GENERAC Guardian Series Air-Colled Gas Engine User Guide

June 7, 2024
Generac

logo

GENERAC Guardian Series Air-Colled Gas Engine

product

INCLUDES:

True Power™ Electrical Technology

  • Two Line LCD Multilingual DigitalEvolution™ Controller (English/Spanish/ French/Portuguese)
  • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 5 for Details.
  • Electronic Governor
  • Standard Wi-Fi™ Remote Monitoring
  • System Status & Maintenance Interval LED Indicators
  • Sound Attenuated Enclosure
  • Flexible Fuel Line Connector
  • Direct-To-Dirt Composite Mounting Pad
  • Natural Gas or LP Gas Operation
  • 5 Year Limited Warranty
  • Listed and Labeled by the Southwest Research Institute allowing installation as close as 18″ (457 mm) to a structure.**Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. https://assets.swri.org/library/DirectoryOfListedProducts/ConstructionIndustry/ 973_DoC_204_13204-01-01_Rev9.pdf

FEATURES

INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING
are at the heart of Generac’ssuccess in providing the most reliable generators possible. Generac’s G-Force enginelineup offers added peace of mind and reliability for when you need it the most. TheG-Force series engines are purpose built and designed to handle the rigors ofextended run times in high temperatures and extreme operating conditions.

SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:

This state-of-the-art power maximizing regulation system is standard onall Generac models. It provides optimized FAST RESPONSE to changingload conditions and MAXIMUM MOTOR STARTING CAPABILITY byelectronically torque-matching the surge loads to the engine. Digitalvoltage regulation at ±1%.

TRUE POWER™ ELECTRICAL TECHNOLOGY:

Superior harmonics and sine waveform produce less than 5% Total Harmonic Distortion for utility quality power. This allowsconfident operation of sensitive electronic equipment and micro-chip based appliances,such as variable speed HVAC systems.

SINGLE SOURCE SERVICE RESPONSE

from Generac’s extensive dealernetwork provides parts and service know-how for the entire unit, from theengine to the smallest electronic component.

TEST CRITERIA:

  • PROTOTYPE TESTED
  • NEMA MG1-22 EVALUATION
  • SYSTEM TORSIONAL TESTED
  • MOTOR STARTING ABILITY

GENERAC TRANSFER SWITCHES:

Long life and reliability aresynonymous with GENERAC POWER SYSTEMS. One reason for thisconfidence is that the GENERAC product line includes its own transfersystems and controls for total system compatibility.

MOBILE LINK™ REMOTE MONITORING: FREE

with every Guardian Series Homestandby generator. Allows you to monitor the status of your generator from anywhere in theworld using a smartphone, tablet, or PC. Easily access information such as the currentoperating status and maintenance alerts. Connect your account to your authorized servicedealer for fast, friendly and proactive service. With Mobile Link, you are taken care of beforethe next power outage.

TMNote: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified in the USA only.

features and benefits

Engine

  • Generac G-Force design Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma molyrings helps the engine run cooler, reducing oil consumption resulting in longer engine life.
  • “Spiny-lok” cast iron cylinder walls Rigid construction and added durability provide long engine life.
  • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time.
  • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval.
  • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil.
  • High temperature shutdown Prevents damage due to overheating.

Generator

  • Revolving field: Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
  • Skewed stator : Produces a smooth output waveform for compatibility with electronic equipment.
  • Displaced phase excitation: Maximizes motor starting capability.
  • Automatic voltage regulatio n Regulates the output voltage to ±1% prevents damaging voltage spikes.
  • UL 2200 listed: For your safety.

Transfer Switch (if applicable)

  • Fully automatic: Transfers your vital electrical loads to the energized source of power.
  • NEMA 3R: Can be installed inside or outside for maximum flexibility.
  • Remote mounting: Mounts near your existing distribution panel for simple, low-cost installation.

Evolution™ Controls

  • Auto/Manual/Off illuminated buttons: Selects the operating mode and provides easy, at-a-glance status indication in any condition.
  • Two-line LCD multilingual display: Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
  • Sealed, raised buttons: Smooth, weather-resistant user interface for programming and operations.
  • Utility voltage sensing: Constantly monitors utility voltage, set points 65% dropout, 80% pick-up, of standard voltage.
  • Generator voltage sensing: Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
  • Utility interrupt delay: Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting offive (5) seconds by a qualified dealer.
  • Engine warm-up Ensures engine is ready to assume the load, set point approximately 5 seconds.
  • Engine cool-down Allows engine to cool prior to shutdown, set point approximately 1 minute.
  • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner.
  • Smart battery charger: Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries.
  • Main line circuit breaker: Protects generator from overload.
  • Electronic governor: Maintains constant 60 Hz frequency.

Unit

  • SAE weather protective enclosure: Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
  • Enclosed critical grade muffler: Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
  • Small, compact, attractive: Makes for an easy, eye appealing installation, as close as 18″ (457 mm) away from a building.16/20/22 kW.

Installation System

  • 1 ft (305 mm) flexible fuel line connector: Absorbs any generator vibration when connected to rigid pipe.
  • Direct-to-dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system.
  • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.

Remote Monitoring

  • Ability to view generator status: Monitor your generator via your smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind
  • Ability to view generator Exercise/Run and Total Hours: Review the generator’s complete protection profile for exercise hours and total hours
  • Ability to view generator maintenance information: Provides maintenance information for your specific model generator when scheduled maintenance is due
  • Monthly report with previous month’s activity. Detailed monthly reports provide historical generator information
  • Ability to view generator battery information: Built in battery diagnostics displaying current state of the battery.
  • Weather information: Provides detailed local ambient weather conditions for generator location.

Generator

specifications*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions – Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). Maximum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 °F) above 16 °C (60 °F).16/20/22 kW

specifications

Generator

table 1

Enginetable 2

Controlstable 3

Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions – Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 °F) above 16 °C (60 °F).16/20/22 kW.

Limited Circuits Switch Features

  • 16 space, 24 circuit, breakers not included.
  • Electrically operated, mechanically-held contacts for fast, positive connections
  • Rated for all classes of load, 100% equipment rated, both inductive and resistive.
  • 2-pole, 250 VAC contactors.
  • 30 millisecond transfer time.
  • Dual coil design.
  • Rated for both copper and aluminum conductors.
  • Main contacts are silver plated or silver alloy to resist welding and sticking.
  • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility.
  • Multi listed for use with 1″ standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effective install.

Dimensionstable 6

switch optionstable 4

*Function of Evolution Controller Exercise can be set to weekly or monthly.table 5

image 1 Service Rated Smart Switch Features

  • Includes Digital Power Management Technology standard (DPM).
  • Intelligently manages up to four air conditioner loads with no additional hardware.
  • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs)
  • Electrically operated, mechanically-held contacts for fast, clean connections.
  • Rated for all classes of load, 100% equipment rated, both inductive and resistive.
  • 2-pole, 250 VAC contactors.
  • Service equipment rated, dual coil design.
  • Rated for both aluminum and copper conductors.
  • Main contacts are silver plated or silver alloy to resist welding and sticking.
  • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility.image 2

available accessoriestable 7

dimensions & UPCs

Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.

image 3

Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.comlogo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals