relay. The thermostat requires you to connect an external sensor which is included with the device.The device can withstand a max load of 16A at 230VAC.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 5 Lifeline. (Normally used by the Z-Wave Controller) Sends
2 5 Send Binary Switch set commands representing the status of the internal

relay.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Operating mode

Set the thermostat mode
Size: 1 Byte, Default Value: 1

SettingDescription

0 Off, Thermostat will not operate
1 Heating, Thermostat mode is in heating mode
2 Cooling, Thermostat mode is in cooling mode

Parameter 10: Inverted output

Decides if the relay output should be inverted
Size: 1 Byte, Default Value: 0

SettingDescription

0 Standard output
1 Inverted output

Parameter 11: Relay state update interval

Set the time interval of how often the device reports Binary Switch Set and thermostat mode
Size: 2 Byte, Default Value: 43200

SettingDescription

30 – 65535| 30 seconds65 535 Seconds, Time interval between consecutive temperature reports
---|---

Parameter 2: Temperature control hysteresis

Choose the hysteresis for the thermostat
Size: 1 Byte, Default Value: 5

SettingDescription

3 – 30 0,3C to 3,0C,Chose the hysteresis for the thermostat.

Parameter 3: Minimum setpoint temperature

Decide the lowest setpoint temperature allowed by the thermostat
Size: 2 Byte, Default Value: 50

SettingDescription

50 – 400| 5,0C to 40,0C,Set the minimum setpoint temperature for the thermostat
---|---

Parameter 4: Maximum setpoint temperature

Decide the highest setpoint temperature allowed by the thermostat
Size: 2 Byte, Default Value: 400

SettingDescription

50 – 400| 5,0C to 40,0C,Set the maximum setpoint temperature for the thermostat
---|---

Parameter 5: Setpoint

Decide the thermostat setpoint
Size: 2 Byte, Default Value: 210

SettingDescription

50 – 400 5,0C to 40,0C,Set the setpoint temperature for the thermostat

Parameter 6: Sensor calibration

Manually calibrate the sensor 6C
Size: 1 Byte, Default Value: 0

SettingDescription

-60 – 60 -6,0C to 6,0CCalibrate the sensor 6C NB! To set a negative value, use 256 and subtract the desired value

Parameter 7: Temperature report interval

Time interval between consecutive temperature reports
Size: 2 Byte, Default Value: 1020

SettingDescription

30 – 65535| 30 seconds65 535 Seconds Time interval between consecutive temperature reports.
---|---

Parameter 8: Temperature report hysteresis

Temperature reports based on change in temperature from last report
Size: 1 Byte, Default Value: 10

SettingDescription

0 Temperature report based on delta value is disabled.
1 – 100 0,1C to 10C

Parameter 9: Meter report interval

Time interval between consecutive meter reports
Size: 2 Byte, Default Value: 1020

SettingDescription

30 – 65535| 30 seconds65 535 Seconds Time interval between consecutive meter reports.
---|---

Technical Data

Hardware Platform ZGM130
Device Type Thermostat – HVAC
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 7.15.4
Certification ID ZC12-21100317
Z-Wave Product Id 0x019B.0x0004.0x3502
Outdoor Use ok
Thermostat HVAC Systems Supported Cool OnlyHeat Only
Thermostat Modes CoolHeat
Neutral Wire Required ok
IP (Ingress Protection) Rated ok
Thermostat Power Source Mains powered (120V/240V)
Firmware Updatable Updatable by Consumer by RF
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info V3
  • Association V2
  • Basic V2
  • Configuration V4
  • Device Reset Locally
  • Firmware Update Md V5
  • Indicator V3
  • Manufacturer Specific V2
  • Meter V3
  • Multi Channel Association V3
  • Powerlevel
  • Security
  • Security 2
  • Sensor Multilevel V5
  • Supervision
  • Thermostat Mode V3
  • Thermostat Operating State
  • Thermostat Setpoint V3
  • Transport Service V2
  • Version V3
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)