Goodman R410A FTXNG-A Series Inverter Split Unit Air Conditioner Wall Mounted User Manual

June 9, 2024
Goodman

Goodman R410A FTXNG-A Series Inverter Split Unit Air Conditioner Wall

Mounted

Goodman R410A FTXNG-A Series Inverter Split Unit Air Conditioner Wall
Mounted-product

Product Information: Inverter Split Unit Air Conditioner Wall

Mounted Heatpump [60Hz] FTXNG-A Series R410A

The Inverter Split Unit Air Conditioner is a wall-mounted air conditioning unit that uses a heat pump to cool or heat a room. It operates on a power supply of 1Phase, 208/230V, 60Hz, and is part of the FTXNG-A Series that uses R410A refrigerant. The indoor unit models available are FTXNG09AXVJU, FTXNG12AXVJU, and FTXNG18AXVJU, while the outdoor unit models available are RXNG09AXVJU, RXNG12AXVJU, and RXNG18AXVJU. The unit is designed with different features such as an inverter, scroll compressor, rotary compressor, power- airflow flap, comfortable wide-angle louvers, and more for efficient and comfortable cooling or heating.

Product Usage Instructions

Installation:

Installation must be performed by a qualified technician following the instructions provided in the installation manual.

Operation

  1. Turn on the power supply.

  2. Press the ON/OFF button on the indoor unit or use the remote control to turn on the air conditioner.

  3. Select the desired mode (cooling, heating, fan only or dry function) and temperature using the remote control.

  4. Use the timer function to set the air conditioner to turn on or off at a specific time.

  5. Use the quiet operation mode for silent operation during the night.

  6. Use the intelligent eye operation mode to automatically adjust the temperature and airflow direction based on human presence in
    the room.

  7. Use the energy-saving function for efficient operation and reduced energy consumption.

  8. Use the Anti-virus Filter/Gin-ION Filter, Catechin Filter/Green Tea Filter, or Titanium Apatite Air-Purifying Filter to improve air quality.

Maintenance

  1. Regularly clean the air filter to maintain optimal performance.
  2. Refer to the user manual for instructions on cleaning the air conditioner.
  3. Use a soft, damp cloth to clean the surface of the unit.
  4. Do not use harsh chemicals or abrasive materials to clean the unit.

For more information on usage, refer to the user manual provided with the product.

Introduction

Model Name and Power Supply

Indoor Unit Outdoor Unit Power Supply
FTXNG09AXVJU RXNG09AXVJU ****

1Phase, 208/230V, 60Hz

FTXNG12AXVJU| RXNG12AXVJU
FTXNG18AXVJU| RXNG18AXVJU

Indoor Unit

Definition Description
Unit Category F
Product Type T
System X
Grade N
Brand G
**Capacity Indication*** 09
Major Design Category A
Factory Origin X
Power Supply VJ
Country U

Outdoor Unit

Definition Description
Unit Category R
System X
Grade N
Brand G
**Capacity Indication*** 09
Major Design Category A
Factory Origin X
Power Supply VJ
Country U

Functions




Category

| ****



Functions

| ****


FTXNG09/12A RXNG09/12A

| ****


FTXNG18A RXNG18A

---|---|---|---


Basic Function

| Inverter| ●| ●
Operation Limit for Cooling (°CDB)(O/D)| 10 – 46| 10 – 46
Operation Limit for Cooling (°FDB)(O/D)| 50 – 114.8| 50 – 114.8
Operation Limit for Heating (°CWB)(O/D)| -15 – 18| -15 – 18
Operation Limit for Heating (°FWB)(O/D)| 5 – 64.4| 5 – 64.4


Compressor

| Scroll Compressor| –| –
Swing Compressor| ●| ●
Rotary Compressor| –| –



Comfortable

Airflow

| Power-airflow Flap| ●| –
Power-airflow Dual Flaps| –| ●
Power-airflow Diffuser| –| –
Wide Angle Louvers| ●| ●
Vertical Auto-Swing (Up and Down)| ●| ●
Horizontal Auto-Swing (Right and Left)| –| –
3D Airflow| –| –
Breeze Airflow| –| –


Comfort Control

| Auto Fan Speed| ●| ●
Indoor Unit Quiet Operation| ●| ●
Intelligent Eye Operation| –| –
Automatic Defrosting| ●| ●


Operation

| Automatic Operation| ●| ●
Programme Dry Function| ●| ●
Fan Only| ●| ●



Lifestyle Convenience

| Powerful Operation (Non Inverter)| –| –
Inverter Powerful Operation| ●| ●
Energy Saving Function| ●| ●
Sleep Mode| ●| ●
Indoor Unit ON/OFF Button| ●| ●
R/C with Backlight| ●| ●
Signal Receiving Sign (R/C)| ●| ●
Set Temperature Display (R/C)| ●| ●




Health & Clean

| Saranet Filter| –| –
Anti-virus Filter / Gin-ION Filter| –| –
Catechin Filter / Green Tea Filter| ●| ●
Titanium Apatite Air-Purifying Filter| ●| ●
PM 2.5 Filter| –| –
Streamer| –| –
Plasma| –| –
Wipe Clean Flat Panel| ●| ●


Timer

| Weekly Timer Operation (Wired R/C)| –| –
24-hour ON/OFF Timer (R/C)| ●| ●
Countdown ON/OFF Timer (R/C)| –| –
Worry Free (Reliability & Durability)| Auto Restart (after Power Failure)| ●| ●
Self-diagnosis| ●| ●
Anti-corrosion Treatment of Outdoor Heat Exchanger| Blue Fin| Blue Fin
Flexibility| Pre-charged Piping Length| 32-13/16 ft| 32-13/16 ft
Either Side Drain (Right or Left)| ●| ●


Remote Control

| WIFI Connectivity| ●| ●
BAG Connectivity| ●| ●
DIII-NET Connectivity| –| –
Remote Controller| Wireless| BRC52B67| BRC52B67
Wired| –| –

Note:
● : Available
– : Not Available

  • : Optional (Refer to DAMA Spare Part team for more details on optional items.)

Specifications

MODEL

| INDOOR UNIT| FTXNG09A
---|---|---
OUTDOOR UNIT| RXNG09A

Cooling                                            Heating

|
Rated Capacity (Min. ~ Max.)| kW| 2.57 (1.30 – 3.00)| 2.75 (1.30 – 3.80)
Btu/h| 8800 (4400 – 10200)| 9400 (4400 – 13000)
Moisture Removal| gal/h| 0.09
Rated Running Current| A| 3.82| 3.70
Rated Power Consumption| W| 800| 774
EER2| Btu/h/W| 11.0| N/A
SEER2| 18.0| N/A
COP| W/W| N/A| 3.56
HSPF2| N/A| 9.0
Power Factor (Rated)| N/A
Piping Connections| Liquid| inch (mm)| 1/4” (6.35)
Gas| inch (mm)| 3/8” (9.52)
Refrigerant| Type| R410A
Charge| lbs (kg)| 1.54 (0.7)
Max. Interunit Piping Length| ft (m)| 65-5/8 (20)
Max. Interunit Height Difference| ft (m)| 32-13/16 (10)
Chargeless| ft (m)| 32-13/16 (10)
Amount of Additional Charge of Refrigerant| oz/ft (g/m)| 0.21 (20)
Drawing No.| 3D143694C
INDOOR UNIT| FTXNG09A
Front Panel Colour| WHITE

Airflow Rate

| Turbo| CFM| 466
High| CFM| 431| 402
Medium| CFM| 322
Low| CFM| 249
Quiet| CFM| 142| 219
Sound Pressure Level (H/M/L/Q)| dBA| 43/36/29/19| 42/35/29/25

