Jasco ZW6307 portable smart Motion sensor User Manual

June 5, 2024
JASCO

ZW6307 portable smart Motion sensor
User Manual

Smart Motion sensor

Jasco ZW6309 smart Flood Freeze sensor - qr code

Read instructions or watch the easy-to-follow video. Scan QR code or visit https://byjasco.com/52247i
Purchase additional items at EZzwave.com or visit your local retailer. Jasco ZW6309 smart Flood Freeze sensor -
fig

HOMEDEPOT MRS-LKEX-66AAK 50-Pint Portable Dehumidifier -
IconDO NOT RETURN THIS PRODUCT TO THE STORE
If you have any problems or questions, contact cur U S.-based Consumer Care at 1-800-654-8483, option 1, 7 AM-8 PM, M-F, CT. For the most up-to-date product support, accessories, electronic (PDF) format manuals, and more, visit www.byjascaco.com/support
• No user-serviceable parts in this unit

WARNING

  • FOR INDOOR USE ONLY
  • BATTERIES MAY LEAK HARMFUL LIQUIDS OR IGNITABLE MATERIALS OR EXPLODE CAUSING INJURY AND PRODUCT DAMAGE
  • DO NOT MIX OLD AND NEW OR OTHER BATTERY TYPES
  • REPLACE ALL BATTERIES AT THE SAME TIME
  • REPLACE EXHAUSTED BATTERIES IMMEDIATELY
  • REMOVE BATTERIES IF THE PRODUCT IS TO BE UNUSED FOR EXTENDED PERIODS
  • DO NOT USE Z-WAVE DEVICES TO CONTROL ELECTRIC HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRFCFNT A HAZARDOUS CONDITION DUE TO UNATTENDED OR UNINTENTIONAL OR AUTOMATIC POWER-ON CONTROL

NOT FOR USE WITH MEDICAL OR LIFE-SUPPORT EQUIPMENT,
Z-WAVE-ENABLED DEVICES SHOULD NEVER BE USED TO SUPPLY POWER TO OR CONTROL THE ON/OFF STATUS OF MEDICAL AND LIFE-SUPPORT EQUIPMENT.
This device supports lifeline and notification (association group 1) supporting 5 nodes. Group 1 must be assigned the node ID of the primary controller where unsolicited notifications will be sent. The Z-Wave controller should set this association automatically after inclusion. Lifeline association only supports the ‘device reset locally” function. Refer to the instructions of your controller for any available details on how this can be set.

WARRANTY

Jasco Products Company warrants this product to be free from manufacturing defects five years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights, and you may also have other rights which vary from state to state. Please contact our U.S.-based Consumer Care at 1-800-654-8483 (option 1) between 7 AM — 8 PM, M-F, CT or www.byjasco.com if the unit should prove defective within the warranty period.

Jasco Products Company LLC, Building B 10 E.
Memorial Rd. Oklahoma City, OK 73114.

SPECIFICATIONS

Power: 2 CR123A batteries (included), USB power option 5V/500mA (not included)
Signal (frequency): 908.4/916MHz
PIR range: Up to 180°
PIR Distance: Up to 45ft.
Z-Wave Range: Up to 150ft. line of sight between the wireless controller and the closest Z-Wave receiver module
Operating temperature range: 32-104° F (0-40° C)
For indoor use, only Specifications are subject to change without notice due to continuing product improvement

Accessories

Jasco ZW6307 portable smart Motion sensor fig
1

To purchase compatible accessories, visit www.byjasco.com/USB

Getting to know your new Z-Wave device

  • Z-Wave certified for simple pairing and integrated home automation
  • Transmits notification to the connected controller when motion is detected
  • Red LED indicates motion activation; blue LED indicates programming changes and status
  • Supports association with up to five devices
  • Easy button-press programming
  • Three sensitivity settings — low, medium, and high
  • The sensor offers an ultra-wide detection angle and extended distance for any size of the room .
  • Wall- and corner-mount options
  • Battery or USB power
  • Advanced configurations

Jasco ZW6307 portable smart Motion sensor fig 6

A. PIR sensor
B LED – blue, red, and purple behind cover
C. Programming button
D Wall-mount insert
E. Micro USB cable opening
F. Battery door screw
G. Wall-mount swivel base -included for optional wall mounting
H. Mounting hardware – anchors and screws
Jasco ZW6307 portable smart Motion sensor fig NOTE: The smart motion sensor has dual power options – it can be powered by batteries (included) or micro USB (adapter and cable sold separately). When Inclusion is powered by batteries, the signal repeater function is disabled to conserve battery power. When inclusion is powered by micro USB, the signal repeater function is active and extends your Z-Wave network.
For battery power:

  1. Unscrew the battery door screw and remove the door.
  2. Hold batteries in place and remove plastic tabs to activate the sensor,
  3. Replace the battery door and secure the screw.

NOTE: When replacing batteries, ensure both CR123A batteries (included) are installed correctly noting proper polarity.
For micro USB power:

  1. Unscrew the battery door screw and remove the door.
  2. Remove the batteries and locate the micro USB port inside the battery compartment at the top. Carefully insert a micro USB cable (not included) into the port and run the cable through the opening at the bottom of the battery door.
  3. Replace the battery door and secure the screw.
  4. Plug the other end of the cable into an AC adapter (5v/500mA minimum), and insert the adapter into a wall outlet. AC power adapter not included.
    Visit www.byjasco.com/USB to purchase compatible accessories.

