AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray Instruction Manual

June 6, 2024
AIR INNOVATIONS

Clean Mist Ultrasonic Humidifier With Aroma Tray
Instruction ManualAIR INNOVATIONS Clean Mist Ultrasonic Humidifier With
Aroma Tray CLEAN MIST™ ULTRASONIC HUMIDIFIER
WITH AROMA TRAY
Instruction Manual and Warranty Information
READ AND SAVE THESE INSTRUCTIONS

If you have a respiratory condition, please contact your physician prior to use.

FCC STATEMENT

Potential for Radio/Television interference
This device complies with Part 18 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation. This product has been tested and found to comply with the  limits for a Class B digital device, pursuant to Part 18 of the FCC rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation.
The product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If the product does cause harmful interference to radio or  television reception, which can be determined by turning the product on or off, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the product and the receiver.
  • Connect the product into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
  • Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

SAFETY INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS: Failure to follow all the instructions may result in electrical shock.

WARNING

  • This appliance has a polarized plug (one blade is wider than the other) as a safety feature. If the plug does not fit fully into the outlet, reverse the plug. If it still doesn’t fit,  contact a qualified electrician. DO NOT attempt to defeat this safety feature.

  • Before using the humidifier, extend the cord and inspect for any signs of damage; DO NOT use if the cord has been damaged.

  • Keep cord away from heated surfaces and out of the way, where it cannot be stepped on or tripped over.

  • NEVER use in an environment where explosive gases are present.

  • Place humidifier on a stable level surface; DO NOT place on carpet, next to
    heating vents, under direct sunlight, in high-temperature areas, or near computers and electronic equipment.

  • DO NOT place the humidifier directly on wood furniture or other surfaces which could get damaged by water.

  • DO NOT direct the mist against a wall or home appliances.

  • NEVER operate without water in the Tank; DO NOT use anything other than room temperature tap or distilled water.

  • NEVER add essential oils directly to the water, as this will damage the unit and void the warranty.

  • DO NOT touch the water in the Base during operation.

  • DO NOT expose or immerse the Base in water when cleaning.

  • DO NOT pour water into the base through the Air Outlet during cleaning and filling.

  • NEVER block the Air Outlet or intake or cover the unit when it’s in operation.

  • DO NOT use any attachments not provided with the unit.

  • Discontinue use if the humidifier makes loud noises or has a strange smell.

  • DO NOT attempt to repair or adjust the unit; servicing must be performed by professional or qualified personnel.

CAUTION

  • Only operate when fully assembled; only use as intended and described in this manual.
  • Keep out of reach of small children.
  • Always insert plug securely into the power source.
  • Unplug the unit and empty the Water Tank and Base before carrying/moving.
  • Only unplug when the humidifier is turned off; ensure hands are dry.
  • Always turn off the unit before removing, emptying, or filling the Water Tank.
  • Perform regular maintenance of the Ultrasonic Nebulizer; NEVER scrape Nebulizer with a hard or sharp object.
  • Dry the unit completely before storage; store in a cool, dry place.
  • Do not drop, hit, or otherwise subject this product to excessive shock.

No More Dry Air
Thank you for choosing the Air Innovations® – Clean Mist™  Ultrasonic Humidifier with Aroma Tray and congratulations on taking this important step in improving the quality of air in your home or office. The Air Innovations® – Clean Mist™ Ultrasonic Humidifier with Aroma Tray uses Ultrasonic Technology to create humidity instantaneously while working silently to erase the discomforts of dry air.
Unpacking

  1. Carefully remove the humidifier from the box by pulling the Base of the unit (Do not take the unit out of the box by pulling the tank).
    AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
1

  2. Remove the plastic bag from the humidifier.
    AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
2

  3. Remove the Dual Directional Mist Nozzle from the bottom of the packaging.
    AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
3*Follow directions to fill and operate the humidifier.

Specifications

Product Model| Power Consumption| Current| Rating Voltage| Tank Capacity| Dimensions| Weight
---|---|---|---|---|---|---
MH-603| 30W| 0.4A| 110-120V~60Hz| 5.9L / 1.6
Gallons| L10.6” X W7.6”
X H14.5”| 3.7 Lbs.

Parts & Contents

AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
4

 1. Dual Directional Mist Nozzle  8. Water Sensor
 2. Handle  9. Water Reservoir
 3. Water Tank  10. Cleaning Brush
 4. Base  11.  Ceramic Filter
 5. Power/Mist Control Knob  12. Tank Cap
 6. Ultrasonic Nebulizer  13.  Bottom Tank Handle
 7. Air Outlet 14. Aroma Tray

15. Aroma Pads

Filling The Water Tank

WARNING: Always unplug the unit before removing the Water Tank.
WARNING: DO NOT touch the water in the Base.
WARNING: NEVER fill the Water Tank from the top of the unit. Follow Water Tank filling instructions in #4.

AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
5| AIR INNOVATIONS
Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
6
---|---
Remove Dual Directional Mist Nozzle prior to filling the Water Tank.| Lift the Handle on top of the Water Tank to remove the humidifier from the Base.
AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
7| AIR INNOVATIONS
Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
8
Make sure the Handle is snapped back into place, then turn the Water Tank upside down and remove the Tank Cap by turning it counterclockwise.| Filling the Water Tank: Use clean, cool, tap water. WARNING: DO  NOT use extremely cold water, since it may temporarily reduce the mist output. WARNING: NEVER fill with hot/warm water or use additives as this could damage the unit and void the warranty. WARNING: WARNING: If you have hard tap water use our Humidifier Demineralization Filters (available at www.Air- Innovations.com) or use ONLY filtered/distilled water.
AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
9| AIR INNOVATIONS
Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
10
Replace the Tank Cap by firmly turning clockwise until tight. Turn the  Water Tank upright and check the Tank Cap for leaks. If any water drips,  remove the Tank Cap and retighten. WARNING: DO NOT place Water  Tank on the humidifier Base if the cap is leaking.| Lift the Handle up and replace it on the humidifier Base, make sure to follow the shape of the Water Tank and the humidifier Base so that the tank sits level and is flush to the Base. Ensure the tank is firmly seated.

AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
11

Attach the Dual Directional Mist Nozzle to the top of the Water Tank. To easily control the direction of the mist simply position the Dual Directional Mist Nozzle to the  desired direction as pictured to the left.

Operating Instructions

WARNING: DO NOT operate the humidifier without water in the tank.
WARNING: NEVER lift the tank off the Base while the unit is operating.

  1. ON/OFF – Plug into a standard (120V AC) electrical outlet. Turn the Mist Control Knob clockwise until you hear a click and the “Humidity / Waterless” Indicator turns green. To turn OFF, turn the Mist Control Knob counterclockwise until you hear a click and the indicator turns OFF. Mist may not appear immediately; allow up to 15  minutes for the water in the tank to transfer to the Base.AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - figure 12

  2. Mist Output – The unit will turn ON with the lowest mist setting. Turn the Mist Control Knob clockwise to increase the mist output and turn the Mist Control Knob counterclockwise to decrease.
    AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
13

  3. Dual Directional Mist Nozzle – Attach the Dual Directional Mist Nozzle to the top of the Water Tank and position the Nozzle in the desired direction. AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - figure 14

  4. Low Water – When the tank is out of the water the “Humidity / Waterless” Indicator will turn from green to red and the automatic safety shut-off will turn the Ultrasonic  Nebulizer OFF. You may hear the fan for a few minutes, this is normal.
    AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
15

  5. Aroma Tray – By inserting an Air Innovations Essential Oil Aroma Pad into the built-in Aroma Tray, you can transform your humidifier into an easy-to-use fragrance dispenser. AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - figure 16

Visitwww.Air-Innovations.com  to purchase additional Aroma Pads.

Weekly Cleaning & Care

WARNING: Before cleaning always turn the power off and unplug the unit from the outlet.
WARNING: DO NOT rinse Base under the faucet. To clean, wipe the Base with a soft cloth.
WARNING: DO NOT use any solvents or aggressive cleaning agents. Keep water away from the Air Outlet.
WARNING: DO NOT tamper with the Water Sensor.

About White Dust -Use of high-mineral content water may cause a white mineral residue to accumulate on room surfaces near the humidifier. The mineral residue is commonly referred to as “White Dust”. The higher the mineral content (the harder your water is), the greater the potential for White Dust. The White Dust is not caused by a defect in the humidifier but is due only to minerals suspended in the water from your tap. WARNING: If you have hard tap water STOP using tap water and visit our website (www.Air- Innovations.com) to purchase our Humidifier Demineralization Filters or use ONLY filtered or distilled water.

Tank Cleaning – Remove the Mist Nozzle from the top of the Water Tank then remove the Water Tank from the unit. Turn the tank upside down, unscrew the Tank Cap and drain any water from the tank. Wipe the tank with a soft damp cloth then rinse it with warm water inside and out.
Base Cleaning – Gently wipe the Base with a soft damp cloth.

