INSTALLATION GUIDE – VENTILATION DETAILING SL8, PAN8 & V2 Air/Soil Vent Kit
Providing 12275mm2
Free Vent Area
WE ARE
Roofing and more.

 SL8 Air Soil Vent Kit

Minimum spacing 600mm between vent tiles in any direction

  1. Ensure that the tiles are laid at the correct headlap (detailed overleaf). Mark on the underlay the location of the centre of the vent tile spigot (Picture 1).
  2. Cut horizontal and vertical lines to form an opening to accommodate the flexi-pipe through the underlay. Fold up underlay wings as shown (Picture 2).
  3. Position the felt wier under the tiling batten directly above the opening and mark on the underlay the edges of the felt wier (Picture 3).
  4. Cut a horizontal line between the marked edges. Insert the felt weir into the horizontal cut and rest the bottom edge on the batten below (Picture 4).
  5. Secure the flexi-pipe to the vent tile spigot using the jubilee clip provided. (Soil Vent only)
  6. Insert the flexi-pipe into he opening ensuring that the underlay wings are not pushed back into the roof space (Picture 5)
  7. Push the remainder of the flexi-pipe into the opening and ensure that the Lo-Vent sits neatly in place. Nail vent tile into place and secure using one tile clip in accordance with BS 5534.

Air Flow Resistance Performance

| 15 Litres/sec| 30 Litres/sec| 60 Litres/sec
---|---|---|---
SL8| 3 pascals| 10.1 pascals| 31.1 pascals
 PAN8| 3 pascals| 10.1 pascals| 31.1 pascals
V2| 18.5 pascals| 69.5 pascals| 278 pascals

SL8 Vent Components

SL8 Air Vent (SLIV) SL8 Soil Vent (SLSV)

A) SL8 Vent Terminal
B) Felt Weir| A) SL8 Vent Terminal
B) Felt Weir
C) 100mm-160mm Flexi Pipe
D) Jubilee Clips

Colours: Red, Brown, Grey.

SL8 Gauge Headlap
Min Gauge 320mm 100mm
Max Gauge 345mm 75mm

PAN8 Vent Components

PAN8 Air Vent (P8IV) PAN8 Soil Vent (P8SV)

A) PAN8 Vent Terminal
B) Felt Weir| A) PAN8 Vent Terminal
B) Felt Weir
C) 100mm-160mm Flexi Pipe
D) Jubilee Clips

Colours: Red, Brown, Grey.

PAN8 Gauge Headlap
Min Gauge 320mm 100mm
Max Gauge 345mm 75mm

V2 Vent Components

V2 Air Vent (V2IV) V2 Soil Vent (V2IS)

A) V2 Vent Terminal
B) Felt Weir| A) V2 Vent Terminal
B) Felt Weir
C) 100mm-160mm Flexi Pipe
D) Jubilee Clips

Colours: Red, Brown, Grey, Rustic.

V2 Gauge Headlap
Min Gauge 285mm 100mm
Max Gauge 310mm 75mm

For further help and advice contact Technical on 01525 244900 or email Roofing.Technical@Ibstock.co.uk