lowes IRT217 Digital Infrared Digital Thermometer User Manual
- June 7, 2024
- lowes
Table of Contents
lowes IRT217 Digital Infrared Digital Thermometer User Manual
INTRODUCTION
Thank you for purchasing General Tools & Instruments’ (General’s) IRT217 Infrared Thermometer (IRT). The instrument uses an IR sensor to measure the temperature of a surface or object from a distance by quantifying its thermal radiation. This non contact measurement capability allows you to safely determine the temperature of very hot or cold surfaces, hard-to-reach or moving objects, and toxic substances. A red laser with a targeting ring precisely outlines the area being measured. Readings, in °F or °C, are displayed on a liquid-crystal display (LCD).
The IRT217 has:
- A 10:1 distance-to-spot (D:S) ratio
- A high-visibility, 4-digit white-on-black backlit LCD
- A measurement range of -4° to 689°F (-20° to 365°C)
- Automatic reading hold
- A 7-second Auto Power Off (APO) function
WHAT’S IN THE PACKAGE
The IRT217 comes on a blister-packed card along with two “AAA” Alkaline batteries.
PRODUCT OVERVIEW
Fig. 1 shows the key components of the IRT217. Fig. 2 shows all possible
display icons and indications. Use Fig. 1 to familiarize yourself with the
position and function of all components before moving on to the safety, setup
and operating instructions.
Fig. 1. The IRT217’s key components
- A. Laser pointer exit
- B. Infrared sensor
- C. Measurement trigger
- D. Battery compartment
- E. Backlit 4-digit white-on-black LCD
- F. button. Turns laser pointer on and off
- G. °C/°F button. Toggles between measurement units
Fig. 2. All possible display indications
- A. Low battery charge indicator
- B. Laser pointer “on” icon
- C. Temperature readout
- D. Indicates that temperature readouts are in °F
- E. Indicates that temperature readouts are in °C
- F. Indicates operation in scan mode
- G. Indicates last reading is being held
SAFETY INSTRUCTIONS
WARNING!
- Do Not Use For Human Body Temperature
CAUTION!
- The IRT217’s Class 3R laser pointer emits less than 3mW of radiation at 630 to 660nm (nanometers). However, avoid looking directly at the laser, and never point it at people or animals. Eye protection is normally afforded by the blink refl ex.
- Never allow children to operate the instrument.
- Do not operate the IRT217 in explosive environments containing flammable liquids, gases or dust. Doing so may create sparks that can ignite the dust or fumes.
- Keep the IRT away from cardiac pacemakers. A magnet inside the instrument generates an electromagnetic field that can impair their function. Likewise keep the tool away from magnetic data storage media, whose contents may be erased by the magnetic field.
SETUP INSTRUCTIONS
INSTALL BATTERIES
The IRT217 is ready to use after you install two “AAA” batteries.
To open the battery compartment (Fig. 1, Callout D), place the tips of your
thumb and index finger in the cutouts on the sides of the compartment cover
and pull to swing it down. Install the batteries in series according to the
polarity marks on the inside of the compartment. Then swing the cover up and
snap it shut.
OPERATING INSTRUCTIONS
To make a temperature measurement, begin by squeezing the IRT’s trigger (Fig.
1, Callout C) to activate its laser pointer. The display will come to life by
showing a temperature reading, as well as the flashing word SCAN (Fig. 2,
Callout F). Note that the reading changes as you change the target with the
trigger squeezed.
Next, while continuing to squeeze the trigger, choose your target area—the
area whose temperature you wish to measure—and aim the gun at it. Move closer
to or further from the target so the visible targeting ring produced by the
IRT exactly covers the target area. Be sure the ring does not extend beyond
the target area—in which case the measurement might include hotter or colder
surfaces outside its perimeter, producing an erroneous reading.
Once you’ve defined the target area, release the trigger. Doing so changes
SCAN to HOLD (Fig. 2, Callout G) and “freezes” the readout at the temperature
of the target for seven seconds.
After seven seconds, the IRT217 (including the laser pointer) automatically
powers off to extend battery life. The seven-second hold enables you to take
the temperature of surfaces you cannot see (under or behind objects, for
example) and then read the display after returning the gun to eye level.
To change the measurement unit from Celsius to Fahrenheit, press the ºC/ºF
button (Fig. 1, Callout G.). To turn off the laser pointer, press the button
(Fig. 1, Callout F).
OPERATING/MAINTENANCE TIPS
- The display indicates OH if the temperature of a target is above 689°F (365°C), and OL— if its temperature is below -4°F (-20°C).
- While making measurements, the brightness of the laser and the display back light will gradually decrease along with battery charge. This will not affect the accuracy of measurements.
- When the batteries become critically short of power, the icon will automatically appear on the screen. When it does, replace both batteries.
- The IRT217 may not be able to measure the temperature of computer/TV monitors because they absorb IR radiation. Similarly, attempting to measure the temperature of a target behind glass, plastic or steam may produce erroneous results.
- To avoid having old or unused batteries leak acid and ruin the instrument, remove both batteries when you do not expect to use the IRT217 for a long period of time (several months, for example).
- Clean the lens of the infrared sensor lens (Fig. 1, Callout B) often with compressed air or a moist cotton cloth. Never use a solvent or an abrasive cleaner. To clean the housing, use a soft, damp cloth.
- Abrupt temperature changes will cause condensation and possible vapor penetration. Clean the LCD after the vapor evaporates.
- Keep the IRT217 away from water, extreme temperatures, corrosive gases and strong electromagnetic fields (such as produced by arc welders and induction heaters).
SPECIFICATIONS
- Distance-to-spot (D:S) ratio: 10:1
- Measurement range: -4° to 689°F (-20° to 365°C)
- Measurement accuracy: ±3.6°F (2°C) or ±2% of reading above 32°F (0°C) ±5.4°F (3°C) or ±2% of reading below 32°F (0°C)
- Response time: 500 milliseconds for 95% response
- Emissivity: Fixed at 0.95
- Display resolution: ±0.1° (F or C)
- Laser wavelength: 630 to 660nm
- Laser class: 3R (<3 mW)
- Auto power off trigger: No activity for seven seconds
- Power source: Two “AAA” batteries (included)
- Operating temperature (ambient): 32° to 104°F (0° to 40°C)
- Product dimensions: 5.9 x 2.9 x 1.3 in. (150 × 73 ×32mm)
- Product weight: ~2.5 oz. (70g), without batteries
WARRANTY INFORMATION
General Tools & Instruments (General) warrants its instruments and accessories, and digital tools products against defects in material or workmanship for one year from the date of purchase unless otherwise stated on the packaging, user’s manual, and/or marketing materials.
This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the product. It also does not cover products purchased from unauthorized distributors. A proof of purchase must accompany each warranty claim.
Any implied warranties arising from the sale of a General product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. General shall not be liable for loss of use of the product or other incidental or consequential damages, expenses, or economic loss, or for any claim of such damage, expenses, or economic loss. State laws vary. The above limitations or exclusions may not apply to you.
For more details or to file a warranty claim, contact General Tools & Instruments Technical Support at techsupport@generatools.com.
RETURN FOR REPAIR POLICY
Every effort has been made to provide you with a reliable product of superior quality. However, in the event your instrument requires repair, please contact our Customer Service to obtain an RGA (Return Goods Authorization) number before forwarding the unit via prepaid freight to the attention of our Service Center at this address:
General Tools & Instruments
75 Seaview Drive
Secaucus, NJ 07094
212-431-6100
(800) 697-8665
e-mail: sales@generaltools.com
IRT217 User’s Manual 10/22/20
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>