Fan

| Type| CROSS FLOW
Drive| DIRECT
Speed| 3 STEPS, QUIET, AUTO, TURBO

Fan Motor

| Type| DIRECT CURRENT
Motor Output| W| 22
Running Current (Rated)| A| 0.10
Power Consumption (Rated)| W| 29
Air Direction Control| UP, DOWN, LEFT, RIGHT
Air Filter| CATECHIN
Dimensions (H x W x D)| inch (mm)| 11-1/3 x 30-5/16 x 9-3/16 (288 x 770 x 234)
Packaged Dimensions (H x W x D)| inch (mm)| 13-7/8 x 32-3/4 x 12-3/8 (350 x 830 x 314)
Weight| lbs (kg)| 20.3 (9.2)
Gross Weight| lbs (kg)| 24.7 (11.2)
Condensate Drain Size| inch (mm)| 5/8 (16)
Document No.| 3D143550B
OUTDOOR UNIT| RXNG09A
Casing Colour| IVORY WHITE
Airflow Rate| High| CFM| 1083| 1103
Sound Pressure Level| dBA| 46| 48
Fan| Type| PROPELLER
Drive| DIRECT

Fan Motor

| Type| DIRECT CURRENT
Index of protection (IP)| 24
Insulation Grade| E
Running Current (Rated)| A| 0.60
Power Consumption (Rated)| W| 32
Motor Output| W| 26
Poles| 8

Compressor

| Type| HERMETIC SWING
Model| 1YC23AUXDA
Oil type| DAPHNE FVC50K
Oil amount| oz (cm 3 )| 12.4 (375)
Heat Exchanger Type| FIN TUBE
Dimensions (H x W x D)| inch (mm)| 21-11/16 x 26-1/2 x 11-3/16 (550 x 675 x 284)
Packaged Dimensions (H x W x D)| inch (mm)| 24-1/64 x 31-3/8 x 15-1/8 (610 x 801 x 384)
Weight| lbs (kg)| 55 (25)
Gross Weight| lbs (kg)| 62 (28)
Document No.| 3D143595A

  1. ALL UNITS ARE BEING TESTED ACCORDING TO AHRI 210/240 STANDARD.
  2. ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
COOLING HEATING
INDOOR: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB) INDOOR: 70°FDB (21.1°CDB)
OUTDOOR: 95°FDB (35°CDB) OUTDOOR: 47°FDB (8.3°CDB) / 43°FWB(6.1°CWB)

MODEL

| INDOOR UNIT| FTXNG12A
---|---|---
OUTDOOR UNIT| RXNG12A

Cooling                                            Heating

|
Rated Capacity (Min. ~ Max.)| kW| 3.22 (1.30 – 3.90)| 3.31 (1.30 – 4.81)
Btu/h| 11000 (4400 – 13300)| 11300 (4400 – 16400)
Moisture Removal| gal/h| 0.18
Rated Running Current| A| 3.22| 4.55
Rated Power Consumption| W| 1294| 1004
EER2| Btu/h/W| 8.5| N/A
SEER2| 18.0| N/A
COP| W/W| N/A| 3.30
HSPF2| N/A| 9.0
Power Factor (Rated)| N/A
Piping Connections| Liquid| inch (mm)| 1/4” (6.35)
Gas| inch (mm)| 3/8” (9.52)
Refrigerant| Type| R410A
Charge| lbs (kg)| 2.09 (0.95)
Max. Interunit Piping Length| ft (m)| 65-5/8 (20)
Max. Interunit Height Difference| ft (m)| 32-13/16 (10)
Chargeless| ft (m)| 32-13/16 (10)
Amount of Additional Charge of Refrigerant| oz/ft (g/m)| 0.21 (20)
Drawing No.| 3D143694C
INDOOR UNIT| FTXNG12A
Front Panel Colour| WHITE


Airflow Rate

| Turbo| CFM| 473
High| CFM| 436| 412
Medium| CFM| 316
Low| CFM| 247
Quiet| CFM| 132| 210
Sound Pressure Level (H/M/L/Q)| dBA| 45/37/31/19| 43/36/30/26


