AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray Instruction Manual
- June 6, 2024
- AIR INNOVATIONS
Table of Contents
Clean Mist
Ultrasonic Humidifier With Aroma Tray
Instruction Manual CLEAN MIST™
ULTRASONIC HUMIDIFIER
WITH AROMA TRAY
Instruction Manual and Warranty Information
READ AND SAVE THESE INSTRUCTIONS
If you have a respiratory condition, please contact your physician prior to use.
FCC STATEMENT
Potential for Radio/Television interference
This device complies with Part 18 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation. This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 18 of the FCC rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation.
The product generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that the
interference will not occur in a particular installation. If the product does
cause harmful interference to radio or television reception, which can be
determined by turning the product on or off, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the product and the receiver.
- Connect the product into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS: Failure to follow all the instructions may result in electrical shock.
WARNING
-
This appliance has a polarized plug (one blade is wider than the other) as a safety feature. If the plug does not fit fully into the outlet, reverse the plug. If it still doesn’t fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
-
Before using the humidifier, extend the cord and inspect for any signs of damage; DO NOT use if the cord has been damaged.
-
Keep cord away from heated surfaces and out of the way, where it cannot be stepped on or tripped over.
-
NEVER use in an environment where explosive gases are present.
-
Place humidifier on a stable level surface; DO NOT place on carpet, next to
heating vents, under direct sunlight, in high-temperature areas, or near computers and electronic equipment. -
DO NOT place the humidifier directly on wood furniture or other surfaces which could get damaged by water.
-
DO NOT direct the mist against a wall or home appliances.
-
NEVER operate without water in the Tank; DO NOT use anything other than room temperature tap or distilled water.
-
NEVER add essential oils directly to the water, as this will damage the unit and void the warranty.
-
DO NOT touch the water in the Base during operation.
-
DO NOT expose or immerse the Base in water when cleaning.
-
DO NOT pour water into the base through the Air Outlet during cleaning and filling.
-
NEVER block the Air Outlet or intake or cover the unit when it’s in operation.
-
DO NOT use any attachments not provided with the unit.
-
Discontinue use if the humidifier makes loud noises or has a strange smell.
-
DO NOT attempt to repair or adjust the unit; servicing must be performed by professional or qualified personnel.
CAUTION
- Only operate when fully assembled; only use as intended and described in this manual.
- Keep out of reach of small children.
- Always insert plug securely into the power source.
- Unplug the unit and empty the Water Tank and Base before carrying/moving.
- Only unplug when the humidifier is turned off; ensure hands are dry.
- Always turn off the unit before removing, emptying, or filling the Water Tank.
- Perform regular maintenance of the Ultrasonic Nebulizer; NEVER scrape Nebulizer with a hard or sharp object.
- Dry the unit completely before storage; store in a cool, dry place.
- Do not drop, hit, or otherwise subject this product to excessive shock.
No More Dry Air
Thank you for choosing the Air Innovations® – Clean Mist™ Ultrasonic
Humidifier with Aroma Tray and congratulations on taking this important step
in improving the quality of air in your home or office. The Air Innovations® –
Clean Mist™ Ultrasonic Humidifier with Aroma Tray uses Ultrasonic Technology
to create humidity instantaneously while working silently to erase the
discomforts of dry air.
Unpacking
-
Carefully remove the humidifier from the box by pulling the Base of the unit (Do not take the unit out of the box by pulling the tank).
-
Remove the plastic bag from the humidifier.
-
Remove the Dual Directional Mist Nozzle from the bottom of the packaging.
*Follow directions to fill and operate the humidifier.
Specifications
Product Model| Power Consumption| Current| Rating Voltage|
Tank Capacity| Dimensions| Weight
---|---|---|---|---|---|---
MH-603| 30W| 0.4A| 110-120V~60Hz| 5.9L / 1.6
Gallons| L10.6” X W7.6”
X H14.5”| 3.7 Lbs.
Parts & Contents
1. Dual Directional Mist Nozzle | 8. Water Sensor |
---|---|
2. Handle | 9. Water Reservoir |
3. Water Tank | 10. Cleaning Brush |
4. Base | 11. Ceramic Filter |
5. Power/Mist Control Knob | 12. Tank Cap |
6. Ultrasonic Nebulizer | 13. Bottom Tank Handle |
7. Air Outlet | 14. Aroma Tray |
15. Aroma Pads
Filling The Water Tank
WARNING: Always unplug the unit before removing the Water Tank.