Jasco ZW6307 portable smart Motion sensor fig 2

Choose a location for the smart motion sensor
For portable use: The smart motion sensor works in almost any location – tabletops, counters, shelves, etc. Choose a location that allows the best viewing angle. The optimal position is at the edge of the selected surface at a height of 5ft. NOTE: Placing the smart motion sensor back from the edge will reduce the downward viewing angle. Do not place near humidifiers. air conditioners/vents or in direct sunlight. These areas will affect how the sensor detects motion.
For wall-mount use: Locate the wall-mount swivel base. Select the desired location. The recommended height is 6-8ft. Mount the swivel base to the location with the hardware provided Once the swivel base is secure, screw the smart motion sensor onto the swivel base and position it for the optimal viewing angle.Jasco ZW6307 portable smart Motion sensor fig
3

Test mode and setup Use test mode (S-second reset time) to make setup faster.

  1. To enter test mode, press and hold the button (C) on the back for 10 seconds. The LED on the front will flash blue, then red, then purple.
  2. Release the button. The reset time is now 5 seconds.
  3. Walk around in the detection area. When the sensor detects motion (red LED (lashes), stop and wait for 5 seconds. When the red LED flashes again, the sensor has reset and can be tested again

The smart motion sensor will remain in test mode for 10 minutes and automatically revert to the 4-minute default reset time in battery mode, or 20-seconds default reset time in USB power mode.

Normal operation

  • When powered, the smart motion sensor will flash a red LED one time when it initially detects motion.
  • Battery power – after motion is detected, the sensor waits 4 minutes before rechecking for motion.
  • During this time, the motion will not be detected. This helps conserve battery power.
  • Micro USB power (best accuracy) – motion is continuously monitored.
  • The battery level is reported to the gateway/controller once daily.
  • Advanced configurations are available to customize the operation. These configurations can be adjusted with a Z-Wave enabled controller that supports the Z-Wave configuration command class. For a complete list of advanced configurations, visit www.ezzwave.com/config

Z-WAVE INTEROPERABILITY

This product can he included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network.
This device supports Lifeline and notification (association group 1) supporting 5 nodes. Lifeline association supports the “device reset locally” function. Refer to the instructions of your controller for any available details on how this can be set.

Adjusting motion sensitivity

Jasco ZW6307 portable smart Motion sensor fig 5 You may want to adjust the sensitivity settings due to room size or pets. The smart motion sensor has three sensitivity levels – low. medium and high. Adjust sensitivity for room size or to help prevent false triggers.
The smart motion sensor is set to high sensitivity by default. To change the setting, refer to the table below. The sensor cycles through each setting. The next setting in the cycle is “low.” Press and hold the button (C) on the back of the sensor for 3 seconds, The LED on the front will flash blue once. This is the low setting. Press and hold the button again and the blue LED will flash twice. This is the medium setting. The cycle continues to the next setting each time. Refer to “test mode and setup” to test performance. (Distances are approximate)
Note: You must set the first mode in the list to move on to the next mode. Jasco ZW6307 portable smart Motion sensor fig 8

Jasco ZW6307 portable smart Motion sensor fig 4Adding your device in a Z-Wave network

  1. Follow the instructions for your Z-Wave certified controller to add the device in the Z-Wave network.
  2. Once the controller is ready to add your motion sensor, press and release the button on the sensor
  3. The blue LED will continue to flash quickly after it locates a network – the controller’s app will indicate if it discovers the sensor. If prompted by the controller to enter the S2 security code. refer to the OR code/security number on the back of the box or the OR code label on the product (see figure 3). Enter the 5-digit code.
  4. The blue LED will activate for 3 seconds to confirm it has been added to the network.
    You have complete control to turn your devices ON or OFF according to groups. scenes, schedules, and interactive automation when motion is detected by the sensor. Functions may vary depending on the gateway or controller.

NOTE: SmartStart-enabled products can be added to a Z-Wave network by scanning the OR code on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity
To remove and reset the device:

  1. Follow the instructions for your Z-Wave certified controller to remove the device from the Z-Wave network.
  2. Once the controller is ready to remove your motion sensor, press and release the button on the sensor. 3. The LED will blink S times.

To return your sensor to factory defaults and remove it from the network:

  1. Press the button 10 times within 6 seconds (interval between 2 presses of the button cannot be longer than 1 second).
  2. The blue LED will blink 3 times

NOTE: This should only be done in the event your network’s primary controller rs missing or otherwise inoperable.
https://byjasco.com/HEP-ET/20000-99999/39339

NOTE: The signal repeater function is determined when the product is added to the network. If the power option is changed, the sensor must be removed, manually reset, and added to the network under the new power option. If a manual reset is not performed, the signal repeater function will not be updated.

FCC IC
This device complies with Part 15 of the FCC and Industry Canada license- exempt RSS standards. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC NOTE : The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
Important note:
To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void the user’s authority to operate the device.

Responsible Party – US Contact Information
FCC — U2ZZW6307 I IC: 6924A-ZW6307
Jasco Products Company
CAN ICES-3(B)/NMB-3(B)
All brand names shown are trademarks of their respective owners.
MADE IN CHINA
DISTRIBUTED BY JASCO PRODUCTS COMPANY LLC, 10 E MEMORIAL RD.. OKLAHOMA CITY, OK 73114.
©JASCO 2020 152251 I ZW6307 I rev. 06/08/20 vl

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals