DFx iLeaf 2 Shelf Cooler With Recirc Beer Coolers Instruction Manual

June 13, 2024
DFX

DFx iLeaf 2 Shelf Cooler With Recirc Beer Coolers

Product Information

  • Compressor Running: Indicates that the temperature is too warm or there is a fault in the service. Service is required or the settings mode needs to be accessed.
  • Standby: Press for 2 seconds to place the unit in standby mode for 2 hours. The standby symbol will be displayed on the screen during this period with the words “Standby for 2 hours”.
  • Probe Fault: Indicates a fault with the probe. The calibration value of the probe can be changed.
  • Clean Mode: Activates the clean mode function.
  • Electrical Input Voltage: 230V AC +/-10%
  • Inrush Current: 80A
  • Holding Current: 16A (resistive)
  • Connections: Live, Neutral, Compressor Live
  • Mechanical Dimensions: H34 W76 D88 with cover (mm)
  • Cut Out: W71 H29 (mm)
  • Environmental: Front IP65, Rear IP64 using rear cover. Operating Temperature: 0 to 50°C. Storage Temperature: -20 to 70°C. Relative Humidity: 0% to 90% non-condensing
  • Material Parts: Polycarbonate body and lens, clips POM. Gasket: Neoprene Rubber
  • Design & Manufacture: Designed & Manufactured to ISO9001:2015 / 14001. CE Compliant. RoHS Compliant. MTBF 5 years
  • Probe Accuracy: Calibrated probe +/-0.2°C @ 0°C
  • Configuration of Settings: Press for 3 seconds and release to configure set point and hysteresis. Press / to adjust the values and proceed. Press to reset the control to its default settings.
  • Connection Details: Isolate the cooler unit from all power supplies before carrying out installation. Remove the plug from the wall. Protect the i-Leaf controller from adverse conditions. Do not drop or expose the i-Leaf controller to solvents. Clean the exterior of the i-Leaf controller by removing dust and dirt with a dry cloth. Do not use abrasives or chemical cleaning agents.

Instructions

Changing calibration value (probe match)
Power up unit pressing to set probe calibratior then release to display the cal value i.e. 285. Use and to change value, ****to exit and store the new value. NB The probe calibration value can be found on the probe.

Clean Mode
Press **for 2 sec to place in standby for 2 hours the standby symbol will be display on the screen during this period with the words CLn**.

Operating Instructions

Electrical
Input Voltage: 230V ac +/-10%
Inrush Current: 80A
Holding Current: 16A (resistive)
Connections: Live, Neutral, Compressor Live

Mechanical
Dimensions: H34 x W76 x D88 with cover (mm)
Cut Out: W71 x H29 (mm)

Environmental
Front IP65, Rear IP64 using rear cover
Operating Temperature: 0° to 50°C
Storage Temperature: -20° to 70°C
Relative Humidity: 0% to 90% non-condensing

Material
Parts: Polycarbonate body and lens, clips POM
Gasket: Neoprene Rubber

Design & Manufacture
Designed & Manufactured to IS09001:2015 / 14001
CE Compliant
RoHS Compliant
MTBF 5 years

Probe Accuracy
Calibrated probe +/-0.2 Deg C @ 0 Deg C.

Configuration of settings

Press ****for 3 sec and release to configure

  • Set point: press / to adjust, to proceed.
  • Hysteresis: press / to adjust, to proceed.
  • Reset: Press to reset the control to its default settings, donE will be display when completed

The controller will automatically revert to displaying the current temperature after 30 seconds.
Any changes to settings that have been made will be lost.

Connection details

WARNING: ISOLATE THE COOLER UNIT FROM ALL POWER SUPPLIES BEFORE CARRYING OUT INSTALLATION. REMOVE THE PLUG FROM THE WALL.

  • Protect the i-Leaf controller from adverse conditions.
  • Do not drop the i-Leaf controller.
  • Do not expose the i-Leaf controller to solvents.
  • Clean the exterior of the i-Leaf controller by removing dust and dirt with a dry cloth.
  • Do not use abrasives or chemical cleaning agents to clean the i-Leaf controller.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

DFX User Manuals

Related Manuals