MARVEL MPBV424 24 Inch Professional Series Beverage Center Owner’s Manual
- June 3, 2024
- Marvel
Table of Contents
OWNER’S GUIDE
MARVEL PROFESSIONAL UNDERCOUNTER REFRIGERATION FOR MODEL # MPBV424
MPBV424 24 Inch Professional Series Beverage Center
WELCOME
Welcome to the Marvel Experience!
Thank you for choosing our quality American-built product to add to your home.
We are thrilled to welcome you to our growing community of Marvel owners, who
trust in our products and our support.
The information in this guide is intended to help you install and maintain
your new Marvel undercounter model to protect and prolong its lifetime.
We encourage you to contact our Technical Support team at
616-754-5601 with any questions.
Got a Marvelous Design?
We would love to see how your Marvel product looks in its new home. Send us
photos at
marketing@marvelrefrigeration.com
, and we might feature your Marvel home design on our website and social
media!
Bonus Third-Year Warranty Free with Product Registration
Your Marvel Professional product qualifies for a one-year extension of the
two-year warranty coverage from your date of purchase, free of charge. To take
advantage of this third-year warranty, be sure to reg-ister your product with
Marvel within 60 days from the date of purchase at
marvelrefrigeration.com and provide
proof of purchase.
Thank you again for investing in Marvel for your home!
Warranty Registration
It is important you send in your warranty registration card immediately after
taking delivery of your appliance or you can register online at
www.marvelrefrigeration.com.
The following information will be required when registering your appliance:
Service Number
Serial Number
Date of Purchase
Dealer’s name and address
Online registration available at
www.marvelrefrigeration.com
The service number and serial number can be found on the serial plate which
is located inside the cabinet on the left side near the top.
INTEGRATED PANEL DIMENSIONS
INTEGRATED PANEL INSTALLATION
Integrated door panel installation:
If you purchased an integrated panel model, your unit is equipped with
articulated hinges to allow fully integrated built-in installations. Custom
panel thicknesses of 5⁄8″ (15 mm) and 3⁄4″ (18 mm) are accommodated.
CAUTION
It is important to use the factory provided grille that came with the product
to assure proper air flow is maintained through the condenser. The use of a
custom grille is not recommended and will void the warranty.
WARNING
Integrated panel models are designed for use with built-in installations only.
Use in freestanding installations could result in personal injury.
Step 1: Removing the Door
Open the door and loosen the screws holding the hinges to the cabinet (2 at
the top and 2 at the bottom hinge). Do not remove the screws but loosen them
enough so the hinges can be slipped off of the screws when sliding the door to
the side.
WARNING
The articulated hinges have many pinch points. Carefully close / collapse the
hinges as soon as the door is removed from the cabinet.
With a helper, and being careful not to scratch the cabinet or the door, slide
the door to the side about 1⁄2 inch and remove the hinges and door from the
unit.
WARNING
Use extreme caution with the articulated hinges. The hinge is self closing and
many pinch points exist prior to built-in installation. Do not remove the
cabinet “Z” bracket from the top of the cabinet.
Step 2: Remove the door gasket
With the door laying on a flat surface and starting at a corner of the door
remove the magnetic door gasket from the interior side of the door, see Figure
17. Set the gasket aside on a flat surface.
There are 10 holes in the gasket retainer extrusions, (3 on each side and 2 at
the top and bottom which are used to fasten the panel to the front of the
door. The screws are provided in the literature pack along with the door lock,
which is provided on certain models.
|
---|---
Step 3: Cut and drill the integrated panel
Depending on your model cut the integrated door panel to the dimensions shown
in Figures 19 to 22. The window cut out is for glass door models only. If your
appliance has a lock also drill the lock hole in the panel, see Figure 25.
CAUTION
Weight of integrated door panel must not exceed 15 pounds (6.8 kg) for a solid
door model or 10 pounds (4.5 kg) for a glass door model.
Material Type | #10 Wood Screw |
---|---|
Hardwood | 1⁄8″ (3.2 mm) Diameter. Pilot Hole |
Softwood | 7⁄64 (2.8 mm) Diameter. Pilot Hole |
Table A
Step 4: Assemble the panel to the door
The preferred method of attaching the panel to the door is to clamp the panel
to the door so it cannot move while drilling the screw pilot holes. Use bar
clamps or “C” clamps with pads on the clamping surfaces that will not mar the
panel or the door. The custom integrated panel should be flush with the top of
the door and centered along the width of the door. See Figure 16a. Drill holes
through the gasket extrusion using the 10 holes as pilot holes. Use the drill
size from the chart in Table “A”, being careful not to drill through the front
surface of the panel. If the integrated panel is thinner than 5⁄8″ (16 mm)
thick shorter screws will have to be obtained. Fasten the panel to the door
with the 10 screws provided in the literature pack. (See Figure 25a). Remove
the clamps and replace the gasket in the gasket extrusion channels of the
door. Some force may be required to seat the gasket into the channels. Be sure
the gasket corners are seated properly.
Step 5: Assemble lock parts
Two (2) lock extensions are provided with the lock. Use the longer extension
for 3⁄4″ thick integrated panels and the shorter one for 5⁄8″ thick integrated
panels. Assemble the lock extension, cam stop washer, spring washer, and set
screw to the lock as shown in Figure 26 and 27.
Install this lock assembly into the lock hole in the integrated panel and
secure with the retaining nut on the back side with a 15 mm socket and
ratchet. Make sure the key slot in the front of the lock is vertical.
Step 6: Install lock cam
Attach the lock cam to the back of the lock assembly with the phillips head
screw provided. Orient the lock cam vertically when installing on the lock.
Step 7: Install the door
Carefully open the top and bottom hinges on the door being careful as there
are many pinch points. Place the hinges over the 4 screws in the cabinet, 2 at
the top and 2 at the
bottom and slide the door into position. Tighten the 4 hinge screws with a
phillips screwdriver. (See Figures 25 and 25a).
Step 8: Secure the cabinet
Use the #8 x 3⁄4″ black screws from the literature pack to secure the counter
top to the cabinet top through the holes in the cabinet “Z” bracket.
THE ORIGINAL REFRIGERATION EXPERTS SINCE 1892
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>