DROK 200651 30V 4A 35W Buck Boost Converter Instruction Manual
- June 16, 2024
- Drok
Table of Contents
DROK DC Adjustable Buck Converter
DROK 30V 4A 35W Buck Boost Converter
Parameter
Input Voltage| DC 5.0-30V
Output Voltage| DC 0.6-30V
Output Current| 0-4.0A
Output Power| 35W (can reach to 50W with air cooling)
Voltage Resolution| 0.01V
Current Resolution| 0.001A
Voltage Accuracy| ±0.5% + 1 digit
Current Accuracy| ±0.5% + 3 digits
Conversion Efficiency| 88%
Soft Start| Yes
Protection
Reverse Connect Protection| Yes
Backflow Protection| Yes
Low Voltage Protection| Default 4.7V (4.7-30V Adjustable)
Over Voltage Protection| Default 32V (0-32V Adjustable)
Over Current Protection| Default 4.2A (0-4.2A Adjustable)
Over Power Protection| Default 36W (0-51W Adjustable)
Over Temperature Protection| Default 95°C/203°F
Over Time Protection| Default OFF (0-100H Adjustable)
Over Capacity Protection| Default OFF (0-9999AH Adjustable)
Over Energy Protection| Default OFF (0-9999WH Adjustable)
Overview
Working Interface
Setting Interface
Long press “SW” for 2 seconds to enter setting interface
Interface
Knob| **Working Interface
| Voltage Current Setting Interface
| Parameter Se
Setting Interface
**
---|---|---|---
| Short Press: Enter Voltage and Current Setting Interface
Long Press: None| Short Press: Switch the Set Voltage and Current Display
Long Press: Save Voltage and Current Setting and Exit| None
| Short Press: Switch Input/ Output Voltage Display
Long Press: Enter Parameter Setting Interface| Short Press: Set Voltage/
Current Shift Operation
Long Press: None| Short Press: Switch the Setting Parameter
Long Press: Save the Parameter and Exit
| Short Press: Turn ON/OFF Output
Long Press: Clear Capacity/ Energy/Timing Value| Short Press: Turn ON/OFF
Output
Long Press: None| Short Press: Open/
Close OAH/OWH/OHP Long Press: Switch OAH/ OWH/OHP
| Short Press: Switch Power Capacity Energy Timing Display
Long Press: Turn ON/OFF Key Lock Function| Short Press: Set Voltage/ Current
Shift Operation
Long Press: None| Short Press: Set Parameter Shift Operation
Long Press: None
| Adjust the Voltage/Current/ No action by default| Adjust Setting Voltage/
Current Value| Adjust Parameter Value
Operating Instruction
Setting Voltage Current
Inthe operation interface, short press to enter the setting voltage and
currentinterface. The bottom of LCD screen displays SET and CV flashing, short
press!:‘pr potentiometer knob to switch voltage selection, adjust the set
voltage through rotating the knob.
Press Aagain, the bottom of LCD screen displays SET and SW flashing, short.
pressFor potentiometer knob to switch current selection, adjust the set
current through rotating the knob. Short press again to save setting and exit
to the working interface. Long press for 2 seconds or wait for 6 seconds
without any operation, the system will automatically save the setting and exit
to the working interface.
Quick Set Voltage Current
Inthe parameter setting interface, set “FET” to CV or CC. Rotate the potentiometer knob in working interface, then enter the voltage current setting interface. Rotate the potentiometer knob again to quick set the voltage or current.
Setting Parameter
3.1 In the working interface, long press for 2 seconds to enter the parameter
setting interface.
3.2 Press to switch the parameter to be set, short press the potentiometer
knob to switch selection, rotate the potentiometer to adjust value.
3.3 In the OAH/OPH/OHP interface, short press to turn on/off OAH/OPH/OHP.
3.4 In the OAH/OPH interface, long press to choose measure range
(9.999AH/99.99AH/999.9AH/9999AH; 9.99WH/99.99WH/999.9WH/9999WH)
3.5 After parameter setting is completed, long press SW for 2 seconds to save
the parameter and exit.
Display Input/Output Voltage
Check Power(W)/Capacity(AH)/Energy(WH)/Time(H):
In the working interface, short press potentiometer knobto switch the display Power (W)/Capacity(AH)/Energy(WH)/Time(H)
Lock Function
In the working interface, long press the potentiometer for 2 seconds tolock the setvoltage and current. Then long press the potentiometer for 2 seconds again to unlock.
Other Function
7.1 Capacity/Energy/Working Time:
The Capacity/Energy/Working Time will be automatically measured after power
ON. After power OFF, the measurement will be temporarily stopped until next
time turn ON. In the corresponding interface, long press will clear the data.
7.2 Set the maximum Capacity(OAH)/maximum Energy(OPH)/maximum working
time(OHP)
7.2.1 Set OAH/OPH: OAH/OPH turn ON, when measured capacity/energy are higher
than the set maximum capacity/energy, output will automatically turn off and
flash “OAH”/“OPH”. After the alarm is lifted, data will be automatically
cleared.
7.2.2 Set the maximum working time(OHP): OHP turn ON, when working time is
higher than the maximum working time, output will automatically turn off and
flash “OHP”. After the alarm is lifted, data will be automatically cleared.
These functions can achieve a regular and quantitative power supply.
Note: if OAP/OPH/OHP are off, the meter will also record the
capacity/energy/working time. After OHP is on, the working time will display
as countdown mode.