43107
ZW3015
In-Wall
0-10V Smart Dimmer
READ IT OR WATCH IT
Read instructions or watch the easy-to-follow videos. Scan QR code or visit
https://byjasco.com/43107i
Convert any smart control to a multi-location switch
For a list of compatible devices, visit ezzwave.com
To purchase an add-on switch or for more details, visit ezaddonswitch.com.
Each smart control supports up to 4 add-on switches ezaddonswitch.com
Purchase additional items at EZzwave.com or visit your local retailer.
Tools you will need
IMPORTANT!
The dimmer is designed only for use with permanently installed fixtures.
Getting to know your new Z-Wave device
- Turn-ON/OFF and adjust dim levels manually or remotely via the Z-Wave controller
- Can be included in multiple groups and scenes
- May be used in the single-pole installation or with up to four add-on switches (#46561) in 3-way or 4-way wiring configurations
- Auto line/load detection
- Uses a standard toggle wallplate for single-gang installations (wallplate not included)
- Z-Wave certified for simple pairing and integrated home automation
- Screw terminal installation — requires wiring connections for line (hot), load, neutral and ground. Traveler wire required for 3-way or 4-way installation
- This Z-Wave device has advanced features that allow you to customize your experience.
These features can only be adjusted by a Z-Wave-enabled controller that supports the Z-Wave configuration command class. For a complete list of adjustable configurations, visit www.ezzwave.com/config
A. Ground (Green/Bare)
B. Line or Load (Black)
C. Line or Load (Black)
D. Traveler (Red/Other)| E . +/- (Output terminals)
F. Neutral (White)
G. Up — press & release to turn dimmer on, press & hold to increase
brightness
H. Down — press & release to turn dimmer off, press & hold to dim
---|---
|
---|---
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture
at the service panel. All wiring connections must be made with the POWER OFF
to avoid personal
injury and/or damage to the switch. This device is intended for installation
in accordance with the National Electric Code and local regulations in the
United States or the
Canadian Electrical Code and local regulations in Canada. If you are unsure or
uncomfortable about performing this installation, consult a qualified
electrician.
Multi-switch wiring
For 3-way installations, please refer to the add-on switch (46561) manual.
Single-switch wiring
-
Shut off power to the circuit at the circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to the switch box before continuing. -
Remove wallplate.
-
Remove the switch mounting screws.
-
Carefully remove the switch from the switch box. DO NOT disconnect the wires.
-
There are up to six screw terminals on the dimmer; these are marked:
A. GROUND — Green/Bare
B. LINE or LOAD — Black (connected to power or lighting)
C. LINE or LOAD — Black (connected to power or lighting)
D. TRAVELER — Red/Other (only in 3-way installations)
E. +/- output terminals
F. NEUTRAL — White
Match these screw terminals to the wires connected to the existing switch. -
Disconnect the wires from the existing switch. Label wires according to the previous terminal connection.
Observe important wiring information
IMPORTANT! This dimmer is rated for and intended to only be used with copper wire.
Wire gauge requirements
Use 14AWG or larger wires suitable for at least 80° C for supplying line
(hot), load, neutral, ground and traveler connections. The +/- output
terminals require 26-16AWG.
Wire strip length
Attach using the enclosure’s holes, strip insulation 5/8in. (16mm).
UL specifies the tightening torque for the screws is 14Kgf-cm (12lbf-in).
-
Connect the green or bare copper ground wire to the GROUND terminal.
-
Connect the black wire from the light to either LINE/LOAD terminal.
-
Connect the black wire from the electrical service panel (hot) to the other LINE/LOAD terminal.
4. Connect the white wire to the NEUTRAL terminal (use a jumper wire if needed).
NOTE: The traveler terminal is only used for 3-way or 4-way wiring and should remain insulated if the dimmer is being installed in a 2-way system (one dimmer & one load). -
Connect the + wire from the light fixture to the + on the dimmer using a small, flathead screwdriver.
-
Connect the – wire from the light fixture to the – on the dimmer using a small, flathead screwdriver.
-
Insert dimmer into the switch box being careful not to pinch or crush wires.
