Rubicson Wireless Rain Gauge User Manual
- June 6, 2024
- rubicson
Table of Contents
manual
Wireless rain gauge
Art no: 49109
Main functions
- The current Outdoor Temperature Arrow icon indicates the direction temperature is trending.
Rising>1°C/2°F(5%RH)
| Steady><1°C/2°F(5%RH)|
Falling<1°C/2°F(5%RH)
---|---|---
| |
2. Rain Gauge Low Battery Indicator
3. Rain Gauge Signal Strength
4. Rain Alarm Icon Indicates the alarm is set
5. The current Indoor Temperature Arrow icon indicates the direction temperature is trending.
Rising>1°C/2°F(5%RH)
| Steady><1°C/2°F(5%RH)|
Falling<1°C/2°F(5%RH)
---|---|---
| |
6. Display Low Battery Indicator for RF sensor
7. Barometric Pressure Trend Indicator Arrow icon indicates direction pressure is Subtle variations in barometric pressure greatly affect the weather. This rain gauge station displays the current barometric pressure trend with an arrow icon to indicate the direction the pressure is trending (falling, steady or rising).
Rising>0.03HPA
| Steady><0.03HPA|
Falling<0.03HPA
---|---|---
| |
8. Storm Alert Indicator STORM! Activates when a storm is approaching. When the pressure is trending higher than 6HPA then STORM! will be displayed.
9. History BUTTON Access rainfall records (yesterday, this week, this month this year, last year, all-time) and all-time records for temperature and humidity.
10. Clock (hour, minutes), Date, Month display
Displayed units of temperature: °C/°F, Default is °C
-
DST TIME ON/OFF
-
Current Indoor Humidity Arrow icon indicates direction humidity is trending.
-
Today’s Rain Indicator Illustrates rainfall collection up to 1 inch (25 mm).
-
Rainfall Total For current mode selected.
-
Dew Point Displays dew point calculation when the temperature is 80°F (27°C) or below.
-
Heat Index Displays heat index calculation when the temperature is 80°F (27°C) or above.
-
Current Outdoor Humidity Arrow icon indicates direction humidity is trending.
-
Wireless Sensor Signal Strength
-
Sensor Low Battery Indicator
-
Backlight function
Specification
Temperature range | Outdoor: -40°C to 60°C |
---|
Indoor : 0°C to 50°C
Humidity range| 25-90%
Rainfall measurement| 0.01 inches (0.25mm) and up
Wireless range| Wireless sensor: 50M
| Rain gauge: 50M
Power| Base station : 3 x AAA or 230V-adapter
Sensor : 2 x AAA
| Rain gauge: 2*AA
Data reporting| Wireless sensor: 57-second updates
Indoor: 30-second updates
Rain gauge: 85-second updates
Frequency Range| 433.050 MHz to 434.790 MHz
Effective Radiated Power| -13.76dBm
Installation
Buttons: “SET’BUTTON, “UP” BUTTON, “DOWN BUTTON, “RECORD” BUTTON Install
battery or plug the AC adapter, then press and hold the “SET” button to enter
the corresponding setting, the setting sequence is: rain alarm
on/off→12/24HR→DST ON/OFF-→hour→minutes→month→date+year→C/F-→rainfall unit
inches/mm+normal display Press button “SET” to confirm the setting or no
operating after 10 seconds back to normal mode.
Set a Daily Rain Alarm
When the rain alarm sounds, the display emits an audible alert and flashes
the rainfall total. The alarm can be customized to notify you when your
programmed value is reached. The alarm automatically resets at 12:00 am-
midnight every day.
- Press and hold the “SET button to enter setup mode. Use the “UP” button or ” DOWN” button until the “ALARM ON” symbol appears on the display.
- Press the “SET” button and use the ” UP ” or ” DOWN ” buttons to adjust the alarm value.
- Press the “SET” button to save your settings. The alarm is now programmed and turned on.
Disable a Rain Alarm
- Press and hold the “SET” button to enter setup mode. Use the ” UP” or ” DOWN” buttons until the “ALARM OFF symbol appears on the display.
- Press the “SET” button to save your settings. The alarm is now turned off.
NOTE: The RAIN ALARM and STORM ALERT are NOT intended to be a safety
device or warning system.
Silencing an alarm
Once the alarm value is met, the alarm will sound for 1 minute, then
silence itself. While the alarm is sounding, you may manually silence the
alarm by pressing any button.
Rainfall Tracking
This rain gauge station features enhanced tracking of historical rainfall
data. The rain indicator illustrates today’s rain collection up to 1 inch (25
mm).
Press the RECORD button to review historical rainfall records.
Records are shown in the following order:
PREVIOUS DAY TOTAL- CURRENT WEEK TOTAL-MONTHLY TOTALS FOR CURRENT YEAR-CURRENT
YEAR TOTAL -PREVIOUS YEAR TOTAL
*Will only show months that measured rainfall.
RAINFALL HISTORY
|
---|---
All-Time High & Low Records
All-time high and low records are displayed for the indoor and outdoor
temperature and humidity with a timestamp for when the record was set.
View all-time high and low records for temperature and humidity by pressing
the “RECORD” button on the front of the display until temperature and humidity
records are shown.
To manually clear all-time LOW recorded values, press and hold the “DOWN”
button located on the back of the display for 2 seconds while viewing the
record you wish to clear.
To manually clear all-time HIGH recorded values, press and hold the “UP”
button located on the back of the display for 2 seconds while viewing the
record you wish to clear.
Daily High & Low Records
Today’s high and low records are displayed for indoor and outdoor temperature
and humidity. Today’s records automatically clear at 12:00 am-midnight every
day.
View today’s high or low records for temperature and humidity by pressing the
“UP” or “DOWN” buttons located on the back of the display. Press and release
again to cycle through available records.
To manually clear today’s LOW recorded values, press and release the “DOWN”
button located on the back of the display to view low records, then press and
hold the “DOWN” button for 2 seconds while viewing the record you wish to
clear.
To manually clear today’s HIGH recorded values, press and release the “UP”
button located on the back of the display to view high records, then press and
hold the “UP” button for 2 seconds while viewing the record you wish to clear
Input voltage (V) | AC 100-240V |
---|---|
Input AC frequency (Hz) | 50.60Hz |
Output voltage (V) | DC 5.0V |
Output current (A) | 0.3A |
Output power (W) | 1.5W |
Average active efficiency (%) | 74.5% |
No-load power consumption (W) | 0.04W |
Simplified EU Declaration of Conformity
Kjell & Company hereby declares that this device is in compliance with the
essential requirements and other relevant provisions of Directive 2014/53/EU.
Full text of the EU declaration of conformity is available
atwww.kjell.com/49109
Note!
If you encounter any problems with the manual, please go to
www.kjell.com/49109 for an updated version.
wwwsubicson.com
Box 50435, Mahn,
Sweden
2020.11-13