The TELEFUNKEN Small Diaphragm Condenser Series features the vacuum tube-based ELA M 260 and the phantom-powered M60 FET microphones, both of which accept the thread-on TK6x Series capsules. Both amplifiers have their strengths, be it the ELA M 260’s natural warmth and clarity or the M60’s low self noise and ultra fast transient response. All assembly and testing of the Small Diaphragm Condenser Series occurs in TELEFUNKEN’s American facility. Depending on the system configuration, different capsule combinations will be included. Please see the System Specifications for more information. Additional capsules and accessories are available for purchase directly from TELEFUNKEN.
Specification | ELA M 260 | M60 FET |
---|---|---|
Amplifier Type | Tube (5840W) | FET |
Frequency Range | 20 Hz – 20 kHz, ±3 dB | 20 Hz – 20 kHz, ±3 dB |
Power Source | External Power Supply | +48V Phantom Power |
Transformer | TELEFUNKEN Elektroakustik T60 | TELEFUNKEN Elektroakustik T61 CT |
Sensitivity | 19.5 mV/Pa, ±1 dB | 10 mV/Pa, ±1 dB |
THD at 1 kHz, 1 Pa | <0.15% | <0.01% |
Output Impedance | 200Ω | 120 Ω |
Maximum SPL | 135 dB | > 135 dB |
S/N Ratio | 83 dBA | 89 dBA |
Self-Noise | 11 dBA | 5 dBA |
Dimensions | 140 mm x 20 mm | 140 mm x 20 mm |
Weight | 116 g | 110g |
Capsule Specifications
TK6x Series interchangeable capsules feature a 15 mm diameter, 6-micron gold- sputtered membrane. They are designed to easily thread on and off the amplifier body. All TK6x Series capsules are held to a strict ± 1 dB sensitivity tolerance and individually tested and matched by frequency response in TELEFUNKEN’s American facility.
TK60 Cardioid: Flat from 150 Hz to 7 kHz with a presence peak at 8 kHz, ideal
for drum overheads, acoustic guitar, and other acoustic instruments.|
---|---
TK61 Omnidirectional: Flat from 20 Hz to 5 kHz with a presence peak at 8 kHz.
Use with SD40 diffuse field spheres to make the upper midrange frequencies
more directional.|
TK62 Hypercardioid: Flat from 150 Hz to 3 kHz with a dip at 6 kHz and a
presence peak at 8 kHz, excellent for cymbals, percussion, and as a stereo
pair for live performance recording.|
Additional capsules are available for purchase through the TELEFUNKEN Elektroakustik webstore: www.t-funk.com/shop
ELA M 260 Tube
One of the few small diaphragm tube microphones available today, the ELA M 260 is an absolute first choice for acoustic instrument recording. Everything from stringed instruments to drum overheads will benefit from the 260’s perfect combination of small diaphragm precision and classic tube warmth. Its tonality and detail when capturing acoustic instruments, especially strings, brass, woodwind and percussion, is unrivaled. Handassembled in America, the ELA M 260 features a NOS 5840W vacuum tube, premium through hole components and an American-made transformer.
Quick Start Guide
- Attach the included shock mount onto a microphone stand.
- Push the microphone through both sets of elastics of the mount.
- Plug the included 7-pin tube microphone cable into the microphone then into the power supply.
- Make sure the power supply is set to the correct mains voltage (115V or 230V). Plug the included power cable into the power supply, then into mains power.
- Connect a standard 3-pin microphone cable (not included) to the power supply and then to your microphone preamplifier input.
- Turn on the power supply. Let the system warm up for 10 minutes before use.
ELA M 260 System Configurations
System| Cardioid| Master| Sereo| Saster Stereo|
Master Tri-Mono
---|---|---|---|---|---
TX60 Cardioid Capsule| X| X| 2X| 2X| 3X
1X61 Omni Capsule| | X| | 2X| 3X
TK62 Hyper Capsule| | X| | 2X| 3X
M 963 Tri Power Supply| | | | | X
M 9605 Dual Power Supply| | | X| X|
M 902 Power Supply| X| X| | |
M 860 Tube Microphone Cable| X| X| 2X| 2X| 3X
M 761 Shock Mount| X| X| 2X| 2X| 3X
ZC60 Zipper Case| X| X| | |
FC6OS Flight Case| | | X| X|
FC6OT Flight Case| | | | | X
SD40 Diffusion Sphere| | | | | 3X
WS20 Windscreen| X| X| 2X| 2X| 3X
Safety Warning: Vacuum tube microphones, their associated power supplies, and their cables carry potentially harmful voltages. Make sure all connections are made before powering on your microphone system. Do not open your microphone or power supply while it’s connected to mains power and powered on. If your microphone stops working, turn it off and visit www.t-funk.com/repairs for information on repairing your product.
M60 FET
The M60 is a re-interpretation of the classic phantom-powered pencil mic, featuring exceptional transient response and high SPL handling capabilities. Paired with its impressive clarity and subtle tonality, the M60 excels at capturing acoustic and percussive instruments both in the studio and on the stage. The M60 is hand-assembled in America using premium components and utilizes an ultra-clean, true class-A discrete circuit paired with an American-made transformer. Its unique circuit topology captures a wide frequency range, which means life-like capturing of most sources.
Quick Start Guide
- Attach the included shock mount onto a microphone stand.
- Push the microphone through both sets of elastics of the mount.
- Plug the included SGMC-5R 3-pin XLR cable into the microphone then into your microphone preamplifier input.
- Apply +48V phantom power from your microphone preamplifier. Allow the microphone 15 seconds to power up before use.
M60 System Configurations
System| M60| M61| M62| Master| Stereo| Master
Stereo| Omni Tri-Mono| Deluxe Tri-Mono
---|---|---|---|---|---|---|---|---
TK60 Cardioid Capsule| X| | | X| 2X| 2X| | 3X
TK61 Omni Capsule| | X| | X| | 2X| 3X| 3X
TK62 Hyper Capsule| | | X| X| | 2X| |
M 761 Shock Mount| X| X| X| X| 2X| 2X| 3X| 3X
SGMC-5R XLR Cable| X| X| X| X| 2X| 2X| 3X| 3X
ZC61 Zipper Case| X| X| X| X| | | |
ZC62 Dual Zipper Case| | | | | X| X| |
ZC63 Tri Zipper Case| | | | | | | X| X
WS20 Windscreen| X| X| X| X| 2X| 2X| 3X| 3X
Operating Conditions
Because the M60 is a phantom-powered microphone, a +48V source is necessary
for operation. Phantom power is provided through most mixers, consoles, and
preamplifiers as a standard feature. Please note that the microphone should be
muted when engaging phantom power, as it can produce a loud pop as it turns
on.
Recommended Stereo Configurations
ORTF: Use TK60 Cardioid capsules. Angle the two microphones 110 degrees
apart with the capsules spaced 17 cm. ORTF is designed to mimic the placement
of the human ears.|
---|---
A/B or Spaced Pair: Use TK60 Cardioid or TF61 Omnidirectional capsules.
Position the two microphones parallel to each other. Recommended spacing is 60
cm, though spacing up to 3 meters can be used depending on the distance from
the source, the environment, and the desired stereo width.|
XY: Use TK60 Cardioid or TK62 Hypercardioid capsules. Angle the two
microphones 90 degrees apart with the center of the capsules directly over
each other. The capsules should be as close as possible without touching. This
technique will sound more direct than other techniques listed and should
always be phase coherent.|
Decca Tree: Use TK61 Omnidirectional capsules with SD40 diffuse field
spheres. Position the Left and Right microphones 2 meters apart, with the
Center microphone 1.5 meters in front. Distances can be adjusted but should
not be less than 1.5 meters. The Left and Right microphones can be angled
outwards up to 90 degrees.|
Tips:
-
Remember to check for phase cancellation!
-
Cardioid capsules will lose low end with distance, while Omnidirectional capsules will retain low frequency information.
-
Omnidirectional capsules will pick up more ambient noise, so Cardioid and Hypercardioid capsules are recommended for less than ideal recording environments.
Warranty
TELEFUNKEN Elektroakustik warrants that any capsules and tubes used in their
microphones are free from defects in material and workmanship for the period
of ninety (90) days from the original date of purchase, and agree to replace
any capsule or tube which, under normal installation and use, disclose such
defect. This is provided that the complete microphone is delivered to
TELEFUNKEN Elektroakustik intact for examination and provided that such
examination discloses, in the judgment of TELEFUNKEN Elektroakustik, that the
tube or capsule is indeed defective. Upon replacement, TELEFUNKEN
Elektroakustik will provide an additional 90-day limited warranty on the new
capsule or tube.
This warranty does not extend to any capsule or tube which appears to have
been misused, altered, neglected, damaged, or stored in any manner that
adversely affects it, or used in violation of instructions furnished by us.
This limited warranty shall be void and of no further force or effect
whatsoever if the microphone is repaired or modified by any person other than
an authorized representative of TELEFUNKEN Elektroakustik. This warranty shall
not apply to any defect, failure, or damage caused in whole or in part from
attempts by personnel other than TELEFUNKEN Elektroakustik’s to open, repair,
or service the microphone; nor to damage to a unit which has been modified by
persons other than TELEFUNKEN Elektroakustik personnel.
In compliance with the following requirements:
EMC Directive: 2014/30/EU (EN 55013 applied)
Low Voltage Directive: 2014/35/EU (EN 60065 applied)
RoHS2 Directive: 2011/65/EU
Product Registration
All TELEFUNKEN Elektroakustik customers are encouraged to register recently purchased NEW or USED products. All warranties on Diamond, Alchemy, and SDC Series products are fully transferable between owners for the length specified for each series starting from the date the microphone was purchased as new. Microphones come with a 90-day warranty for capsule and tube. A one-year warranty covers parts and labor on the amplifier as well as the power supply. Upon registering your new products, the warranty will be increased to one year parts and labor for the capsule and tube, and four years for the amplifier and power supply. To register your warranty, please head to www.t-funk.com/warranty to fill out the Product & Warranty Registration form.
Repairs & Service
Repairs on new TELEFUNKEN Elektroakustik microphones are covered under a limited warranty plan and repair costs will be determined based upon the date of purchase and the date in which the warranty was registered. Repairs & Service covered under the warranty plan are done at no charge for labor, parts and service. Please visit www.t-funk.com/repairs for more information on repairing your TELEFUNKEN microphone.
Diamond Series
| Mynamic Series & Drum Packs
---|---
Alchemy Series
| Direct Boxes
Tubes, Accessories, Merch & More!
|
www.t-funk.com
300 Pleasant Valley Rd, Suite C, South Windsor. CT 06074
+1.860.882.5919
References
- Microphone Repairs - Telefunken Elektroakustik
- Shop - Telefunken Elektroakustik
- Warranty Registration - Telefunken Elektroakustik
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>