Fan

| Type| CROSS FLOW
Drive| DIRECT
Speed| 3 STEPS, QUIET, AUTO, TURBO


Fan Motor

| Type| DIRECT CURRENT
Motor Output| W| 22
Running Current (Rated)| A| 0.10
Power Consumption (Rated)| W| 29
Air Direction Control| UP, DOWN, LEFT, RIGHT
Air Filter| CATECHIN
Dimensions (H x W x D)| inch (mm)| 11-1/3 x 30-5/16 x 9-3/16 (288 x 770 x 234)
Packaged Dimensions (H x W x D)| inch (mm)| 13-7/8 x 32-3/4 x 12-3/8 (350 x 830 x 314)
Weight| lbs (kg)| 21.4 (9.7)
Gross Weight| lbs (kg)| 25.8 (11.7)
Condensate Drain Size| inch (mm)| 5/8 (16)
Document No.| 3D143550B
OUTDOOR UNIT| RXNG12A
Casing Colour| IVORY WHITE
Airflow Rate| High| CFM| 1051| 966
Sound Pressure Level| dBA| 48
Fan| Type| PROPELLER
Drive| DIRECT



Fan Motor

| Type| DIRECT CURRENT
Index of protection (IP)| 24
Insulation Grade| E
Running Current (Rated)| A| 0.61
Power Consumption (Rated)| W| 46
Motor Output| W| 26
Poles| 8


Compressor

| Type| HERMETIC SWING
Model| 1YC23AUXDA
Oil type| DAPHNE FVC50K
Oil amount| oz (cm 3 )| 12.4 (375)
Heat Exchanger Type| FIN TUBE
Dimensions (H x W x D)| inch (mm)| 21-11/16 x 26-1/2 x 11-3/16 (550 x 675 x 284)
Packaged Dimensions (H x W x D)| inch (mm)| 24-1/64 x 31-3/8 x 15-1/8 (610 x 801 x 384)
Weight| lbs (kg)| 62 (28)
Gross Weight| lbs (kg)| 68 (31)
Document No.| 3D143595A

  1. ALL UNITS ARE BEING TESTED ACCORDING TO AHRI 210/240 STANDARD.
  2. ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
COOLING HEATING
INDOOR: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB) INDOOR: 70°FDB (21.1°CDB)
OUTDOOR: 95°FDB (35°CDB) OUTDOOR: 47°FDB (8.3°CDB) / 43°FWB (6.1°CWB)

MODEL

| INDOOR UNIT| FTXNG18A
---|---|---
OUTDOOR UNIT| RXNG18A

Cooling                                            Heating

|
Rated Capacity (Min. ~ Max.)| kW| 5.27 (1.96 – 5.86)| 5.24 (1.70 – 6.60)
Btu/h| 18000 (6700 – 20000)| 17900 (5800 – 22500)
Moisture Removal| gal/h| 0.41
Rated Running Current| A| 7.53| 6.98
Rated Power Consumption| W| 1714| 1590
EER2| Btu/h/W| 10.5| N/A
SEER2| 18.0| N/A
COP| W/W| N/A| 3.30
HSPF2| N/A| 8.5
Power Factor (Rated)| N/A
Piping Connections| Liquid| inch (mm)| 1/4” (6.35)
Gas| inch (mm)| 1/2” (12.70)
Refrigerant| Type| R410A
Charge| lbs (kg)| 3.20 (1.45)
Max. Interunit Piping Length| ft (m)| 98-1/2 (30)
Max. Interunit Height Difference| ft (m)| 32-13/16 (10)
Chargeless| ft (m)| 32-13/16 (10)
Amount of Additional Charge of Refrigerant| oz/ft (g/m)| 0.21 (20)
Drawing No.| 3D143694C
INDOOR UNIT| FTXNG18A
Front Panel Colour| WHITE

Airflow Rate

| Turbo| CFM| 754
High| CFM| 716
Medium| CFM| 605
Low| CFM| 467
Quiet| CFM| 395
Sound Pressure Level (H/M/L/Q)| dBA| 48/43/37/33| 46/41/36/33

Fan

| Type| CROSS FLOW
Drive| DIRECT
Speed| 3 STEPS, QUIET, AUTO, TURBO

Fan Motor

| Type| DIRECT CURRENT
Motor Output| W| 39
Running Current (Rated)| A| 0.17
Power Consumption (Rated)| W| 54
Air Direction Control| UP, DOWN, LEFT, RIGHT
Air Filter| CATECHIN
Dimensions (H x W x D)| inch (mm)| 11-11/16 x 39-9/16 x 10-3/4 (297 x 990 x 273)
Packaged Dimensions (H x W x D)| inch (mm)| 14-1/4 x 42-1/4 x 14-1/8 (362 x 1073 x 358)
Weight| lbs (kg)| 31 (14)
Gross Weight| lbs (kg)| 36 (16.5)
Condensate Drain Size| inch (mm)| 5/8 (16)
Document No.| 3D143550B
OUTDOOR UNIT| RXNG18A
Casing Colour| IVORY WHITE
Airflow Rate| High| CFM| 1987| 1952
Sound Pressure Level| dBA| 53
Fan| Type| PROPELLER
Drive| DIRECT

Fan Motor

| Type| DIRECT CURRENT
Index of protection (IP)| 23
Insulation Grade| E
Running Current (Rated)| A| 1.30
Power Consumption (Rated)| W| 85
Motor Output| W| 55
Poles| 8

Compressor

| Type| HERMETIC SWING
Model| 2Y147AKCX2A
Oil type| DAPHNE FVC50K
Oil amount| oz (cm 3 )| 21.5 (650)
Heat Exchanger Type| FIN TUBE
Dimensions (H x W x D)| inch (mm)| 27-13/32 x 36-5/8 x 13-13/16 (696 x 930 x 351)
Packaged Dimensions (H x W x D)| inch (mm)| 29-7/8 x 42-3/8 x 18-7/8 (760 x 1075 x 480)
Weight| lbs (kg)| 97 (44)
Gross Weight| lbs (kg)| 106 (48)
Document No.| 3D143595A

  1. ALL UNITS ARE BEING TESTED ACCORDING TO AHRI 210/240 STANDARD.
  2. ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
COOLING HEATING
INDOOR: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB) INDOOR: 70°FDB (21.1°CDB)
OUTDOOR: 95°FDB (35°CDB) OUTDOOR: 47°FDB (8.3°CDB) / 43°FWB (6.1°CWB)

Dimensions

Indoor Unit

Model : FTXNG09/12AGoodman R410A FTXNG-A Series Inverter Split Unit Air
Conditioner Wall Mounted-fig-1 Model : FTXNG18AGoodman R410A FTXNG-A
Series Inverter Split Unit Air Conditioner Wall Mounted-
fig-2

Outdoor Unit

Model : RXNG09/12AGoodman R410A FTXNG-A Series Inverter Split Unit Air
Conditioner Wall Mounted-fig-3

Model : RXNG18AGoodman R410A FTXNG-A Series Inverter Split Unit Air
Conditioner Wall Mounted-fig-4

**Wiring Diagrams

**

**Indoor Unit

**

Model : FTXNG-AGoodman R410A FTXNG-A Series Inverter Split Unit Air
Conditioner Wall Mounted-fig-5

Outdoor Unit

Model : RXNG09/12AGoodman R410A FTXNG-A Series Inverter Split Unit Air
Conditioner Wall Mounted-fig-6

Model : RXNG18AGoodman R410A FTXNG-A Series Inverter Split Unit Air
Conditioner Wall Mounted-fig-7

Piping Diagrams

Indoor Unit

Model: FTXNG09AGoodman R410A FTXNG-A Series Inverter Split Unit Air
Conditioner Wall Mounted-fig-8 Model : FTXNG12A Goodman R410A FTXNG-A
Series Inverter Split Unit Air Conditioner Wall Mounted-
fig-9

Model : FTXNG18AGoodman R410A FTXNG-A Series Inverter Split Unit Air
Conditioner Wall Mounted-fig-10

Outdoor Unit

Model: RXNG09AGoodman R410A FTXNG-A Series Inverter Split Unit Air
Conditioner Wall Mounted-fig-11 Model : RXNG12AGoodman R410A FTXNG-A
Series Inverter Split Unit Air Conditioner Wall Mounted-
fig-12Model : RXNG18AGoodman R410A FTXNG-A Series Inverter Split Unit Air Conditioner Wall
Mounted-fig-13

