PLP-60 Series 60W Single Output LED Power Supply Instruction Manual

June 13, 2024
PLP

60W Single Output LED Power Supply
PLP-60 seriesPLP-60 Series 60W Single Output LED Power
SupplyPLP-60 Series 60W Single Output LED Power
Supply - icon

GTINCODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Features

  • Universal AC input / Full range
  • Protections: Short circuit / Over current/ Over voltage
  • Built-in active PFC function
  • Cooling by free air convection
  • Class 2 power unit
  • Output current level adjustable
  • 100% full load burn-n test
  • High reliability
  • Suitable for built-in applications of LED lighting
  • 2 years warranty

SPECIFICATION

MODEL PLP-60-12 PLP-60-24 PLP-60-48
OUTPUT DC VOLTAGE 12V 24V
CONSTANT CURRENT REGION Note.5 9 ~ 12V 18 ~ 24V 36 ~ 48V
RATED CURRENT 5A 2.5A 1.3A
CURRENT RANGE 0 ~ 5A 0 ~ 2.5A 0 ~ 1.3A
RATED POWER 60W 60W 62.4W
RIPPLE & NOISE (max.) Note.2 4.5Vp-p 4.5Vp-p 4.8Vp-p
CURRENT ADJ. RANGE 3.75 ~ 5A 1.875 ~ 2.5A 0.975 ~ 1.3A
VOLTAGE TOLERANCE Note.3 ±10%
LINE REGULATION ±3.0%
LOAD REGULATION ±5.0%
SETUP TIME 500ms / 230VAC  1200ms / 115VAC at full load
INPUT VOLTAGE RANGE Note.4 90 ~ 264VAC        127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF≧0.9 at 75 ~ 100% load, 115VAC / 230VAC
TOTAL HARMONIC DISTORTION THD< 20% when output loading≥75% at

115VAC/230VAC input
EFFICIENCY (Typ.)| 84%| 88%| 89%
AC CURRENT (Typ.)| 0.8A/115VAC 0.4A/230VAC
INRUSH CURRENT (max.)| COLD START 35A(width=55μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 32units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 240VAC
PROTECTION| OVER CURRENT Note.5| 100 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT| Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 15 ~ 18V| 28 ~ 35V| 57 ~ 63V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC| SAFETY STANDARDS| GB19510.1,GB19510.14,UL8750, TUV BS EN/EN61347-1, BS EN/EN61347-2-13, CSA C22.2 No. 250.0-08(except for 48V),

EAC TP TC 004 approved ; design refer to UL60950-1

WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to GB17625,GB17743, BS EN/EN55015, BS EN/EN61000-3-2 Class C(≧75% load); BS EN/EN61000-3-3,EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035,BS EN/EN61547, light industry level, EAC TP TC 020
OTHERS| MTBF| 5065.8K hrs min. Telcordia SR-332 (Bell core) ; 583.3K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 101.650.829.6mm (LWH)
PACKING| 0.16Kg; 96pcs/16.4Kg/0.89CUFT
NOTE| 1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.  Tolerance : includes set up tolerance, line regulation and load regulation.
4.  Derating may be needed under low input voltage. Please check the static characteristics for more details.
5.  Please refer to “Drilling METHODS OF LED MODULE”.
6.  Heat sink HS1,HS2 can not be shorted.
7.  Heat sink HS1 must have safety isolation distance with system case.
8.  The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9.  Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
10.  To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
11.  The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm *360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMl testing of component power supplies. (as available on http://www.meanwell.com)
12.  PLP-60-12 is used for any light source that exempt from the ErP-Directive (EU) 2019/2020 requirement, for example this model could be use for signaling products(including, but not limited to road-, railway-, marineorair traffic- signaling , traffic control or airfield lamps) .
c※ omp. product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:PLP-60-SPEC  2022-08-04

Mechanical Specification

PLP-60 Series 60W Single Output LED Power Supply - Mechanical
Specification

  1. HS1 HS2 canto be shorted
  2. HS1 must have safety isolation distance with system case.
  3. M1 is safety ground. For better EMC performance, Please secure an electrical ‘connection between M1,M2,M3,and chassis grounding

AC Input Connector (CN1) : JST B3P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 AC/L JST VHR or equivalent JST SVH-21T-P1.1 or equivalent
2 No Pin
3 AC/N

DC Output Connector (CN2): JST B2P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 +V JST VHR or equivalent JST SVH-21T-P1.1 or equivalent
2 -V

Block Diagram

PLP-60 Series 60W Single Output LED Power Supply - Block
Diagram

Derating Curve

Static Characteristics

Power Factor Characteristic

PLP-60 Series 60W Single Output LED Power Supply - Power
Factor

EFFICIENCY vs LOAD (48V Model)
PLP-60 series possess superior working efficiency that upTOP 89% can be reached field applications.

PLP-60 Series 60W Single Output LED Power Supply - Power
Factor1

DRIVING METHODS OF LED MODULE
This LED power supply is suggested to working constant current mode area (CC)to drive the LEDs.