BRISTAN FZ SHXMMCTFF Frenzy Cool Touch Bar Mixer User Guide

June 7, 2024
BRISTAN

FZ SHXMMCTFF Frenzy Cool Touch Bar Mixer

Specifications

  • Product Codes: FZ SHXMMCTFF C (D2), FZ
    SHXVOCTFF C (D2)

  • Inlet Water Temperature: Cold Water Supply:
    2.0-4.0 bar, Hot Water Supply: 1.0-5.0 bar

  • Inlet Dimensions: 150mm Centres

  • Working Pressures: Min: 0.2 bar, Max: 5.0 bar,
    Maximum Static Pressure: 10.0 bar

  • Tools You’ll Need: Pencil, Flat head
    Screwdriver, Drill, Cross head Screwdriver, Spanner, Pipe Cutter,
    Hexagonal Keys, Socket Spanner

Installation Instructions

  1. Identify the required position of the valve and prepare the
    water supply pipes. Supply pipes should be 150mm apart.

  2. Using the backplate supplied with the wall mount, mark and
    drill holes.

  3. Secure the rubber backplate and backplate into place.

  4. Secure the isolator onto the backplate ensuring the olive is
    positioned over the pipework correctly.

  5. Push shrouds to the back of the wall outlet, securing them
    against the rubber fixing plate.

  6. Insert filter washer and secure the shower to the wall
    mount.

  7. Remove the concealing cap from the shroud.

Operation

Temperature Setting:

  1. Turn the shower on, letting the temperature stabilize.

  2. Rotate the shroud until the opening aligns with the isolation
    screw.

  3. Turn the screw to isolate the water. Reverse the process when
    turning the water back on.

Cold: Rotate the shroud until the opening
aligns with the isolation screw.

Hot: Push the temperature control button down
and turn handle towards you to increase.

Off: Remove the cap, screw, and…

FAQ

Q: What should I do before installing the product?

A: Before installing this product, ensure that
the water supply is thoroughly flushed to remove any debris. Also,
check for hidden electrical wires or water supply pipes before
drilling into walls.

Q: What are the working pressures for cold and hot water

supplies?

A: The cold water supply should be within
2.0-4.0 bar, and the hot water supply should be within 1.0-5.0
bar.

Q: What tools are required for installation?

A: You will need a pencil, flat head
screwdriver, drill, cross head screwdriver, spanner, pipe cutter,
hexagonal keys, and socket spanner.

Installation Instructions & User Guide

Specifications
Working Pressures

Please leave these instructions with the end user

Product Codes: FZ SHXMMCTFF C (D2) FZ SHXVOCTFF C (D2)

Inlet Water Temperature

Inlet Dimensions

Cold Water Supply

Hot Water Supply

150mm Centres

Min: 0.2 bar

Max: 5.0 bar

2.0 3.0

1.0

4.0

0.2

5.0

Pressure BAR

2.0 3.0

1.0

4.0

0.2

5.0

Pressure BAR

Maximum Static Pressure: 10.0 bar

Tools You’ll Need

25°C 5°C

65°C 60°C

Min: 5°C Max: 25°C 60-65°C Recommended

Factory pre-set 38°C

IMPORTANT
The inlet hot water must be at least 10°C above the required blend temperature.

Inlet Connections
15mm Compression TMV2 Designation
HP-S & LP-SE

Pencil

Flat head Screwdriver

Drill

Cross head Screwdriver

Spanner

Pipe Cutter

Hexagonal Keys

Socket Spanner

Prior to Installation

Pack Contents

All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated and receive regular maintenance in accordance with these instructions.
This product needs to be installed in accordance with, and meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and current by-laws. For full Installation Requirements & Notes (IRN) please visit wras.co.uk/directory.

x2 x2
x1

Supplied with
FZ SHXMMCTFF C only
x1
x1

Isolation valves must be fitted to the inlet water supplies to ensure ease of future

maintenance.

x1

Before installing this product the water supply must be thoroughly flushed in order to remove any swarf, solder etc.

This product must not be modified in any way as this will invalidate the

guarantee.

x1

Full access must be made available for future maintenance/servicing purposes.

Before drilling into walls, check that there are no hidden electrical wires, cables or water supply pipes. This can be checked with the aid of an electronic detector.
If power tools are used do not forget to: – Wear eye protection – Unplug equipment after use
If in doubt, contact a registered plumber or your Local Water Authority or the Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing, 64 Station Lane, Hornchurch, Essex, RM12 6NB, Tel: 01708 472791

x2

x2

x2 x2

x2 x2

x1

x2

x8

x8

Installation
1
Identify the required position of the valve and prepare the water supply pipes. Supply pipes should be 150mm apart.
Using the backplate supplied with the wallmount, mark and drill holes.
3

2

150mm Centres

4

21mm

Secure the rubber backplate and backplate into place.
5

hocRotElodMnEotnMheBthEleeRft, right

Secure the isolator onto the backplate ensuring the olive is positioned over the pipework correctly.
Isolation
1

Push shrouds to the back of the wall outlet, securing them against the rubber fixing plate
2

RTEoMsEerMvBicEeR your
product!

Insert filter washer and secure the shower to
the wall mount.

Remove the concealing cap from the shroud.
Operation

IMPORTANT

Please refer to the

TMV booklet for

commissioning

and testing

guidance.

On

Cold

Rotate the shroud until the opening aligns with
the isolation screw.
Turn the screw to isolate the water. Reverse the process when turning the water back on.

To override the 38°

pre-set temperature,

Hot

push the

temperature control

button down and

turn handle towards

you to increase.

Off

Temperature Setting

3

1

2

Turn the shower on, letting the temperature stabilise.

Remove the cap, screw and
temperature handle.

Maintenance – Cartridge Cleaning

1

2

Unscrew the flow valve.

Turn cartridge spindle
clockwise to decrease the temperature. Turn cartridge
spindle anti-clockwise to increase the temperature.
3

4 12
Reverse steps 1-2 to reinstall the cartridge
and handle.
Remove adaptor, nut and cartridge.

Riser Installation (not supplied with FZ SHXVOCTFF C)

1

2

3

Assemble the riser, attaching the hose retainer, slider and both
the top and bottom brackets.

Use the assembled
riser to mark the desired position for the riser on the wall.

4

Slide top bracket onto

5

riser and

secure to wall.

Drill the marked holes.

Insert riser rail into lower bracket and secure to the
wall.

6

Slide hose through
hose retainer before
attaching the handset to the shower.

Remove temperature and flow handle.

4

Remove O-rings and soak all
components in

5

de-scaler and wash off

in clean water. Examine

all seals and replace if

needed.

Use WRAS

approved silicon based

grease on all seals.

6
Replace cartridge and turn spindle anti-clockwise to maximum temperature.

Replace nut and adaptor. Ensure the raised side is facing towards the back of
the valve.

7

8

Slide handle onto adaptor
and turn clockwise until you meet

9

12

resistance.

Turn cartridge spindle clockwise to decrease the temperature. Turn
cartridge spindle anti-clockwise to increase the temperature.
Servicing Intervals

RTEoMsEerMvBicEeR your

Spare Parts

product!

Reverse steps 1-2 to reinstall the valve and
secure handles.

To reduce the build up of limescale and to ensure this shower works to its maximum performance we recommend this shower is serviced every 6-12 months depending on the hardness of your water.

To replace any spare parts for your shower why not scan the below QR Code and search for your product.

Troubleshooting

Symptom
No flow or low flow rate
Water dripping from shower

Cause
Partially closed isolation valve.
Instantaneous water heater cycles on and off as flow rate or pressure is too low.
Head of water is below the minimum distance required.
Hot or cold water being drawn off elsewhere causing pressure changes or instantaneous
boiler temperature changes.
Airlock or partial blockage in the supply pipework.
This is normal for a short time after using the shower.
If water continues to drip, possibly due to the cartridge

Remedy Open isolation valve. Increase water flow rate or pressure through system.
2 meters minimum required.
Do not use other water outlets when using the taps.
Flush through pipework to ensure removal of debris and any airlocks.
This is caused by residual water tension, the build up of water in the shower.
Remove cartridge and clean, refer to ‘Maintenance’ section before starting any maintenance.

Shower does not turn on

Closed isolation valve. Mains water supply turned off.

Open isolation valve. Turn on mains water supply.

At Bristan, we want to make things as easy as possible for our customers. That’s why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind. To start your free guarantee simply scan the QR code and register your product. Alternatively visit www.bristan.com/register. For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice. For full guarantee terms and conditions visit www.bristan.com/guarantees.