Capacity Tables

Model : FTXNG09A – RXNG09AGoodman R410A FTXNG-A Series Inverter Split
Unit Air Conditioner Wall Mounted-14

Model : FTXNG12A – RXNG12AGoodman R410A FTXNG-A Series Inverter Split
Unit Air Conditioner Wall Mounted-15 Model : FTXNG18A – RXNG18AGoodman
R410A FTXNG-A Series Inverter Split Unit Air Conditioner Wall
Mounted-16

Capacity correction factor by the length of refrigerant pipingGoodman
R410A FTXNG-A Series Inverter Split Unit Air Conditioner Wall Mounted-
fig-17 Goodman
R410A FTXNG-A Series Inverter Split Unit Air Conditioner Wall Mounted-
fig-18

Notes:

  1. 1.——– represents the capacity correction factor for the capacity when additional refrigerant of the proper quantity is charged.

  2. The correction ratio remains the same whether the outdoor unit is to be installed above or below the unit.

  3. Calculation method for capacity
    Capacity = capacity obtained from engineering data x capacity correction factor

  4. The actual unit piping length shall not exceed the maximum piping length shown on the table.

Operation  Limit

Model : RXNG-AGoodman R410A FTXNG-A Series Inverter Split Unit Air
Conditioner Wall Mounted-fig-19

Sound Level

Measuring LocationGoodman R410A FTXNG-A Series Inverter Split Unit Air
Conditioner Wall Mounted-fig-20

Notes:

  1. Operation sound is measured in an anechoic chamber.

Sound Pressure Level


Model

| ****

Speed

| 1/1 Octave A-weighted Sound Pressure Level (dB, ref 20µPa)| Overall (dBA)| Noise Criteria
---|---|---|---|---
63Hz| 125Hz| 250Hz| 500Hz| 1kHz| 2kHz| 4kHz| 8kHz




FTXNG09A

(Cooling)

| High| 54| 43| 41| 39| 39| 35| 26| 15| 43| 38
Med| 45| 35| 36| 33| 32| 26| 17| 12| 36| 31
Low| 37| 28| 30| 27| 25| 19| 12| 10| 29| 23
Quiet| 25| 19| 20| 16| 13| 10| 8| 9| 19| 0

NC CurveGoodman R410A FTXNG-A Series Inverter Split Unit Air Conditioner
Wall Mounted-fig-21 Sound Pressure Level


Model

| ****

Speed

| 1/1 Octave A-weighted Sound Pressure Level (dB, ref 20µPa)| Overall (dBA)| Noise Criteria
---|---|---|---|---
63Hz| 125Hz| 250Hz| 500Hz| 1kHz| 2kHz| 4kHz| 8kHz




FTXNG09A

(Heating)

| High| 49| 37| 39| 37| 40| 34| 26| 15| 42| 39
Med| 36| 29| 37| 33| 31| 24| 13| 11| 35| 30
Low| 30| 23| 32| 26| 24| 16| 12| 10| 29| 22
Quiet| 23| 21| 29| 23| 19| 11| 11| 9| 25| 17

NC CurveGoodman R410A FTXNG-A Series Inverter Split Unit Air Conditioner
Wall Mounted-fig-22 Sound Pressure Level


Model

| ****

Speed

| 1/1 Octave A-weighted Sound Pressure Level (dB, ref 20µPa)| Overall (dBA)| Noise Criteria
---|---|---|---|---
63Hz| 125Hz| 250Hz| 500Hz| 1kHz| 2kHz| 4kHz| 8kHz




FTXNG12A

(Cooling)

| High| 44| 36| 42| 40| 43| 37| 29| 19| 45| 42
Med| 34| 29| 35| 33| 34| 28| 19| 12| 37| 33
Low| 26| 24| 30| 29| 27| 21| 14| 11| 31| 25
Quiet| 17| 19| 18| 16| 13| 11| 10| 9| 19| 0

NC CurveGoodman R410A FTXNG-A Series Inverter Split Unit Air
Conditioner Wall Mounted-fig-23

Sound Pressure Level


Model

| ****

Speed

| 1/1 Octave A-weighted Sound Pressure Level (dB, ref 20µPa)| Overall (dBA)| Noise Criteria
---|---|---|---|---
63Hz| 125Hz| 250Hz| 500Hz| 1kHz| 2kHz| 4kHz| 8kHz




FTXNG12A

(Heating)

| High| 47| 36| 40| 38| 41| 34| 23| 12| 43| 40
Med| 39| 29| 37| 33| 32| 24| 14| 11| 36| 31
Low| 29| 25| 32| 28| 26| 17| 12| 11| 30| 24
Quiet| 28| 24| 29| 25| 20| 12| 10| 10| 26| 19

NC CurveGoodman R410A FTXNG-A Series Inverter Split Unit Air Conditioner
Wall Mounted-fig-24

Sound Pressure Level


Model

| ****

Speed

| 1/1 Octave A-weighted Sound Pressure Level (dB, ref 20µPa)| Overall (dBA)| Noise Criteria
---|---|---|---|---
63Hz| 125Hz| 250Hz| 500Hz| 1kHz| 2kHz| 4kHz| 8kHz




FTXNG18A

(Cooling)

| High| 51| 41| 45| 43| 44| 42| 35| 25| 48| 43
Med| 41| 35| 41| 39| 39| 37| 29| 18| 43| 38
Low| 34| 30| 37| 34| 33| 30| 21| 13| 37| 32
Quiet| 30| 28| 34| 31| 28| 23| 13| 10| 33| 26

NC CurveGoodman R410A FTXNG-A Series Inverter Split Unit Air Conditioner
Wall Mounted-fig-25

Sound Pressure Level


Model

| ****

Speed

| 1/1 Octave A-weighted Sound Pressure Level (dB, ref 20µPa)| Overall (dBA)| Noise Criteria
---|---|---|---|---
63Hz| 125Hz| 250Hz| 500Hz| 1kHz| 2kHz| 4kHz| 8kHz




FTXNG18A

(Heating)

| High| 52| 40| 43| 42| 42| 39| 30| 16| 46| 41
Med| 45| 35| 39| 38| 37| 34| 24| 12| 41| 36
Low| 38| 31| 38| 34| 32| 25| 14| 11| 36| 31
Quiet| 37| 29| 35| 31| 29| 23| 12| 10| 33| 28

NC Curve

Goodman R410A FTXNG-A Series Inverter Split Unit Air Conditioner Wall
Mounted-fig-26

Electric Characteristic

Unit Combination Power Supply COMP OFM IFM
Indoor Unit Outdoor Unit Hz-Volts Voltage Range MCA
kW MOC

FTXNG09A

|

RXNG09A

| 60Hz-208V| MAX. 60Hz 253V MIN. 60Hz 187V|

12.35

|

15

|

88

|

4.34

|

0.026

|

0.60

|

0.022

|

0.35

60Hz-230V

FTXNG12A

|

RXNG12A

| 60Hz-208V| MAX. 60Hz 253V MIN. 60Hz 187V|

12.40

|

15

|

96

|

5.57

|

0.026

|

0.61

|

0.022

|

0.40

60Hz-230V

FTXNG18A

|

RXNG18A

| 60Hz-208V| MAX. 60Hz 253V MIN. 60Hz 187V|

16.55

|

20

|

90

|

8.17

|

0.055

|

1.30

|

0.039

|

0.55

60Hz-230V

Symbols:

  • MCA: Minimum Circuit Amps (A)
  • MOP: Maximum Overcurrent Protection (A)
  • COMP: Compressor
  • RHz: Rated Operating Frequency (Hz)
  • A: Compressor Input Current (A)
  • OFM: Outdoor Fan Motor
  • IFM: Indoor Fan Motor
  • kW: Fan Motor Rated Output (kW)
  • MOC: Maximum Operating Current (A)

Notes:

  1. RHz is the max frequency that comes in cooling operation and heating operation.
  2. RLA is the max current that comes in cooling operatio and heating operation.3
  3. Maximum allowable voltage that is unbalance between phases is 2%.
  4. Select wire size based on the larger value of MCA.
  5. Use circuit breaker instead of fuse

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Goodman User Manuals

Related Manuals