WARNING: DO NOT touch the water in the Base.
WARNING: NEVER fill the Water Tank from the top of the unit. Follow
Water Tank filling instructions in #4.
|
---|---
Remove Dual Directional Mist Nozzle prior to filling the Water Tank.| Lift the
Handle on top of the Water Tank to remove the humidifier from the Base.
|
Make sure the Handle is snapped back into place, then turn the Water Tank
upside down and remove the Tank Cap by turning it counterclockwise.| Filling
the Water Tank: Use clean, cool, tap water. WARNING: DO NOT use
extremely cold water, since it may temporarily reduce the mist output.
WARNING: NEVER fill with hot/warm water or use additives as this could
damage the unit and void the warranty. WARNING: WARNING: If you have hard
tap water use our Humidifier Demineralization Filters (available at www.Air-
Innovations.com) or use ONLY
filtered/distilled water.
|
Replace the Tank Cap by firmly turning clockwise until tight. Turn the Water
Tank upright and check the Tank Cap for leaks. If any water drips, remove the
Tank Cap and retighten. WARNING: DO NOT place Water Tank on the
humidifier Base if the cap is leaking.| Lift the Handle up and replace it on
the humidifier Base, make sure to follow the shape of the Water Tank and the
humidifier Base so that the tank sits level and is flush to the Base. Ensure
the tank is firmly seated.
Attach the Dual Directional Mist Nozzle to the top of the Water Tank. To easily control the direction of the mist simply position the Dual Directional Mist Nozzle to the desired direction as pictured to the left.
Operating Instructions
WARNING: DO NOT operate the humidifier without water in the tank.
WARNING: NEVER lift the tank off the Base while the unit is operating.
-
ON/OFF – Plug into a standard (120V AC) electrical outlet. Turn the Mist Control Knob clockwise until you hear a click and the “Humidity / Waterless” Indicator turns green. To turn OFF, turn the Mist Control Knob counterclockwise until you hear a click and the indicator turns OFF. Mist may not appear immediately; allow up to 15 minutes for the water in the tank to transfer to the Base.
-
Mist Output – The unit will turn ON with the lowest mist setting. Turn the Mist Control Knob clockwise to increase the mist output and turn the Mist Control Knob counterclockwise to decrease.
-
Dual Directional Mist Nozzle – Attach the Dual Directional Mist Nozzle to the top of the Water Tank and position the Nozzle in the desired direction.
-
Low Water – When the tank is out of the water the “Humidity / Waterless” Indicator will turn from green to red and the automatic safety shut-off will turn the Ultrasonic Nebulizer OFF. You may hear the fan for a few minutes, this is normal.
-
Aroma Tray – By inserting an Air Innovations Essential Oil Aroma Pad into the built-in Aroma Tray, you can transform your humidifier into an easy-to-use fragrance dispenser.
Visitwww.Air-Innovations.com to purchase additional Aroma Pads.
Weekly Cleaning & Care
WARNING: Before cleaning always turn the power off and unplug the unit
from the outlet.
WARNING: DO NOT rinse Base under the faucet. To clean, wipe the Base with
a soft cloth.
WARNING: DO NOT use any solvents or aggressive cleaning agents. Keep
water away from the Air Outlet.
WARNING: DO NOT tamper with the Water Sensor.
About White Dust -Use of high-mineral content water may cause a white mineral residue to accumulate on room surfaces near the humidifier. The mineral residue is commonly referred to as “White Dust”. The higher the mineral content (the harder your water is), the greater the potential for White Dust. The White Dust is not caused by a defect in the humidifier but is due only to minerals suspended in the water from your tap. WARNING: If you have hard tap water STOP using tap water and visit our website (www.Air- Innovations.com) to purchase our Humidifier Demineralization Filters or use ONLY filtered or distilled water.
Tank Cleaning – Remove the Mist Nozzle from the top of the Water Tank
then remove the Water Tank from the unit. Turn the tank upside down, unscrew
the Tank Cap and drain any water from the tank. Wipe the tank with a soft damp
cloth then rinse it with warm water inside and out.
Base Cleaning – Gently wipe the Base with a soft damp cloth.
