KOHLER Mira Sport Shower Fittings L16J User Manual

June 6, 2024
Kohler

KOHLER logo Mira Sport Shower Fittings (L16J)
Installation and
User Guide

These instructions must be left with the user

GENERAL

  1. Make sure that the shower fittings are installed by a competent installer.

  2. Installations must comply with Water Regulations (Bye-Laws, Scotland), and any other Local Regulations and Building Regulations in force at the time of installation.

  3. The shower fittings should be positioned at a convenient height for all the family. Position the fittings to spray across rather than towards the opening of the cubicle and also away from the shower control. Avoid layouts where the shower hose will be sharply kinked. This may reduce the life of the hose.

  4. Do not fit any form of flow control in the outlet pipework if the shower fittings are installed in conjunction with a product that requires the fittings to act as a vent (e.g. an electric shower).

  5. Special consideration should be given to the fixing arrangements when installing onto a dry lined, stud partition, shower cubicle, or laminated panel wall structure. Installers may wish to obtain alternative proprietary cavity fixings, or choose other options, however, these methods of fixing are beyond the scope of this guide.
    Note! An alternative Slide Bar Support Pack is available. Contact our Customer Services team for more details.

  6. A hose retaining ring (integrated into the soap dish) is supplied to prevent the showerhead from dropping below the spill-over level of the bath or shower, which could lead to contamination from the back-siphonage.
    The position of the shower and shower fittings must provide a minimum gap of 25 mm between the showerhead and the spill-over level of any bath, shower tray, or basin and 30 mm between the showerhead and the spill-over level of any toilet or bidet.

KOHLER Mira Sport Shower Fittings L16J - toilet or
bidet

Hose Retaining Ring (Integrated into soap dish) fitted and shower fittings fixed at a
suitable height preventing dirty water backflow

SPECIFICATION – PRESSURES

Minimum maintained pressure: 0.1 bar (10 kPa)
Maximum maintained pressure: 5.0 bar (500 kPa)

CLEANING

Cleaning
Many household cleaners contain abrasives and chemical substances, and should not be used for cleaning plated or plastic fittings. These finishes should be cleaned with a mild washing-up detergent or soap solution, and then wiped dry using a soft cloth.

INSTALLATION

  1. We recommend that the slide bar is installed with the ends flush. Mark the wall fixing positions and drill two holes to suit the wall fixings.
    Caution! Do not drill into cables or pipes in the wall.
    Note! For a new installation, optimum fixing centers are 635 mm. Replacement installation fixing centers are 635 mm maximum.

  2. Install the wall plugs and the mounting brackets and secure them with the wall screws.
    Note! Check for vertical alignment before tightening. The mounting brackets are slotted to aid this alignment. Then fully tighten.

  3. Install the clamp bracket (rotate the lever to help with the installation), the hose retaining ring, and the slide bar supports to the slide bar.

  4. Make sure that the wall screws are flush with the inside edge of the mounting brackets. Fit the slide bar supports over the mounting brackets, then adjust the slide bar vertically ensuring an equal length of slide bar protrudes from the top and bottom mounting bracket (or flush with the end of the slide bar for new installations).

  5. Remove the slide bar assembly carefully, preventing any further movement between the slide bar and the slide bar supports.

  6. Tighten the two slide bar clamping screws no more than half a turn to secure the slide bar supports to the slide bar.
    Caution! Overtightening these screws will cause damage.

  7. Install the slide bar assembly onto the mounting brackets. Tighten the 2 x M4 screws with the supplied 3 mm hexagonal key.
    Caution! Do not force assembly onto the mounting brackets, re-align a slide bar support if required.

Soap Dish Installation
  1. Loosely secure the tapered block into the soap dish with the soap dish screw.
  2. Insert the soap dish assembly into the slide bar and tighten the screw.
    Caution! Do not overtighten.
Hose and Handset Installation
  1.  Fit a hose seal into the conical nut and screw onto the outlet of the shower.
    Caution! Do not overtighten.

  2. Feed the hose through the hose retaining loop of the soap dish.

  3. Fit a hose seal into the conical nut and screw onto the handset.
    Caution! Do not overtighten.

  4. Place the showerhead assembly into the clamp bracket assembly.

Note! Do not overtighten the screws

KOHLER Mira Sport Shower Fittings L16J - Do not overtighten the
screws

USER MAINTENANCE

De-scaling the Showerhead
Important! Keeping the showerhead clean and free from limescale will ensure that your shower and showerhead continue to perform to their maximum. A blocked showerhead can restrict the flow rate and may cause damage to your shower.
Use your thumb or a soft cloth to wipe any limescale from the soft nozzles

KOHLER Mira Sport Shower Fittings L16J - De-scaling the
Showerhead

Inspecting the hose

Important! The shower hose should be inspected periodically for damage or internal collapse, internal collapse can restrict the flow rate from the showerhead and may cause damage to the shower. Remove the shower hose from the shower, inspect and replace the hose if necessary.

KOHLER Mira Sport Shower Fittings L16J - tInspecting the
hose

SPRAY MODES

KOHLER Mira Sport Shower Fittings L16J -SPRAY MODES

When adjusting shower spray modes do not force lever as product damage will occur.

CUSTOMER SERVICE

Guarantee
Your product has the benefi t of our manufacturer’s 1-year guarantee which starts from the date of purchase. Within the guarantee period, we will resolve defects in materials or workmanship, free of charge, by replacing parts or products as we may choose.
This guarantee is in addition to your statutory rights and is subject to the following conditions :

  • The product must be installed and maintained in accordance with the instructions given in this user guide.

  • Replacement under this guarantee does not extend the original expiry date. The guarantee on any replacement parts or product ends at the original expiry date.
    The guarantee does not cover:

  • Nonproduct faults (such as damage or performance issues arising from incorrect installation, improper use, inappropriate cleaning, lack of maintenance, build-up of limescale, frost damage, corrosion, chemical attack, system debris, or blocked fi liters) or where no fault has been found with the product.

  • Accidental or wilful damage.

  • Compensation for loss of use of the product or consequential loss of any kind.

  • Damage or defects are caused if the product is repaired or modifi ed by persons not authorized by us or our appointed representative.

What to do if something goes wrong
If your product does not function correctly when you fi first use it, check that it is installed and commissioned in accordance with the instructions in this manual. If this does not resolve the issue, contact us for help and advice.
Helpdesk Service
Contact our Customer Service Team for product advice, to purchase spare parts or accessories, or to request a service visit. You can contact us via phone or e-mail – contact details are below. Please provide your model name, power rating (if applicable), and date of purchase.
Mira Showers Website (www.mirashowers.co.uk)
Visit our website to register your guarantee, download user guides, diagnose faults, purchase our full range of accessories and popular spares, or request a service visit.

Spares and Accessories
We hold the largest stocks of genuine Mira spares and accessories. Contact us for a price or visit our website to purchase items from our accessory range and popular spares (Only available in the United Kingdom.)

To Contact Us: UK

0844 571 5000
Please note: Calls cost 7p per minute plus your phone company’s access charge.
01242 282595
**Email – Visitwww.mirashowers.co.uk/contactus
By Post:
Mira Customer Services Dept, Cromwell Road, Cheltenham, Gloucestershire, GL52 5EP
To Contact Us: Eire Only
01 531 9337**
Email CustomerServiceEire@mirashowers.com

KOHLER Mira Sport Shower Fittings L16J -1Mira is a registered trademark of Kohler Mira Limited.
The company reserves the right to alter product specifi cations without notice.

1269096-W2-A
© Kohler Mira Limited, September 2015

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals