Mira Galena
9.8 kW
User Manual Installation and User Guide
Mira Galena 9.8 kW Electric Shower
These instructions must be left with the user
For SPARES, ADVICE or REPAIRS
Please call us on 0844 571 5000 (UK Only)
Showering perfection
INTRODUCTION
Thank you for purchasing a quality Mira
product. To enjoy the full potential of your new product, please take time to
read this guide thoroughly. Having done so, keep it handy for future
reference.
The Mira Galena is a thermostatic electric
shower with separate
controls for power selection and temperature/flow adjustment. A unique
thermostatic valve
stabilizes temperature changes caused by water pressure fluctuations. These
can result from taps being turned on or off, or a toilet being flushed. An
individual light indicates “START/STOP”.
The Mira Galena comes complete with a set of
Mira Energise Shower Fittings.
Mira Galena 9.8 kW
A 9.8 kW 240 V AC (9.0 kW 230 V AC) heater with Mira Energise adjustable spray
handset with four different spray actions (start, soothe, force and eco*).
Supplied complete with flexible hose, clamp bracket assembly, slide bar,
supports, hose retaining ring and soap dish. Available in a black slate,
metallic silver, black flock and light stone finish.
- The ‘eco’ setting will have no effect, and will give the same spray action as the ‘start’ setting.
Guarantee
For domestic installations, Mira Showers guarantee the Mira Galena 9.8 kW against any defect in materials or workmanship for a period of two years from the date of purchase (shower fittings for one year).
For non-domestic installations, Mira Showers guarantee the Mira Galena 9.8 kW against any defect in materials or workmanship for a period of one year from the date of purchase.
For terms and conditions refer to section “Customer Services”.
Patents and Design Registration
Design Registration: | 000578463-001-002 |
---|---|
Patents: | GB: 2 341 667, 2 404 000, 2 428 286, 2 427 460 Ireland: 82835, |
85128, 85163, 85912
If you experience any difficulty with the installation or operation of your new Electric Shower, please refer to ‘Fault Diagnosis’, before contacting Kohler Mira Ltd. Our telephone and fax numbers can be found in the back of this guide.
IMPORTANT SAFETY INFORMATION
WARNING – This shower can
deliver scalding temperatures if not operated, installed or maintained in
accordance with the instructions, warnings and cautions contained in this
guide and on or inside the appliance.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:
-
Installation of this shower must be carried out in accordance with these instructions by qualified, competent personnel.
-
Isolate the electrical and water supplies before commencing installation. The electricity must be isolated at the consumer unit and the appropriate circuit fuse removed, if applicable. Mains connections are exposed when the cover is removed.
-
DO NOT install the shower in areas with high humidity and temperature (i.e. steam rooms and saunas).
-
DO NOT install the shower where it may be exposed to freezing conditions.
Ensure that any pipework that could become frozen is properly insulated. -
DO NOT switch the shower on if there is a possibility that the water in the shower is frozen.
-
DO NOT switch the shower on if water starts leaking from the shower case.
Isolate the electrical supply to the shower immediately. -
DO NOT connect the outlet of the shower to any tap, control valve, trigger handset or showerhead other than those specified for use with this shower – scalding water temperatures and product damage may occur. Only Kohler Mira recommended accessories should be used.
-
The water supplies to this product must be isolated if the product is not to be used for a long period of time. If the product or pipework is at risk of freezing during this period they should also be drained of water.
-
DO NOT perform any unspecified modifications to the shower or it’s accessories.
When servicing only use Genuine Kohler Mira replacement parts. -
If the shower is dismantled during installation or servicing then upon completion the product must be inspected to ensure all electrical connections are tight and that there are no leaks.
-
Read all installation instructions before installing this shower.
-
Upon completion of the installation, make sure that the user is familiar with the operation of the shower, and leave this guide with the owner.
PACK CONTENTS CHECKLIST
Tick the appropriate boxes to familiarise yourself with the part names and to
confirm that the parts are included.
Mira Galena
Documentation
1 x Installation and User Guide
1 x Guarantee and Registration Document
1 x Installation Template
WIRING DIAGRAM
SPECIFICATIONS
European Conformity Information
The Mira Galena shower complies with the following European directives:
2006/95/EC Low Voltage Directive, 2004/108/EC EMC Directive.
The Mira Galena shower is a high power appliance and is subject to conditional
connection. If the main electrical supply fuse is rated less than 80 Amps, the
local electricity supply company must be contacted to confirm if the
electrical supply is adequate.
The Mira Galena shower complies with the requirements of the UK’s water
regulations.
Plumbing | Variant |
---|
Galena 9.8
Minimum Dynamic Pressure| 70 kPa (0.7 bar)
Maximum Dynamic Pressure| 500 kPa (5 bar)
Maximum Static Pressure| 1000 kPa (10 bar)
Minimum Static Pressure| 20 kPa (0.2 bar)
Maximum Inlet Temperature| 30°C
Minimum Inlet Temperature| 2°C
Inlet Connection| 1/2” BSP Male / 15 mm Compression Fitting
Maximum Water Hardness| 200 ppm CaCO3
Outlet Connection| 1/2” BSP Male
Electrical| Variant
---|---
Galena 9.8
Nominal Power at 230 V ac| 9.0 kW
Nominal Power at 240 V ac| 9.8 kW
Recommended MCB Rating| 45 A
Maximum Supply Cable Size| 16 mm²
Recommended RCD Rating| 30 mA tripping current
Recommended Isolator Switch| 45 A double-pole with 3 mm contact separation
Appliance Sealing Rating| IP X4 – Suitable for installation in Zone 1
Maximum Ambient Temperature| 30°C
Minimum Ambient Temperature| 2°C
Dimensions|
---|---
Height| 367 mm
Width| 233 mm
Depth| 100 mm
INSTALLATION REQUIREMENTS
Please read the Important Safety Information and specifications sections at
the front of this guide, and the requirements detailed in this section before
installing the shower.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: Plumbing
-
The plumbing installation must comply with all national or local water regulations and all relevant building regulations, or any particular regulation or practice specified by the local water supply company.
-
Do not install the product in a position in which service access is limited.
-
Decide on a suitable position for the shower (minimum distance of 200 mm from the ceiling to allow for cover fit and removal).
-
The position of the shower and shower fittings must provide a minimum gap of 25 mm between the showerhead and the spill over level of any bath, shower tray or basin and a minimum gap of 30 mm between the showerhead and the spill over level of any toilet, bidet or other appliance with a Fluid Category 5 backflow risk (see diagram on page 8).
-
The shower is suitable for installation within the shower area and is fitted with a pressure relief valve. It must be positioned over a water catchment area with the controls at a convenient height for the user.
-
The shower must be fitted to a waterproof flat and even wall surface.
-
DO NOT fit the shower to the wall and tile up to the case.
-
DO NOT seal the gap between the shower and the wall surface.
-
The showerhead should be positioned so that it discharges down the centre line of the bath or across the opening of a shower cubicle.
-
The showerhead must be directed away from the shower unit, during normal use the showerhead must not spray directly on to the shower unit.
-
DO NOT apply excessive force to plumbing connections; always provide mechanical support when making plumbing connections. Any soldered joints should be made before connecting the shower.
-
This shower is not designed to be plumbed directly from the rear. For rear-entry supply, add an elbow to the supply pipe and connect as a rising or a falling supply.
-
If pipework and/or electrical cables enter the shower from the rear through a hole in the wall provision must be made to prevent water ingress back into the wall structure.
-
Only use the inlet connector supplied with the shower. DO NOT use any other type of fitting.
-
A full bore/non restrictive servicing valve must be fitted in a readily accessible position adjacent to the shower to facilitate maintenance of the shower.
DO NOT use a valve with a loose washer plate (jumper) as this can lead to a build up of static pressure. -
A water treatment device should be installed where the water hardness may exceed 200 ppm. Malfunctions caused by excessive limescale formation are not covered by this shower’s guarantee (see back page for details).
-
The installation must not cause the hose to be sharply kinked during normal use.
-
DO NOT perform the electrical installation until the plumbing has been completed and checked for leaks.
Hose Retaining Ring fitted and shower
fittings fixed at a
suitable height preventing dirty water backflow.
Note! There will be occasions when the hose retaining ring will not provide a
suitable solution for Fluid Category 3 installations, in these instances an
outlet double checkvalve must be fitted, this will increase the required
supply pressure typically by 10kPa (0.1 bar). Double checkvalves fitted in the
inlet supply to the appliance cause a pressure build up, which could exceed
the maximum static inlet pressure for the appliance and must not be fitted.
For Fluid Category 5 double checkvalves are not suitable.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:
Electrical
- The electrical installation must comply with BS 7671 (commonly referred to as the IEE Wiring Regulations) and all relevant building regulations, or any particular regulation or practice specified by the local electricity supply company.
- Ensure that all circuit protection devices, switches and cabling is adequate for the rated current of the shower and that the rating of the electricity supply company fuse and the consumer unit are adequate for the additional demand.
- The shower must be earthed. Ensure any supplementary bonding complies with the relevant regulations.
- This shower is intended to be permanently connected to the fixed electrical wiring of the mains system. A separate supply must be provided from the consumer unit to the shower.
- DO NOT supply any other electrical equipment including extractor fans or pumps via this product.
- This shower must be provided with means for local disconnection that is incorporated into the fixed wiring in accordance with the relevant local wiring regulations. This must be a double pole switch, which has at least 3 mm contact separation in each pole. The switch can be a ceiling mounted pull-cord type within the shower room or a wall mounted switch fitted in the applicable zone area.
- A 30mA Residual Current Device (RCD) is recommended to be fitted in the circuit to the shower.
- DO NOT apply excessive force to the terminal block.
- All electrical connections should be checked for tightness to prevent overheating before switching on the electrical supply.
- DO NOT switch on the electrical supply until the plumbing has been completed and checked for leaks.
INSTALLATION
Installation ofMira Galena
Warning! Turn off the electrical and water supplies before proceeding
with the installation of the Mira Galena. The electricity must be turned off at the
mains and the appropriate circuit fuse removed, if applicable.
Note! An installation template is supplied to help you install the Mira
Galena.
Wall fixings are not supplied. For solid wall structures a red rawl plug and a
no. 8 x 1½” countersunk brass or stainless steel screw should be used. For
other wall structures such as panels alternative fixings may be required. A
minimum of 3 fixing screws should be used.
Remove the three cover retaining screws and the cover.
Caution! Handle the cover assembly with care.
Determine the direction and route of the incoming water supply: falling
(entering the shower from the
top), or rising (entering the
shower from the bottom).
Note! – DO NOT use an incoming supply entering the
shower directly from the back.
Add an elbow to the supply pipe and connect it as a rising or falling supply.
Swivel the inlet connector assembly to suit. Remove the inlet blanking cap.
Avoid trapping the green earth bonding wire. Before fitting the cover, make sure that the appropriate
cutouts have been removed to suit the supply entering the product.
Thoroughly flush the mains-fed cold water supply pipe. The supply must be
clean and free from debris BEFORE connecting the appliance.
To flush the pipework, turn on the water supply and drain a minimum of 10
litres (2 gallons) of water into a bucket or catchment area. Turn off the
water supply.
An installation template is supplied to help you install the Mira
Galena.
Put the installation template on the wall and mark through the positions of
the fixing holes. Ensure the position of these holes do not come in line with
any buried cables or pipework. Make sure that sufficient electrical supply
cable is available for connection to the terminal block.
Drill and plug the top two fixing holes. Secure the appliance to the wall with
appropriate screws. Drill the bottom fixing hole with the product in place.
Alternative fixings (not supplied) may be necessary for some wall structures.
Avoid drilling into any supply cable/pipe.
Install the mains-fed cold water supply pipe. Do not overtighten.
(See Plumbing Installation Requirements). Firmly
connect the conductors. Do not exert strain on the terminal block.Refit the cover, making sure it is correctly located. Do not
overtighten screws.
Caution! Handle the cover assembly with care.
Do not use alternative screws to secure the cover. This can cause internal
damage to the appliance.
Do not seal around the back of appliance.
When fitting the cover, position the controls to correspond with the internal
drive features as shown.
COMMISSIONING
Before carrying out the commissioning procedure install the Shower
Fittings, refer to
the Shower Fittings Installation and User Guide.
If you are unsure how an electric shower works, please read through the section “User
Instructions” before continuing.Note! A slight hissing sound may be heard from the
appliance during operation.
High mains water pressure and high
shower temperatures will affect
the tone. This is quite normal in use.
USER INSTRUCTIONS
How Your Electric Shower Works Heated water is produced by adjusting the flow of cold water passed through a heater tank.![KOHLER Mira Galena 9.8 kW Electric Shower
- USER INSTRUCTIONS 1](https://manuals.plus/wp-content/uploads/2024/03/KOHLER-
Mira-Galena-9.8-kW-Electric-Shower-USER-
INSTRUCTIONS-1.jpg)Thermostatic (Temperature-Stable)
The shower’s top priority is to keep the desired water temperature constant. Electric showers with thermostatic control are able to keep a stable temperature across the range from hot to cold, whilst also dealing with fluctuations in electrical and water supplies. As a result, there is a temperature limit the shower cannot go beyond. For safety, this temperature is factory set and cannot be adjusted to make the shower hotter or colder.
USER SAFETY INFORMATION
WARNING – THIS SHOWER CAN
DELIVER SCALDING TEMPERATURES IF NOT OPERATED, INSTALLED OR MAINTAINED IN
ACCORDANCE WITH THE INSTRUCTIONS, WARNINGS AND CAUTIONS CONTAINED IN THIS
GUIDE AND ON OR INSIDE THE APPLIANCE.
To reduce the risk of fire, electric shock or injury:
- Make sure that you fully understand how to operate this shower before use, read all operating instructions and retain this guide for future reference.
- This shower is not intended for use bypersons (including children) with reducedphysical, sensory or mental capabilities, or lack of experience and knowledge,unless they have been given supervision or instruction concerning the use of the shower by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the shower.
- DO NOT switch the shower on if there is a possibility that the water in the shower is frozen.
- DO NOT switch the shower on if water leaks from the shower unit. Isolatethe electrical supply to the shower immediately.
- DO NOT switch the shower on if the case appears to be damaged or incorrectlyfitted. Isolate the electrical supply to the shower immediately.
- DO NOT connect the outlet of the shower to any tap, control valve, trigger handset or showerhead other than those specifiedfor use with this shower – scalding water temperatures and product damage may occur. Only Kohler Mira recommended accessories should be used.
- The showerhead must be de-scaled regularly, refer to the user maintenance section towards the rear of this guide for details.
- The shower hose must be checkedregularly and replaced if damaged, refer to the user maintenance section towards the rear of this guide for details.
- DO NOT store bathroom items on top of the shower case. ie. Shampoo or shower gel containers.
- Always check the water temperature before entering the shower. Sunburn or skin conditions can increase your sensitivity to hot water. Make sure that you set the shower to a cooler temperature.
- DO NOT operate the temperature control rapidly, allow 10 – 15 seconds for the temperature to stabilise before use.
- DO NOT block or restrict flow through the handset or hose whilst showering. eg. By placing in direct contact with your body.
- Be aware that any adjustment to temperature control or power control whilst showering will affect the showering temperature and may result in a burst of hot water.
