ergotron DM12-10060-1 Zip 12 Charging Wall Cabinet User Guide
- June 6, 2024
- ERGOTRON
Table of Contents
DM12-10060-1 Zip 12 Charging Wall Cabinet
8VHU
V*XLGH
=LS&KDUJLQJ:DOO&DELQHW
ESPAÑOL
(QJOLVK
)RUWKHODWHVW8VHU,QVWDOODWLRQ*XLGHSOHDVHYLVLWZZZHUJRWURQFRP
(QJOLVK(VSD³RO)UDQ©DLV’HXWVFK1HGHUODQGV,WDOLDQR6YHQVND www.ergotron.com | USA:
1-800-888-8458 | Europe: +31 (0)33-45
45 600 | China: 400-120-3051 | Japan: japansupport@ergotron.com
*UHY)
RI
Hazard Symbols
Symbol
Review
These symbols alert users of a safety condition that demands attention. All users should be able to recognize and understand the significance of the following Safety Hazards if encountered on the product or within the documentation. Children who are not able to recognize and respond appropriately to Safety Alerts should not use this product without adult supervision!
Signal Word
Level of Hazard
NOTE
A NOTE indicates important information that helps you make better use of this product.
CAUTION
A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING
A WARNING indicates either potential for property damage, personal injury, or death.
ELECTRICAL
An Electrical indicates an impending electrical hazard which, if not avoided, may result in personal injury, fire and/or death.
Safety
WARNING: Because surfaces vary widely and the ultimate mounting method is out of Ergotron’s control, it is imperative that you consult with appropriate engineering, architectural or construction professional to ensure that your Ergotron mounting solution is mounted properly to handle applied loads.
CAUTION: Make sure the wall mount bracket is level, flush and snug to the wall surface. DO NOT OVERTIGHTEN THE BOLTS.
< 44.4 lbs. (20.1 kg)
CAUTION: DO NOT EXCEED MAXIMUM LISTED WEIGHT CAPACITY. SERIOUS INJURY OR
PROPERTY DAMAGE MAY OCCUR!
ESPAÑOL
RI
*UHY)
Components
A
1x
1
2
3 4x
B
C
1x
1x
2x
1x
5/32″
D
5x
4x
1/4″-20 x 2″
5x
M6 x 70mm
Tools Needed
Stud Finder
WOOD STUD HOLLOW WALL
Ø 3/16″ (5 mm) Ø 1/2″ (13 mm)
CONCRETE Ø 3/8″ (10 mm)
10mm
1 REMOVE INTERNAL PACKAGING
TEAM LIFT
For Your Safety!
a
b
c
ESPAÑOL
*UHY)
RI
2 MOUNTING CONSIDERATIONS
Space Requirements:
35.3″
(900 mm)
7″ 6″ (152 mm) (178 mm)
3″
(74 mm)
Mounting Holes
When mounting to wood stud, at least one screw in the upper mounting bracket must be installed in a stud (preferably the center hole).
11.8″ 6.5″ (300 mm) (168 mm) 4″ (102 mm)
6″
(151 mm)
32.75″
(831 mm)
35.6″
(905 mm)
ESPAÑOL
62″-68″
(158-173 cm) Recommended Mounting Height Above Floor
Floor
3
WOOD STUD HOLLOW WALL
Individual tablet or chromebook weight: Individual dimensions (including
cover):
< 11.9″ (302 mm)
< 8.5″
(215 mm)
< 3 lbs
(1.36 kg)
< 1″
(25 mm)
CONCRETE
RI
5
8
*UHY)
WOOD STUD HOLLOW WALL
a First Choose a Hole Option: The stud can be located at one of five mounting
holes on the top bracket. While the first option (center hole of bracket) is
recommended, you should consult with a construction professional to confirm
which method is best suited for your particular situation. After you decide on
a Hole Option, follow attachment instructions on the following page.
Hole Option 1
RECOMMENDED
Center Hole in Stud
Hole Option 2
Extreme Left Hole in Stud
Hole Option 3
Extreme Right Hole in Stud
Hole Option 4
Middle Right Hole in Stud
Hole Option 5
Middle Left Hole in Stud
ESPAÑOL
*UHY)
RI
WOOD STUD HOLLOW WALL
b Find stud and draw a mark.
c Put a mark on the stud 62″-68″ (158-173 cm) from floor.
62″-68″ (158-173 cm)
d
e Place template on wall lining up the
Level and secure template
chosen hole with the stud and the
to wall.
mark 62″-68″ (158-173 cm) from floor.
ESPAÑOL
RI
62″-68″ (158-173 cm)
7
*UHY)
WOOD STUD HOLLOW WALL
f 1. Drill the three holes for the top bracket that correspond with the hole
option determined on previous page. 2. Drill the bottom two holes.
