EN-BAl222EMMS, EN-BAl243EMMS, EN-BA1533EMMS
EN-BA1563EMMS, EN-BA1839EMMS & EN-BA1873EMMS
****Class I
Document Version EN-BA1XXXEMMS_V1_21

MICROWAVE SENSOR

DETECTION AREA
Detection area can be reduced by selecting the combination on the DIP switches to fit precisely each application.
HOLD TIME Refers to the time period the lamp remains at 100% illumination after no motion detected.
DAYLIGHT SENSOR
Aurora EN-BA1222EMMS Single Microwave Emergency LED Batten fig
8
The sensor can be set to only allow the lamp to Illuminate below a defined ambient brightness threshold. When set to Disable mode, the daylight sensor will switch on the lamp when motion is detected regardless of ambient light level. 50lux: twilight operation, 101ux, 2Iux: darkness operation only.

IMPORTANT INSTALLATION INFORMATION

  • Installation should be carried out in accordance with the current edition of the National Wiring Regulations. If in doubt, consult a qualified electrician.
  • These luminaires are for Indoor use only
  • Maximum input Voltage— 220-240V AC 50/60Hz
  • Ensure that ALL electrical connections are tight with no loose strands.
  • Before commencing installation or maintenance, ensure electricity is switched off at the mains.
  • Batteries must be charged for 24 hours to ensure full emergency duration and before testing.
  • Class I, mahs voltage, this luminaire must be earthed.
  • This luminaire is not dimmable Permanent Live to Terminal marked – LI Switched Live to terminal marked – L Neutral to terminal masked N
  • The green charging indicator will be visible when in normal operation and also when switched off.
  • We do not recommend mbdng LEDs circuits with products such as extractor fans. This Is due to the sensitive nature of LEDs and Is not product specific
  • This product contains a light source of energy efficiency class D.

Emergency Installation and Inspection

Installation / Test
Record| Serial / Luminaire Number|
---|---|---
Installed By:| | Date:|
Commissioned By:| | Date:|
| Year 1| Year 2| Year 3| Year 4
The battery must be replaced
---|---|---|---|---
Monthly test| Signed| Date| Signed| Date| Signed| Date| Signed| Date
1| | | | | | | |
2| | | | | | | |
3| | | | | | | |
4| | | | | | | |
5| | | | | | | |
6| | | | | | | |
7| | | | | | | |
8| | | | | | | |
9| | | | | | | |
10| | | | | | | |
11| | | | | | | |
12| | | | | | | |

Environmental Protection (W.EEE.) — Aurora’s WEEE Reg.No. WEE/BG0130YX (UK Only)
Waste Electrical & Electronic Equipment Regulations (WEE) requires that any of our products showing this marking (left) must not be disposed of with other household or commercial waste. Aurora does not levy any WEE disposal charges to its customers for affected WEE related products. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate any such product from other waste types and recycle it responsibly at your local facilities. Check with your Local Authority, Recycling Centre or retailer for recycling advice. If, when you purchased any Aurora product, your supplier included a WEEE disposal fee, you should then contact your supplier for advice on his take back of the product for the correct disposal.

GUARANTEE

This luminaire is guaranteed fora period of 5 years from the date of purchase. The emergency battery/inverter is guaranteed fora period of 1 year from the date of purchase. The guarantee is invalid in the case of improper use, installation, tampering, and removal of the 0.G date label, installation in an improper working environment or installation not according to the current edition of the National Wiring Regulations. Should this product fail during the guarantee period it will be replaced free of charge, subject to correct installation and return of the faulty unit. Aurora does not accept responsibility for any installation costs associated with the replacement of this product This warranty is in addition to the statutory rights in your country of purchase. Aurora reserves the right to alter specifications without prior notice.