White Dust Cleaning – If mineral deposits “White Dust” are evident around
the Ultrasonic Nebulizer a
and Water Sensor, clean these surfaces with a
soft cloth and a small amount of undiluted white vinegar. If necessary, mix a
solution of 50% white vinegar and 50% water and fill the Base with enough
solution to cover the Ultrasonic Nebulizer a. Allow it to soak for an hour,
and then use the provided brush to gently loosen build upon the Ultrasonic
Nebulizer b
. Put 1 cup of water in the Base and wipe clean with a soft
cloth.
WARNING: DO NOT rinse Base under the faucet.
Ceramic Water Filter Cleaning – Remove the Water Tank from the humidifier
base. Remove the Tank Cap c
and rinse Ceramic Filter thoroughly with tap
water d
, then replace on Water Tank.
Surface Cleaning – Clean all surfaces of the unit with a clean damp soft
cloth.
WARNING: When emptying the Water Reservoir on the Base, make sure that
the water is poured away from the Air Outlet e
. If water is poured into the
outlet it may damage the humidifier.
Storage
- Follow all cleaning instructions prior to storage.
- Dry all parts, including the inside of the Water Tank.
- Leave the Tank Cap partially loosened to prolong the life of the cap.
- Preferably store in its original box, in a dry place away from high temperatures.
- Follow all cleaning instructions after long periods of storage.
Troubleshooting
Problem | Solution |
---|---|
Weak or no mist output. | The water in the unit is too cold: Replace with cool |
but not cold water or set the output to High and wait 10-15 minutes.
The surface of the Ultrasonic Nebulizer is dirty: Clean Ultrasonic Nebulizer.
(see pg. 6 “White Dust Cleaning”)
Ultrasonic Nebulizer is not working: See Warranty.
White dust is forming on nearby furniture.| Hard tap water may deposit a
certain amount of dust. Visit our website (www.Air-Innovations.com) to
purchase Humidifier Demineralization Filters or use distilled water.
Water is leaking.| Water Tank Installation: Make sure the tank is correctly
attached. (see pg. 4 “Filling the Water Tank”)
A humidifier is not on a level surface: Place on a level surface.
Ceramic Filter Installation: Turn Fitter Tank Cap clockwise until tight.
Condensation is forming around humidifiers or windows.| The mist output level
is too high for room size: Decrease the mist output.
The direction of Dual Directional Mist Nozzle: Change the direction of the
nozzle.
Aroma Tray does not close.| Aroma Pad is not seated properly: Remove and
reinsert the pad.
Missing parts.| Call us toll-free at:
844-600-1370, Monday thru Friday 8:30
am to 5 pm EST.
Please reference model: MH-603
| Try These Other Great
Products For Your Life!|
---|---|---
Available at: www.ForLifeProducts.com, www
.Air-Innovations.com,
www.Pursfection.com,
www.RejuvenateProducts.com
1-YEAR WARRANTY – MH-603
Air Innovations® Clean Mist™ Ultrasonic Humidifier with Aroma Tray comes with a 1-year manufacturer’s warranty. If this unit should become defective within 1-year from the date of purchase, or if you have any questions or comments regarding replacements for any of our products, please contact us directly at:
Call us toll-free at 844-600-1370
Monday thru Friday 8:30 AM to 5:00 PM EST.
Visit us on the web at: www.Air-Innovations.com
e-mail us: sales@air-innovations.com
Or write us:
Air Innovations
Att: Quality Assurance Dept.
2301 SW 145th Ave.
Miramar, FL. 33027 USA
Please fill out the warranty card and
mail back to the above address.
Or, register your warranty online today.
Simply go to:
www.Air-Innovations.com
Please check here if you would not like to receive any solicitations from our company
THIS UNIT COMES WITH A 1-YEAR WARRANTY SUBJECT TO THE FOLLOWING
CONDITIONS:
In the first year, all repairs will be performed free of charge or the unit
will be replaced. This warranty is not transferable, it is valid only for the
original purchaser. This warranty will be voided if the unit is subjected to
unauthorized repair or impact damage. If you have any questions please call
toll-free: 844-600-1370. This warranty
gives you specific legal rights, and you may also have other rights which vary
from state to state.
Available In Additional Colors
Documents / Resources
| AIR
INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma
Tray
[pdf] Instruction Manual
Clean Mist Ultrasonic Humidifier With Aroma Tray
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>