NOTE: Use the Ø 3/16″ (5 mm) drill bit when drilling directly into the wood
stud. Use the Ø 1/2″ (13 mm) drill bit when drilling into the hollow wall for
the anchors. Use hollow wall anchors where ever a screw does not get inserted
directly into the wood stud.
62″-68″ (158-173 cm)
WOOD STUD HOLLOW WALL
Ø 3/16″ (5 mm)
10mm
M6 x 70mm
Ø 1/2″ (13 mm)
1x
5/32″
1/4″-20 x 2″
1
2
3
4
g
h Insert anchors then attach bracket to wall according to the hole option determined on previous page. Verify wall bracket is level
before tightening screws.
ESPAÑOL
*UHY)
9
RI
CONCRETE
a Put a mark on the wall 62″-68″ (158-173 cm) from floor.
62″-68″ (158-173 cm)
b Level and secure template to the wall lining up the chosen mounting holes with the mark 62″-68″ (158-173 cm) from floor.
c Drll the top 3 holes, then the bottom two holes.
d
Ø 3/8″ (10 mm)
62″-68″ (158-173 cm)
3-1/8″ (80 mm)
62″-68″ (158-173 cm)
WARNING: Mounting holes must be at least 3-1/8″ (80mm) deep and must be
located within solid concrete, not mortar or covering material. If you drill
into an area of concrete that is not solid, reposition mounting holes until
both anchors can be fully
inserted into solid concrete!
e Insert anchors into holes, then attach mounting bracket. Verify wall
3x
bracket is level before tightening screws.
M6 x 70mm 10mm
ESPAÑOL
WARNING: Anchors that are not fully set in solid concrete will not support the
applied load resulting in an unstable, unsafe condition which could lead to
personal injury and/or property damage. Consult a construction professional if
you have any doubt about what this means in regard to
your particular situation.
5x
RI
9
*UHY)
4 Hang unit onto top bracket.
Warning: 2 people are required to lift this product.
5 a. Remove two screws on left side. Save screws for reattaching cover. b.
Unlock door by turning key 180° clockwise. Open door by turning knob 180°
clockwise.
a
b
6 a. Open door and remove these 3 screws. Save screws for reattaching cover. b. Remove left cover
a
b
ESPAÑOL
*UHY)
RI
7 a. Secure unit to wall by inserting screw through back wall and into bottom right wall anchor. b. Close door, then insert screw through back wall and into bottom left wall anchor.
WOOD STUD HOLLOW WALL
CONCRETE
2x 1/4″-20 x 2″ a
5/32″
2x
a
M6 x 70mm 10mm
b
b
ESPAÑOL
RI
*UHY)
8 a. Plug in all the tablet power cables into the outlets inside. (Customer supplies power cables that come with the devices) b. Route cables through the access holes. c. Open door an pull cables through the access holes.
a
b
ESPAÑOL
c
*UHY)
RI
9
Pull out tablet tray and insert tablet.
NOTE: Tablet should be positioned so power plug is at top or left side.
ESPAÑOL
10 a. Slide cable clip off of tablet slot and route cable through clip, then reattach cable clip. NOTE: Leave enough slack in cable to plug into tablet.
b. Plug tablet cables into tablets. NOTE: When tablet is removed, store unconnected cable in the appropriate tablet slot.
a
b
RI
*UHY)
11 Tie up excess cable with velcro cable ties.
NOTE: Keep cables away from power system components that might get hot during operation.
12 a. Attach left cover with 2 screws saved from removal of cover. b. Open door and attach 3 inside screws saved from removal of left cover
a
b
ESPAÑOL
*UHY)
RI
13 a. Close door and turn lock knob 180° counter clockwise. b. Lock door by turning key 180° counterclockwise.
a
b
14 Plug power cable into bottom power jack and then into wall outlet to start charging.
ESPAÑOL
RI
*UHY)
Tablet Charging
To begin charging the tablets, plug in the power cord.
The power cord is used to turn the power on and off. Charging occurs whenever
the power cord is connected to an outlet.
ESPAÑOL
LED
NOTE: The power cord acts as the connect/disconnect device switching power on and off. The socket outlet shall be installed near the equipment and shall be easily accessible.
Power Indicator Communicates charge status with the following signals:
Light Off On – solid
Description No power to the module. Tablets or Chromebooks are charging.
