SDC GL160 Electrochemical Gate Lock Installation Guide
- June 6, 2024
- SDC
Table of Contents
**SDC GL160 Electrochemical Gate Lock Installation Guide
**
Available Models
GL 160AI: Fail-Safe
GL 260AH: Fail-Secure
GL 163AI: Fail-Safe, Built in Key Switch
GL 263AH: Fail-Secure, Built in Key Switch
GL 260MRA: Fail-Secure, Mechanical Release
Lock Operation
The Lock has an adjustable automatic relock switch (ARS standard) that keeps the bolt retracted until the gate is in a closed position. A Bolt Position Switch (BPS, optional) monitors the lock and unlock position of the bolt. A gate position switch (DPS, optional) is also available to monitor whether a gate is opened or closed.
Specifications
Dimensions: W 5″ x H 6-1/8″ x D 2″
Material: Steel
Finish: Black
Solenoid: Continuous Duty
Bolt Throw: 5/8″
Bolt Dia:: 5/8″
Dual Voltage: 900mA @ 12 VDC, 450mA @ 24 VDC
CAUSTION: DO NO INSTALL LOCKING TONGUE ONTO LOCK UNTIL WIRING IS COMPLETE
GL160A & GL260A – GATE LOCK MOUNTING
Use the lock housing as a template to mark the mounting holes onto the post.
If the wiring will go through the post remove cover and mark the wiring hole
before mounting. Use a 3/8″ drill size to drill out all holes. Be sure to shim
between the mounting brackets as required if the gate post is less than 3″.
See illustration 1 & 2.
Determine the hand of gate and install the switches accordingly. See
Illustration 3. The Illustration below gives an example of a LH swing and or a
RH sliding gate install. To reverse the handing swap the position of the ARS
and centering assembly to the opposite side of lock.
Before mounting the locking tongue verify that it is properly aligned within
the gate lock opening. The locking tongue should be centered with the bolt and
make contact with centering assembly and ARS. Once verified mark the mounting
holes and drill use 3/8″ drill size for all holes. See illustration 4.
Refer to page 4 of instructions for wiring information.
Test operation to verify that its functioning properly and re install cover..
-
Illustration 1
-
Illustration 2
-
Illustration 3
-
Illustration 4
-
Right Hand Sliding Gate Or LH Swing Gate shown
GL163A & GL263A – BUILT IN KEY SWITCH
Install key cylinder per notes below
- a) Cylinder must be 1-1/8” mortise type with standard tailpiece. See illustrations 5
- b) Remove key and invert the tailpiece. See illustration 6.
Refer to page 4 of instructions for wiring information.
-
Illustration 5
-
Illustration 6
Note position of mortise cylinder & tailpiece relative to switch. Tailpiece must point up & depress switch button at all times with key removed.
GL260MRA – MECHANICAL RELEASE
Install key cylinder per notes below
- a) Cylinder must be 1-1/8” mortise type with standard tailpiece. See illustrations 7
- b) Tailpiece must contact retraction arm as shown in View A-A; See illustration 8.
Refer to page 4 of instructions for wiring.
-
Illustration 7
-
Illustration 8
WIRING REFERENCE
- GL160A Typical wiring
- Auto Relock switch wiring shown with tongue engaged inside lock
-
GL260A/260MRA Typical wiring
-
GL163A Typical wiring
- Auto Relock switch wiring shown with tongue engaged inside lock
- Key switch wiring shown with tailpiece depressing switch
- GL263A Typical wiring
OPTIONALMONITORING WIRING REFERENCE
-
Illustration 8
-
260 BPS Wiring
Shown when Bolt is retracted
-
160 BPS Wiring
Shown when Bolt is retracted
-
DPS Wiring
WHT = COM
YEL = N/C
ORG = N/O
Shown when tongue is inserted
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>