ENFORCER SM-200Q/W Screw-Terminal Surface-Mount Contacts
- Surface-mount magnetic contacts
- Screw mount using side tabs
- Terminal cover provided (required for all applications)
- ABS plastic case has lip to prevent wires from accidentally touching metal mountings and slotted mounting holes for easier gap adjustment
- Contact reed switch is SPST, deactivated rhodium on gold underplating for a longer expected life
- For closed loop circuits (SM-200Q only)
- For open loop circuits (SM-300Q only)
- 3/4″ (19mm) Gap (SM-200Q only)
- 1/2″ (13mm) Gap (SM-300Q only)
- Lifetime limited warranty
Parts List
- 10x Contact switches
- 10x Terminal covers
- 10x Magnets
- 1x Manual
Specifications
Model | White | SM-200Q/W | SM-300Q/W |
---|---|---|---|
Brown | SM-200Q/BR | SM-300Q/BR | |
Loop type | Closed loop | Open loop | |
Electrical connection | N.O. (SPST) | N.C. (SPST) | |
Operation gap | 3/4” (19mm) | 1/2” (13mm) | |
Connectors | Screw terminals | ||
Material | Case | High-impact ABS plastic | |
Contacts | Deactivated rhodium on gold underplating | ||
Contact rating | 1.0A@10VDC (max.) |
10W (max.)
Operating temperature| -15°~160° F (-25°~70° C)
Switch cycles| 50 Million (0.1mA@5VDC)
Dimensions| Switch| 21/2″x9/16″x1/2″ (63.5x14x13 mm)
Magnet| 21/2″x1/2″x1/2″ (63.5x13x13 mm)
Magnet type| Ferrite
Overview
Protected side of the door/window.
Installation
Please read the manual carefully before you begin the installation.
- Mount the contact above the door or window on the frame. For doors, ensure that the mounting is farthest from the hinged side of the door.
- Connect the two wires to the alarm control panel.
- Mount the magnet on the door/window so that it will face the contact. Be sure that the gap between the contact and magnet does not exceed 3/4″ (19mm) for the SM-200Q or 1/2″ (13mm) for the SM-300Q.
California Proposition 65 Warning: These products may contain chemicals which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov
LIMITED LIFETIME WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for the lifetime of the product. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. Under no circumstances will SECO-LARM be responsible for any costs or charges for removal, installation, or reinstallation. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO- LARM, and the purchaser’s exclusive remedy, shall be limited to repair or replacement only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else. This lifetime limited warranty is for products sold and installed in the United States and Canada. For all other countries the warranty is 1 (one) year.
NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2021 SECO-LARM U.S.A., Inc. All rights reserved.
Website: www.seco-larm.com Email: sales@seco- larm.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>