Fanvil i56A SIP Indoor Station Installation Guide
- June 6, 2024
- Fanvil
Table of Contents
i56A
Indoor Station
Quick Installation Guide
Package Contents
Physical specification
Dimension | 259 x 193 x 20 (mm) |
---|
- Panel
- Interface description
There are some interfaces on the back of the device for connecting power supply, alarms etc.
The connections are as follows:
No. | Description | Interface |
---|---|---|
1 | 1 set of RS485 interface: can be connected to the card reader, sensor, | |
etc. | ||
2 | 2 sets of short-circuit output interfaces: corresponding to the short- |
circuit input interface, login device webpage settings, can be connected to
electric locks, alarms, etc.|
3| 8 sets of alarm input interfaces: input devices for connecting switches,
infrared sensor, door sensor, vibration sensors, etc.|
4| Power interface: 12V/1A input.|
5| Ethernet interface: standard RJ45 interface, 10/100M adaptive, it is
recommended to use CATS or CAT5E network cable.|
3.
External device connection diagram
Installation (two models )
Model 1. Wall-mounted Installation
Step 1. Install wall bracket
Without 86 embedded box in the wall
A. According to the position of the cable in the wall, dig out a square hole
(heightwidthdepth=65.550.550mm) that can accommodate all cables.
B. Align the square hole of the wall bracket with the hole digged out before,
then mark the two fixation holes through the bracket on the wall.
C. Take down the bracket, using an electric drill to make the two fixation
holes on the wall,then insert the two screw fixing seats provided.
D. Fix the wall bracket on the wall with two TA4*30 screws.
With 86 embedded box in the wall
A. Make sure all cables in the embedded box.
B. Fix the wall bracket on the 86 embedded box with two PM4*16mm screws.
Step 2. Connect peripherals
A. If you need to connect other input and output devices, please connect to
the host through the cable.
Step 3. Power on the device. If it is working properly, align the slot on the
rear side of the panel with the pin on the wall bracket and slide the host
down to complete the installation.
Model 2. Desktop Installation
Align the slot on the rear side of the panel with the pin on the desktop
bracket and slide the bracket up to complete the installation.
Searching IP address
There are two methods as shown below to search the device. The default WAN
mode is DHCP.
Method 1: After booting, click “Settings”—“Common” to query.
Method 2: After booting, pull down the notification bar to query.
IP Indoor Station Setting
Step 1: Log in the web setting page of Indoor Station
Input IP address of the indoor station (e.g. http://172.18.90.14) into the
address bar of PC’s web browser.
The default user name and password are both admins.
Step 2: Add the SIP account
Set SIP server address, port, user name, password, and SIP user with assigned
SIP account parameters.
Select “Activate”, and then click Apply to save this setting.
Step 3: Feature Setting
Step 4: Unlock Setting
Application——Door phone Settings——Add——OK.
Title: Door Phone mode.
Number: The SIP account of Door Phone.
Line: The SIP line of Indoor Station.
Access codec: Consistent with the access code indoor phone access table (The
i56A as calling party)
Password: Same as open the door phone’s password (The i56A as called party)
Local Operation
-
Answer/hang-up calls
When the door phone calls the indoor station, click the button to answer the call, and click the button to hang up the call. -
Unlock the door
During the call of indoor station and door phone, click the button to unlock the door. -
Turn on/off the monitoring
Click the button on the indoor station to check the monitoring screen, and click the button again to exit. (Only support for the communication with video door phone) -
Volume adjustment
When the indoor station is talking to other devices like the door phone, click the button to increase the volume, and click the button to decrease the volume.
References