DonJoy® ISOFORMTM LO
Patient Application Instructions
BEFORE USING THE DEVICE, PLEASE READ THE INSTRUCTIONS FOR USE COMPLETELY AND CAREFULLY. CORRECT APPLICATION IS VITAL TO THE PROPER FUNCTIONING OF THE DEVICE.
TO REMOVE BRACE:
To remove the brace, first, loosen it by detaching the pull tab from the loop exterior. Then unhook the donning mitt from the loop exterior and take off the brace.
TO RE-APPLY BRACE:
Step 1. Loosen the Brace
Loosen the brace by detaching the pull tab from the loop exterior. Pull the
belt wings in opposite directions. (Fig. A) Step 2. Position the Brace
Center the rear section of the belt at the midline of the lower back, so that
the belt is just above the crease of the buttocks. Note: The brace is intended
to be worn over clothing.
Step 3. Secure the Brace
Secure the hook portion of the donning mitt to the loop exterior. (Fig. B)
Before tightening the brace, make sure the rear panel section is positioned
evenly on both sides. To tighten the brace, slip your thumbs through the holes
in the pull tabs and pull the tabs away from your body. Secure the pull tabs
to the loop exterior. Adjust the compression as needed.
HELPFUL TIP: BRACE MIGRATION
To reduce brace migration, follow these easy steps. Before sitting, loosen
the brace by detaching the pull tabs. Once seated, tighten the pull tabs by
pulling across the body and re-adhering to the loop exterior. When standing
up, readjust pull tabs.
HOT/COLD PACK :
If you plan to use a hot/cold pack with the LO+, follow the instructions on the hot/cold pack. Insert hot/cold pack into a pocket and adhere to the back panel.
USE & CARE INSTRUCTIONS:
Only the soft goods can be wet-cleaned. Before cleaning, open the rear panel
pouch and detach the waist belt. (Fig.F) Remove the rigid rear panel from the
pouch. To detach the pull tab section, detach the rear panel section by
unlooping the waist belt from the lacing guide panel. Follow the same steps in
reverse to put the brace back together after washing. Hand washes in cold
water, less than 86°F (30°C), using a mild soap. Air dry.
NOTE: If not rinsed thoroughly, residual soap may cause irritation and
deteriorate the material.
Do NOT iron. Do NOT tumble dry. Do NOT bleach.
WARNINGS AND CAUTIONS:
If you experience any pain, swelling, sensation changes, excessive
discoloration, irritation to the skin, or any unusual reaction while using
this product, consult your medical professional. If any distortion of the
support panels, fraying, or deterioration of lace cables is noticed,
discontinue use. The brace is intended to be worn over clothing. The brace
should be appropriately sized to the patient to ensure proper support and
function. If the brace does not fit properly, it may be reshaped and adjusted
by a healthcare professional. Care should be taken with patients, especially
the elderly, not to apply the brace too tightly, which MAY cause excessive
pressure. Patients should be instructed on appropriate tensioning during
ongoing use. The patient should see a healthcare professional for a
replacement if a product quality issue occurs within the warrantied timeframe.
The brace should not be exposed to moisturizers, chemicals, or solvents, as
they may affect durability.
MATERIAL CONTENTS:
Nylon, Polyester, Polyethylene, Polyurethane, Cotton, Acrylic, Polypropylene,
Calcium Carbonate, PVC, Synthetic Rubber, Silicone, EVA
NOT MADE WITH NATURAL RUBBER LATEX
WARRANTY:
DJO, LLC will repair or replace all or part of the unit and its accessories
for material or workmanship defects for a period of six months from the date
of sale. To the extent the terms of this warranty are inconsistent with local
regulations, the provisions of such local regulations will apply.
RX ONLY. INTENDED FOR SINGLE PATIENT USE.
Individual results may vary. Neither DJO, LLC nor any of its subsidiaries
dispense medical advice. The contents of this document do not constitute
medical, legal, or any other type of professional advice. Rather, please
consult your healthcare professional for information on the courses of
treatment, if any, which may be appropriate for you.
DJO, LLC I A DJO Global Company T 800.336.6569 D 760.727.1280 F
800.936.6569
1430 Decision Street I Vista, CA 92081-8553 I U.S.A.
DJOGlobal.com