You will need a crosshead screwdriver/drill bit to install this system.
- Install felt spacers if using V2 or Centurion/Senator packs. Lay underlay by BS 5534. Before fixing the top tiling batten, fix a ridge batten bracket to the top of each truss using 25mm aluminium nails on either side. The brackets should be fixed such that 20mm penetration into the ridge batten is achievable when fixing the ridge tiles. Fix the top tiling batten.
- Locate a 25x50mm ridge batten into the ridge batten brackets and fix using 20mm nails on either side. Additional ridge battens should be spliced diagonally over a ridge batten bracket.
- Lay roof tiles by BS 5534.
- Snap together 3 top fillers to form a track for either side of the ridge. Locate a nail hole block end ridge tile into the tracks centrally over the ridge line. The top fillers must be positioned with the smaller ventilation voids on the outside of the ridge tile.
- Place a ridge seal under the block end ridge and locate into the channels of the top fillers.
- Secure the block end ridge using 2 x 80mm screws, washers and grommets provided.
- Continue fixing nail hole ridge tiles, top fillers and ridge seals along the ridge. If cutting is necessary to maintain the aesthetics of the ridge line, the block end ridge must not be cut. Ridge tiles must not be cut to less than half of their original length. All ridge tiles must be twice fixed with screws supplied (re-drill nail holes if necessary). At the verge, trim the last top fillers and fix the block end ridge tile as described in step 6 to finish the ridge line.
Specifications
Component| PAN8 Vented Ridge Pack (6m) (P8T5)| V2 Vented Ridge Pack (3m)
(V2T5)| Centurion/Senator Vented Ridge Pack (3m) (CST5)
---|---|---|---
Ridge Batten Brackets| 10 no.| 6 no.| 6 no.
25mm Aluminium Nails| 40 no.| 24 no.| 24 no.
Top Filler| 34 no. PAN8| 30 no. V2| 30 no. Centurion/Senator
80mm S/S Screws, Rubber Washers & Grommets| 26 no.| 14 no.| 14 no.
Ridge Seals| 13 no.| 7 no.| 7 no.
Duo-pitch Felt Spacers| N/A| 6 no.| 6 no.
- Colours available: Grey, Rustic.
- Conforms to the requirements of BS:8612
- Plastic Type: Polypropylene
Fixing installation examples
- Correct: Screw with washer and grommet not over or under-tightened.
- Incorrect: Over-tightened, under-tightened, or incorrect assembly of screw, washer, and grommet.
For further help and advice contact Technical on 01525 244900 or email Roofing.Technical@Ibstock.co.uk
FAQ
- Who do I contact for further help and advice?
- You can contact Technical on 01525 244900 or email Roofing.Technical@Ibstock.co.uk.
What tools are required for the installation?
A cross-head screwdriver/drill bit is required for the installation process.
What are the specifications of the Profile Tile Vented Ridge Pack?
It provides a 5000mm2/linear metre Free Vent Area and conforms to the requirements of BS 8612.
Are there any specific colour options available for the vented ridge packs?
Yes, the colours available are Grey and Rustic.
What type of plastic is used for the components?
The plastic type used is Polypropylene.
INSTALLATION GUIDE
INSTALLATION GUIDE – RIDGE DETAILING
- Install felt spacers if using V2 or Centurion/Senator packs (Picture 1). Lay underlay under BS 5534. Before fixing the top tiling batten, fix a ridge batten bracket to the top of each truss using 25mm aluminium nails on either side (Picture 2). The brackets should be fixed such that 20mm penetration into the ridge batten is acheivable when fixing the ridge tiles. Fix the top tiling batten.
- Locate a 25x50mm ridge batten into the ridge batten brackets and fix using 20mm nails on either side. Additional ridge battens should be spliced diagonally over a ridge batten bracket (Picture 3).
- Lay roof tiles in accordance with BS 5534.
- Snap together 3 top fillers to form a track for either side of the ridge. Locate a nailhole block end ridge tile into the tracks centrally over the ridge line. The top fillers must be positioned with the smaller ventilation voids on the outside of the ridge tile (Picture 4).
- Place a ridge seal under the block end ridge and locate into the channels of the top fillers (Picture 5).
- Secure the block end ridge using 2 x 80mm screws, washers and grommets provided.
- Continue fixing nail hole ridge tiles, top fillers and ridge seals along the ridge. If cutting is necessary to maintain the aesthetics of the ridge line, the block end ridge must not be cut. Ridge tiles must not be cut to less than half of their original length. All ridge tiles must be twice fixed with screws supplied (re-drill nail holes if necessary). At the verge, trim the last top fillers and fix the block end ridge tile as described in step 6 to finish the ridge line (Picture 6).
Profile Tile Vented Ridge Pack 6m
- Providing 5000mm2/linear metre Free Vent Area Conforms to the requirements of BS 8612
- You will need a crosshead screwdriver/drill bit to install this system.
PAN8 Vented Ridge Pack (6m) (P8T5)
- A) 10 no. Ridge Batten Brackets
- B) 40 no. 25mm Aluminium Nails
- C) 34 no. Top Filler PAN8
- D) 26 no. 80mm S/S Screws, Rubber Washers & Grommets
- E) 13 no. Ridge Seals
Colours available: Grey, Rustic.
V2 Vented Ridge Pack (3m) (V2T5)
- A) 6 no. Ridge Batten Brackets
- B) 24 no. 25mm Aluminium Nails
- C) 30 no. Top Filler V2
- D) 14 no. 80mm S/S Screws, Rubber Washers & Grommets
- E) 7 no. Ridge Seals
- F) 6 no. Duo-pitch Felt Spacers
Colours available: Grey, Rustic.
Centurion/Senator Vented Ridge Pack (3m) (CST5)
- A) 6 no. Ridge Batten Brackets
- B) 24 no. 25mm Aluminium Nails
- C) 30 no. Top Filler Centurion/Senator
- D) 14 no. 80mm S/S Screws, Rubber Washers & Grommets
- E) 7 no. Ridge Seals
- F) 6 no. Duo-pitch Felt Spacers
Colours available: Grey, Rustic.
- Conforms to the requirements of BS:8612
- Plastic Type: Polypropylene
Fixings should be assembled as shown below
- Screw
- Rubber Washer
- Grommet
Fixing installation examples
CONTACT
- For further help and advice contact Technical on 01525 244900 or email Roofing.Technical@Ibstock.co.uk