Specifications
Dimensions 26.4″W x 35.6″H x 5.9″D (669 x 905 x 151 mm)
Weight (w/o equipment) 64.5 lbs (29.3 kg)
Rated weight capacity 44.4 lb (20.1 kg)
Maximum tablet or chromebook size Individual dimensions (including cover):
up to 11.9″H x 8.9″W x 1.0″D (30 x 23 x 2.5 cm) Individual tablet or
chromebook weight:
up to 3 lb (1.4 kg)
Cooling/ventilation One 12V DC continuous operation fan
Shipping dimensions 40.9″ x 28.9″ x 8.4″ (1040 x 735 x 214 mm)
Shipping weight 77 lb (34.9 kg)
Power system Part number DM12-1006-1 DM12-1006-2 DM12-1006-3 DM12-1006-4 DM12-1006-5
Power System Input: 100-120V~, 12A, 50/60 Hz Input: 220-240V~, 8A, 50/60 Hz Input: 220-240V~, 8A, 50/60 Hz Input: 220-240V~, 8A, 50/60 Hz Input: 220-240V~, 8A, 50/60 Hz
Environmental Temperature range: Operating 0° to 30°C (32° to 86°F) Storage
-40° to 60°C (-40° to 140°F) Relative humidity (maximum): Operating 10%90%
(non condensing) Storage 5%95% (non condensing) Altitude (maximum): 2000 m
(6,562 ft)
Compatibility: Tablets and chromebooks
Certification: UL / IEC / EN 62368-1 Audio/Video Information and Communication
Technology Equipment. CAN/CSA C22.2 No. 62368-1-14 ICES-003 Issue 5, Class A
FCC Part 15 Class A RoHS and REACH compliant material used.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: 1) This device may not cause harmful
interference. 2) This device must accept any interference received, including
interference that may cause undesired operation.
CAN ICES-3(A) / NMB-3(A).
UNIVERSAL TABLET WALL STATION 12
Input/Output: 100-240V~, 12A-10A, 50/60 Hz
Ergotron Europe Beeldschermweg 3 3821 AH, Amersfoort The Netherlands
35MR
UL 62368-1 CAN/CSA C22.2 No. 62368-1-14 IEC/EN 62368-1
*UHY)
Product of China
827-345-00
RI
Cleaning and Maintenance
Equipment Electric Safety There are specific risks associated with the use of
equipment having power cables. You must be aware of, and avoid these risks
when this product is located in close proximity to children.
WARNING: Failure to observe the following Electrical Safety notices can result
in fire or death by electric shock.
Electrical cables can be hazardous. Misuse can result in fire or death by
electrical shock. · Double Pole / Neutral Fusing · Inspect power cables
thoroughly before each use. · Do not use cables that are damaged. · Insert the
plug completely into the outlet. · Grasp the plug to remove from the outlet. ·
Do not unplug by pulling on the cable. · Do not use excessive force to make
connections. · Do not plug the cable into an extension cable. · Do not remove,
bend or modify any metal prongs or pins of cable. · Do not drive, drag or
place objects over the cable. · Do not walk on the cable. · Avoid overheating.
Uncoil the cable and do not cover it with any material. · Do not run cable
through doorways, holes in ceilings, walls or floors.
Keep this product away from water. · Do not use when wet. · Do not place this
product in close proximity to flammable liquids or gases.
This product is intended for use only with loading as indicated. Use with
loads greater than indicated may result in instability causing possible
injury.
The power cord acts as the connect/disconnect device switching power on and
off. The socket outlet shall be installed near the equipment and shall be
easily accessible.
CAUTION: Changes or Modifications not expressly approved by Ergotron could
void the user’s authority to operate the equipment.
Use Safety There are specific risks associated with the use of this product
(for charging or storage). You must be aware of, and avoid these risks when
this product is located in close proximity to children.
WARNING: Failure to observe the following Use Safety notices may result in
serious personal injury or equipment damage.
Only Adults should use this product. · Do not allow anyone to climb or hang on
this product. · Do not block the fans and vent openings. To prevent
overheating, leave at least 102 mm (4-inch) clearance around fans and vents.
This product is designed to be used indoors only. · Do not use this product to
store equipment other than what has been noted in this guide. · Do not use
this product to store liquids or cleaning supplies. · Do not place heavy
objects on this product. The maximum weight capacity is 44.4 lbs (20.1 kg).
ESPAÑOL
RI
*UHY)
)RU:DUUDQWYLVLWZZZHUJRWURQFRPZDUUDQW )RU6HUYLFHYLVLWZZZHUJRWURQFRP
)RUORFDOFXVWRPHUFDUHSKRQHQXPEHUVYLVLWKWWSFRQWDFWHUJRWURQFRP
127(:KHQFRQWDFWLQJFXVWRPHUVHUYLFHUHIHUHQFHWKHVHULDOQXPEHU
www.ergotron.com MADE IN CN 12-345-678 1234567-1234
ESPAÑOL
www.ergotron.com | USA: 1-800-888-8458
| Europe: +31 (0)33-45 45 600 | China: 400-120-3051 | Japan:
japansupport@ergotron.com
k(UJRWURQ,QF$OOULJKWVUHVHUYHG
*UHY)
RI
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>