-
Dimmer must be independently mounted (vertical position only).
-
Secure the dimmer to the box using the supplied screws.
-
Mount the wallplate.
-
Reapply power to the circuit at the fuse box or circuit breaker and test the system.
Basic operation
The connected light can be turned ON/OFF and adjust dim levels in two ways:
- Manually from the front panel of the in-wall dimmer.
- Remotely with a Z-Wave controller.
Manual control
The front panel toggle allows the user to turn ON/OFF the connected fixture.
- To turn the connected fixture ON, press up and release the toggle.
- To turn the connected fixture OFF, press down and release the toggle.
Adjust dim level
- To increase brightness, press up and hold the toggle.
- To decrease brightness, press down and hold the toggle.
Cycle LED light
An LED shines behind the toggle to act as a guiding light or status indicator.
How to cycle between options: Press up three times, then down one time
quickly
- LED is OFF all the time (default)
- LED is ON all of the time (illuminates dimmer in the dark)
- LED is ON when the load is OFF (guide light in the dark)
- LED is ON when the load is ON (indicates the dimmer is ON)
LED bulb adjustments
Not all LED bulbs are made the same, and performance varies between dimmer
brands. This can cause adverse bulb behavior, such as flickering or strobing.
To account for this scenario, this dimmer features adjustable dim and
brightness thresholds to allow setting minimum and maximum levels.
Minimum dim threshold
- Press the OFF button four times, then the ON button once quickly.
- Light starts at the most recent dim level (default — 1%).
- Press the ON or OFF button until the bulb reaches desired brightness without flickering.
- The LED stops flashing 10 seconds after releasing the button to indicate the minimum threshold is set.
Note: This can be set by Z-Wave configuration parameter 30/size: 1 byte/values 1-99 (default — 1)
Maximum brightness threshold
- Press the ON button four times, then the OFF button once quickly.
- Light starts at the most recent brightness (default — 99%)
- Press the ON or OFF button until the bulb reaches desired brightness without flickering.
- The LED stops flashing 10 seconds after releasing the button to indicate the maximum threshold is set.
Note: This can be set by Z-Wave configuration parameter 31/size: 1byte/values 1-99 (default —99)
Adding your device to a Z-Wave network
- Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.
- Once the controller is ready to add your device, press up and release the toggle.
- The controller’s app will indicate if it discovers the switch. If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the side of the box or the QR code label on the product (see Figure 1). Enter the 5-digit code
Please reference the controller’s manual for instructions.
You have complete control to turn your fixture ON/OFF/DIM and create groups,
scenes, schedules, and interactive automation programmed by your controller.
If your Z-Wave certified controller features remote access, you can control
your fixture from your mobile devices.
NOTE: SmartStart enabled products can be added into a Z-Wave network by
scanning the QR code on the product with a controller providing SmartStart
inclusion. No further action is required and the SmartStart product will be
added automatically within 10 minutes of being switched on in the network
vicinity.
To remove and reset the device
-
Follow the instructions for your Z-Wave certified controller to remove a device from the
Z-Wave network. -
Once the controller is ready to remove your device, press up and release the toggle.
To return your dimmer to factory defaults
Quickly press the ON (up) button three times then immediately press the OFF
(down) button three times.
NOTE: This should only be used if your network’s primary controller is
missing or otherwise inoperable.
NOTE: Actual performance of any CFL or LED varies from bulb type to bulb
type and among manufacturers. It is important to note only bulbs designed as
dimmable should be used on a dimmer.
To find out if your bulb is dimmable, please check the package, the bulb
itself, or call the bulb manufacturer directly.
For a complete list of recommended CFL/LED bulbs for this and other Z-Wave
products from Jasco, please visit
www.byjasco.com/z-wave
Add-on switch 46561 is required for multi-switch installations
Connecting the traveler terminal of this dimmer to a standard switch will
cause damage or result in improper function. If this dimmer is a part of a
multi-switch installation, do not connect the traveler wire or apply power
until add-on switches (46561) are correctly installed. For more information on
3-way or 4-way installations, view the manual with the add-on switch.
