DJO AirSelect Standard User Guide
- June 7, 2024
- DJO
Table of Contents




BEFORE USING THE DEVICE, PLEASE READ THE FOLLOWING INSTRUCTIONS COMPLETELY AND CAREFULLY. CORRECT APPLICATION IS VITAL TO THE PROPER FUNCTIONING OF THE DEVICE.
INTENDED USE / INDICATIONS:
The STANDARD walking brace provides compressed air support for stable fracture of foot and/or ankle, severe ankle sprains, and post-operative use. Effective in fracture healing and the management of edema (swelling).
PERFORMANCE CHARACTERISTICS:
- Soft-good/ semi-rigid designed to restrict motion through elastic or semi-rigid construction.
- Providing immobilization or controlled movement of the limb or body segment.
- Providing mild protection of a limb or body segment for acute and prophylactic care.
WARNINGS AND PRECAUTIONS:
- Do not over-inflate air cells.
- Improper Aircell inflation may cause significant skin irritation, especially in people with diabetic neuropathy (a diabetic nerve condition).
- Check your skin frequently for “hot spots” and skin irritation.
- If you see any skin changes or feelings of discomfort, reduce the Aircell compression.
- Do not use this device if you cannot feel sensations whether due to post-op anesthesia, nerve, skin or other conditions.
- Use caution when walking on slippery or wet surfaces to avoid injury.
- If there is a feeling of excessive pressure or discomfort while using the device adjust the pressure of the air cells (if equipped)/straps on the device.
- Do not use over open wounds.
- If pain, swelling, changes in sensation or other unusual reactions occur while using this product, you should contact your doctor immediately.
- Do not use the device if it is damaged.
NOTE: Contact manufacturer and the competent authority in case of a serious incident arising due to usage of this device.
APPLICATION INFORMATION:
A cotton or cast sock will enhance comfort – NOT INCLUDED
1) PREPARE BRACE –
- Unfasten straps, remove the front panel, and open the liner.
2) APPLY BRACE –
- While seated, place foot in brace positioning the heel against the back of the brace. Wrap liner around foot and then leg (Fig. A).
- Replace front panel: Position front panel so the Aircast logo is over the toes and the upper part of the panel is secured to the liner (Fig. B).
- Secure straps from bottom to top (Fig. C). Tighten until snug and comfortable.
3) ADJUST AIRCELL COMPRESSION –
The STANDARD walking brace air cells are initially deflated
- Begin inflation on the injured side first. Turn the SELECTOR found on the right side of the brace to the appropriate number (Fig. D). Number 1 inflates the Aircell on the right side and Number 2 inflates the Aircell on the left side. The “lock” position should be used once both air cells are inflated. This prevents accidental deflation.
- To inflate Aircell, place finger over the small hole on top of large inflation pump found on the top right side of brace (Fig E). Pump until Aircell feels snug.
- To inflate other Aircell, rotate SELECTOR to the appropriate number and then press and release a large inflation pump. Pump until Aircell feels snug. When both air cells are inflated, rotate SELECTOR to “lock” position.
- In the event of over-inflation, deflate air cells.
4) DEFLATE AIRCELLS –
- To deflate air cells, turn the SELECTOR found on the right side of the brace to the proper Aircell number (Fig. D).
- Press and hold finger on small release button found on the top right-side of brace (Fig. F).
- Deflate until pressure is comfortable.
NOTE: Deflate air cells before removing brace for proper fit when
reapplying.
NOTE: Higher pressure provides more support when walking, lower pressure
is more comfortable when sitting or reclining. Pressure can also be adjusted
by tightening or loosening straps.
NOTE: The shell can be trimmed with a cast saw or cast scissors to
accommodate larger calves.
CLEANING INSTRUCTIONS:
THE FOAM LINER MAY BE HAND-WASHED IN 86°F/30°C WATER WITH MILD DETERGENT
AND AIR-DRIED. DO NOT PUT IN A DRYER OR USE ANOTHER HEAT SOURCE TO DRY.
HIGH ALTITUDE:
AT HIGH ALTITUDES THE AIRCELLS WILL EXPAND BEYOND THEIR OPTIMAL LEVEL. ADJUST AIRCELL PRESSURE BY TIGHTENING OR LOOSENING THE STRAPS.
WARRANTY:
DJO Global, LLC will repair or replace all or part of the unit and its
accessories for material or workmanship defects for a period of six months
from the date of sale.
NOT MADE WITH NATURAL RUBBER LATEX.
MATERIAL COMPONENTS
Shell: POLYPROPYLENE
Front Panel: HIGH-DENSITY POLYETHYLENE
Straps: NYLON
Inflation Pumps: THERMOPLASTIC POLYURETHANE
Liner: NYLON/POLYURETHANE/POLYESTER (OUTER/FOAM/INNER MESH)
Binding: POLYESTER
Outer Sole / Insole : EVA/RUBBER
Selector dial: NYLON
NOTICE: WHILE EVERY EFFORT HAS BEEN MADE IN STATE-OF-THE-ART TECHNIQUES TO OBTAIN THE MAXIMUM COMPATIBILITY OF FUNCTION, STRENGTH, DURABILITY, AND COMFORT, THERE IS NO GUARANTEE THAT INJURY WILL BE PREVENTED THROUGH THE USE OF THIS PRODUCT.
![]()
MDSS GmbH
Schiffgraben 41
30175 Hannover, Germany
DJO, LLC
1430 Decision Street
Vista, CA 92081-8553 • the USA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>