White Dust Cleaning – If mineral deposits “White Dust” are evident around the Ultrasonic Nebulizer a and Water Sensor, clean these surfaces with a soft cloth and a small amount of undiluted white vinegar. If necessary, mix a solution of 50% white vinegar and 50% water and fill the Base with enough solution to cover the Ultrasonic Nebulizer a.  Allow it to soak for an hour, and then use the provided brush to gently loosen build upon the Ultrasonic Nebulizer b. Put 1 cup of water in the Base and wipe clean with a soft cloth.
WARNING: DO NOT rinse Base under the faucet.
Ceramic Water Filter Cleaning – Remove the Water Tank from the humidifier base. Remove the Tank Cap c and rinse Ceramic Filter thoroughly with tap water d , then replace on Water Tank. AIR INNOVATIONS Clean Mist
Ultrasonic Humidifier With Aroma Tray - figure 17

Surface Cleaning – Clean all surfaces of the unit with a clean damp soft cloth.
WARNING: When emptying the Water Reservoir on the Base, make sure that the water is poured away from the Air Outlet e. If water is poured into the outlet it may damage the humidifier.AIR INNOVATIONS Clean Mist Ultrasonic
Humidifier With Aroma Tray - figure 18

Storage

  1. Follow all cleaning instructions prior to storage.
  2. Dry all parts, including the inside of the Water Tank.
  3. Leave the Tank Cap partially loosened to prolong the life of the cap.
  4. Preferably store in its original box, in a dry place away from high temperatures.
  5. Follow all cleaning instructions after long periods of storage.

Troubleshooting

Problem Solution
Weak or no mist output. The water in the unit is too cold: Replace with cool

but not cold water or set the output to High and wait 10-15 minutes.
The surface of the Ultrasonic Nebulizer is dirty: Clean Ultrasonic Nebulizer. (see pg. 6 “White Dust Cleaning”)
Ultrasonic Nebulizer is not working: See Warranty.
White dust is forming on nearby furniture.| Hard tap water may deposit a certain amount of dust. Visit our website (www.Air-Innovations.com) to purchase Humidifier Demineralization Filters or use distilled water.
Water is leaking.| Water Tank Installation: Make sure the tank is correctly attached. (see pg. 4 “Filling the Water Tank”)
A humidifier is not on a level surface: Place on a level surface.
Ceramic Filter Installation: Turn Fitter Tank Cap clockwise until tight.
Condensation is forming around humidifiers or windows.| The mist output level is too high for room size: Decrease the mist output.
The direction of Dual Directional Mist Nozzle: Change the direction of the nozzle.
Aroma Tray does not close.| Aroma Pad is not seated properly: Remove and reinsert the pad.
Missing parts.| Call us toll-free at: 844-600-1370, Monday thru Friday 8:30 am to 5 pm EST.
Please reference model: MH-603
| Try These Other Great
Products For Your Life!|
---|---|---
Available at: www.ForLifeProducts.com, www .Air-Innovations.com, www.Pursfection.com, www.RejuvenateProducts.com

AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
19AIR
INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray - logo
4AIR INNOVATIONS
Clean Mist Ultrasonic Humidifier With Aroma Tray - figure
20

1-YEAR WARRANTY – MH-603

Air Innovations® Clean Mist™ Ultrasonic Humidifier with Aroma Tray comes with a 1-year manufacturer’s warranty. If this unit should become defective within 1-year from  the date of purchase, or if you have any questions or comments regarding replacements for any of our products, please contact us directly at:

Call us toll-free at 844-600-1370
Monday thru Friday 8:30 AM to 5:00 PM EST.
Visit us on the web at: www.Air-Innovations.com
e-mail us: sales@air-innovations.com
Or write us:
Air Innovations
Att: Quality Assurance Dept.
2301 SW 145th Ave.
Miramar, FL. 33027 USA
Please fill out the warranty card and
mail back to the above address.
Or, register your warranty online today.
Simply go to:
www.Air-Innovations.com

Please check here if you would not like to receive any solicitations from our company

THIS UNIT COMES WITH A 1-YEAR WARRANTY SUBJECT TO THE FOLLOWING CONDITIONS:
In the first year, all repairs will be performed free of charge or the unit will be replaced. This warranty is not transferable, it is valid only for the original purchaser. This warranty will be voided if the unit is subjected to unauthorized repair or impact damage. If you have any questions please call toll-free: 844-600-1370. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma
Tray Available In Additional ColorsAIR INNOVATIONS Clean Mist Ultrasonic
Humidifier With Aroma Tray - figure 21

Documents / Resources

| AIR INNOVATIONS Clean Mist Ultrasonic Humidifier With Aroma Tray [pdf] Instruction Manual
Clean Mist Ultrasonic Humidifier With Aroma Tray
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

AIR INNOVATIONS User Manuals

Related Manuals