Quick Installation Guide
Package Contents
Physica Specifications
Device size | 160 x 93 x 35 mm |
---|---|
Weight | 450g (gross weight) |
(1)Front Panel
Interface | Description |
---|---|
Camera | Get the video |
Speaker | The door phone has a built-in speaker for convenient communication |
and alert use.
MIC| The door phone has a built-in microphone hidden in the pinhole located on
the front panel.
RFID Reader| Use RFID cards to unlock the door by touching the RFID reader of
the device.
Button Definition
Button | Description |
---|---|
DSS Key | Press the Button, calling or requesting to open the door. |
Numeric Keyboard | Input password to open the door or call. |
LED Definition
LED | Status | Description |
---|---|---|
Lock | Steady Blue | Door unlocking |
off | Door locking | |
Call & Ring | Blinks per second | Call Hold or Ringing |
off | On-Hook | |
Blinks every 3 seconds | The device in the issuing state | |
Steady Blue | Online talking |
Network & SIP
Registration| Blinks per second| Network error
off| The network is normal. SIP is not registered
Blinks every 3 seconds| SIP Registration failed
Steady Blue| SIP Registration succeeded
(2)Port Definition
After removing the Back Panel of i30, there is one terminal block connector
for power and lock control connection as shown in the picture below.
1 | 2 | 3 | 4 | 5 | 6 | 7 |
---|---|---|---|---|---|---|
+ DC12V | VSS | NC | COM | NO | S-IN | S-OUT |
12V DC Input | Electric-lock switch | Indoor switch |
Jp1 Jumper,
There are two modes for power supply of electric-lock as shown in the picture
below. (The default is “Passive Mode”).
Passive Mode: When the electric-lock starting current is more than 12V/500mA,
need to use the external drive mode, the electric lock interface for short
circuit output control. Active Mode: When the electric-lock starting current
is less than 12V/500mA, can use the internal drive mode, the electric lock
interface is 12V DC output.
Wiring instructions
NO: Normally Open Contact
COM: Common Contact
NC: Normally Close Contact
Driving Mode | Electric lock Mode | Jp1 Jumper | Connections |
---|---|---|---|
Active | Passive | No electricity when open | Electrify when open |
√ | |||
√ | √ | ||
√ | √ |
content/uploads/2021/10/Fanvil-IP-Door-Phone-i30-connection-4.jpg)
| √| | √| |
| √| √| | |
Installation
Step 1: Installation preparation
A. Check the following contents:
Hex wrench x 1
RJ45 plugs x 2 (1 spare)
KA4 x 25mm screws x 4
25mm screw anchors x4
B. Tools that may be required:
Hex wrench
Phillips screwdriver (Ph2 or Ph3), hammer, RJ45 crimper
Electric impact drill with a 6mm drill bit
Step 2: Drilling
A.Place the mounting template with dimensions on the surface of a wall in a
desired flat position.
B.Use an electric drill to drill the 4 holes marked on the mounting template.
It is recommended to drill about 30mm deep. Remove the template when finishing
drilling.
C.Push or hammer screw anchors into the drilled holes.
Step 3: Removing hanging shell
A. Remove the hanging shell in Figure 3 and Figure 4.
B. With Phillips screwdriver unpacks the Back Panel and the main part of intercom as shown in Figure 5.
Step 4: Hanging shell Fixing and Cabling
A. Select the hole for cable supply; cable length of 15cm to 20cm is
recommended.
B. With 4 KA5 x 25mm screws, tighten the Wall-mounted hanging shell as shown
in Figure 6.
Step 5: Connection line
A. Select the hole for cable supply.
B. Connect the cables of RJ45, power, and electric lock to the motherboard
socket as mentioned in the connector’s description (refer to Section 2).
C. Test whether there is electricity by doing the following:
Press the tt button for 3 seconds to get the IP address of the intercom by
voice.
Input access password or press the indoor switch to check the electric-lock
installation.
Note: Do not proceed to mount until you have finished the electric checking.
Step 6: Mounting
A. Use the 4 screws to tighten the main part of the intercom on the back panel
as shown in Figure 9.
B. Push the device into the Wall-mounted hanging shell and tighten it with 1
screw as shown in Figure 10.
C. Make sure the screws have been tightened properly for a better waterproof
effect.
Searching Door Phone
There are two methods as shown below to search the i30.
Method 1:
Open the door phone Network Scanner. Press the Refresh button to search the
i30 and find the IP address.
(Download addresshttp://downloadanvil.com/tool/iDoorPhoneNetworkScannerexe )
Method 2:
Press and hold the It” key for 3 seconds and the door phone will report the IP
address by voice.
Default Setting
Default DHCP Client| Enable
Static IP Address| 192.168.1.128
Default Web Port| 80
Default Login User Name| admin
Default Login Password| admin
Display IP address| Hold # for 3 seconds to display by voice
Search Tools| iDoorPhone Network Scanner
SIP Door Phone Setting
Step 1: Log in to the homepage of 130.
Step 2: Add the
SIP account.
Set SIP server address, port, user name, password, and SIP user with assigned
SIP account parameters.
Select “Activate”, and then click Apply to save this setting.
Step 3:
Setting DSS key
Set the DSS key as shown below for a quick start. Click “Apply” to save this
setting.
Type: Hot Key
Number 1: The DSS Key will dial to this Number 1.
Number 2: If Number 1 is unavailable, it will be forwarded to Number 2.
Line: Working line
Subtype: Speed dial
Step 4: Door Phone Setting
Door Unlocking Setting
Local
(1)Local Password
Step 1: Go to EGS Setting → Features→ Set Local Password (The default is
“6789”).
Step 2: Use the device’s Numeric Keyboard to input the password and “#” key,
and then the door will be unlocked. (2)Private Access Code
Step 1: Go to EGS Access → Access Rule → set Access Code.
Step 2: Use the device’s Numeric Keyboard to input the password and “#” key,
and then the door will be unlocked.
Remote Password
Step 1: Go to EGS Setting → Features →Set Remote Password (The default is
“‘”).
Step 2: To answer the call made by the visitor via SIP phone, press the” key
to unlock the door for the visitor.
RFID Card
Step 1: Go to EGS Access Enter the Name and ID Number (Only Front 10 yards)
Press Add to Access Table.
Step 2: Use pre-assigned RFID cards to unlock the door by touching the RFID
area of the device.