Z-WAVE
INTEROPERABILITY
This product can be included and operated in any Z-Wave network with other
Z-Wave certified devices from other manufacturers and/or other applications.
All nonbattery-operated nodes within the network will act as repeaters
regardless of vendor to increase the reliability of the network.
This device supports Association Command Class (3 Groups)
- Association Group 1 supports Lifeline, Multi-level Switch report
- Association Group 2 supports Basic Set and is controlled with the local load
- Association Group 3 supports Basic Set and is controlled by double-pressing the ON or OFF button
- Each Association Group supports 5 total nodes
For more details, visit ezzwave.com
DO NOT RETURN THIS PRODUCT TO THE STORE NE RETOURNEZ PAS CE PRODUIT AU MAGASIN NO DEVUELVA ESTE PRODUCTO A LA TIENDA
If you have any problems or questions, contact our U.S.-based Consumer Care at
1-800-654-8483, option 1,
Monday–Friday, 7 AM–8 PM Central Time.
For the most up-to-date product support, accessories, electronic (PDF) format
manuals, and more, visit
www.byjasco.com/support.
- No user-serviceable parts in this unit.
WARNING
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
CONTROLLING APPLIANCES
CAUTION:
- ONLY USE TO CONTROL DIMMABLE CFL/LED BULBS
- DO NOT EXCEED RATINGS
- DO NOT USE TO CONTROL ANY DEVICE WHERE UNINTENDED OPERATION COULD CAUSE UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)
- DO NOT USE TO CONTROL RECEPTACLES
- FOR INDOOR USE ONLY
NOT FOR USE WITH MEDICAL OR LIFE SUPPORT EQUIPMENT
Z-WAVE ENABLED DEVICES SHOULD NEVER BE USED TO SUPPLY POWER TO OR CONTROL THE
ON/OFF STATUS OF MEDICAL OR LIFE SUPPORT
EQUIPMENT.
WARRANTY
Jasco Products Company warrants this product to be free from manufacturing defects for five years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights, and you may also have other rights which vary from state to state. Please contact our U.S.-based Consumer Care at 1-800-654-8483 (option 1) between 7 AM – 8 PM, M-F, Central Time or www.byjasco.com if the unit should prove defective within the warranty period.
Jasco Products Company LLC, Building B
10 E. Memorial Rd. Oklahoma City, OK 73114.
SPECIFICATIONS
ZW3015
Power: 120/277VAC
Signal (frequency): 908.4/916MHz
Maximum loads: “960VA @ 120VAC” and “1385VA @ 277VAC”
Range: Up to 150ft. line of sight between the wireless controller and the
closest Z-Wave receiver module
Operating temperature range: 32-104° F (0-40° C)
Use 14-12AWG wires suitable for at least 80° C
The +/- output terminals require 26-16AWG
For indoor use only
Specifications subject to change without notice due to continuing product
improvement
FCC/IC
This device complies with Part 15 of the FCC and Industry Canada license-
exempt RSS standards.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. Such
modifications could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee interference will not occur in
a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from which the
receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
Important note: To comply with the FCC RF exposure compliance
requirements, no change to the
antenna or the device is permitted. Any change to the antenna or the device
could result in the device exceeding the RF exposure requirements and void the
user’s authority to operate the device.
Responsible Party – US Contact Information
Estados Unidos
FCC — U2ZZW3015
Jasco Products Company | Model: ZW3015/43107
10 E. Memorial Rd., Oklahoma City, OK 73114 |
1-800-654-8483
CAN ICES-3(B)/NMB-3(B)
All brand names shown are trademarks
of their respective owners.
MADE IN CHINA
DISTRIBUTED BY JASCO PRODUCTS COMPANY LLC,
10 E. MEMORIAL RD., OKLAHOMA CITY, OK 73114.
©JASCO 2020, 43107 , ZW3015 ,09/04/20 v1
References
- Add-On Switches
- Z-Wave by Jasco
- Jasco
- Support
- Z-Wave by Jasco
- Z-Wave In-Wall Smart Dimmer 120/277 Installation - 43105 43107 - YouTube
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>