AURORA AU-ADST Primo™ Fire Rated Can for Fixed Primo™ – Electrical 4 Less Instruction Manual
- June 3, 2024
- Aurora
Table of Contents
AU-ADST Primo™ Fire Rated Can for Fixed Primo™ – Electrical 4 Less
Instruction Manual
INSTALLING STANDARD VERSION (AU-ADSTxxxx)
REMOVE BEZEL FROM FIXTURE| REMOVE LIGHT FROM INNER BAFFLE
REFER TO LUMINAIRE’S INSTALLATION GUIDE TO INSTALL
INSTALLING GU10 VERSION (AU-ADGUSTxxxx)
REMOVE BEZEL FROM FIXTURE| REMOVE LIGHT FROM INNER BAFFLE
REFER TO LUMINAIRE’S INSTALLATION GUIDE TO INSTALL
IMPORTANT INSTALLATION INFORMATION
- Installation should be carried out by a qualified electrician in accordance with the latest edition of the National wiring regulations.
- These luminaires are for indoor use only,
- Maximum Input Voltage– 240VAC 50Hz
- Ensure that ALL electrical connections are tight with no loose strands.
- Before commencing installation or maintenance, ensure electricity is switched off at the mains.
- GU10/Driver – Class II, Double Insulated an earth is not required. Earth terminal is for Termination only.
- Module – Class III Luminaire. Must not be connected to a mains supply without the driver.
- These downlights must be disconnected before insulation resistance testing of the lighting circuit.
- Brown – (L) Live, Blue – (N) Neutral
- Please Note: May not be compatible with PIR’s. Please contact sales office for compatibility.
- We do not recommend mixing LEDs circuits with products such as extractor fans. This is due to the sensitive nature of LED’s and is not product specific.
- (AU-ADSTxxxx only) This luminaire is dimmable. Please check Aurora website for compatibility.
Aurora Limited
6 Little Burrow,
Burrowfields,
Welwyn Garden City,
AL7 4SW, United Kingdom