- Care is required if the shower is turned off and then back on after a short time as this will result in a burst of hot water from the showerhead. Ensure temperature has stabilised before re-using shower.
- Switch off the appliance at electrical isolating switch when not in use. This is for safety and is recommended with all electrical appliances.
- If any of the following conditions occur, isolate the electricity and water supplies and contact your installer:
If the case is damaged or the cover is not correctly fitted and water has entered the shower case.
If the shower begins to make an odd noise, smell or smoke.
If the shower shows signs of a distinct change in performance indicating a need for maintenance.
Using yourShower
Read the section “User Safety Information” first. Note! At the end of
every shower make sure that
the shower head points into the
catchment area. A small amount of water may be retained in the shower
handset after the
shower has been turned off.
This may drain over a few minutes.
Switch off the appliance at electrical isolating switch when not in use. This
is for safety and is recommended with all electrical appliances.
The Effect of Seasonal Changes
For a cold shower
select I.
For a summer warm shower select
II.
For a winter warm shower select
III.
During extremes of mains water supply temperature, adjust heater setting to
obtain a better showering temperature.
The Effect of Other Water Devices Water inlet pressure fluctuations due to other draw offs (e.g. flushing toilet). Shower temperature will be controlled to within ± 2°C of the set temperature provided that the supply conditions remain within the required operating parameters (refer to section: ‘Specifications’).
FAULT DIAGNOSIS
The trouble shooting information tabled below gives details on probable causes
and remedies should difficulties be encountered whilst the
shower is in operation.
Warning! There are no user serviceable components beneath the cover of the
appliance. Only a competent tradesperson should remove the front cover!
Symptom| Start/ Stop Light| Heater Setting I / II /
III| Probable Cause| Possible Remedy
---|---|---|---|---
Appliance Fails to operate| OFF| ANY| Electrical supply isolated at double
pole switch.| Switch on electrical supply via the pullcord or wall mounted
switch.
Fuse blown or MCB/RCD tripped, indicating possible electrical fault.| Renew
the fuse or reset the MCB/RCD. If fault persists, contact your installer.
Shower cycles from hot to cold|
ON| II / III| Showerhead blocked| Remove and clean.
W ater pressure below minimum required for appliance operation.| Make sure
incoming mains wa ter stop cock an d/or appliance isolating valve is fully
turned on.
Temperature dial or Heater setting too high.| Turn the heater selector knob to
setting II or turn the temperature control until a cooler temperature is
achieved.
Thermostatic mechanism
is faulty or damaged.| Replace.
Unable to select a cool enough
shower.| ON| III| Due to the
rise in mains water supply temperature, the Heater setting may be too high.|
Turn the heater selector knob to II and adjust the temperature control until a
suitable temperature is achieved.
Unable to select a hot enough
shower (cold only)| ON| I / II|
Power control not on high| Turn the power control to high
ON| ANY| Temperature control on cool setting| Turn the temperature control
until a hotter temperature is achieved
Water pressure below minimum requirement for
shower operation| Make sure
incoming mains water stopcock and / or
shower isolating valve is fully
open
Contact water company
Showerhead blocked| Remove and descale
showerhead
Hose kinked or blocked| Check hose and replace if necessary, see section –
‘USER MAINTENANCE’.
Restriction in Showerhead mode| Select different
Showerhead mode
Symptom| Start/ Stop Light| Heater Setting I / II /
III| Probable Cause| Possible Remedy
---|---|---|---|---
Handset dripping| OFF| ANY| Insufficient water supply pressure for shut off.|
The minimum static pressure to ensure shut off and prevent dripping is 0.2
bar.
Note! If other appliances are operating, static pressure may drop below
0.2 bar. Contact local water company. Renew the Flow Valve.
Inlet valve faulty| Replace
Low or no flow.| ON| ANY| Water supply pipework or inlet filter restricted by
a blockage or partial blockage.| Flush supply pipe. Clean inlet filter.
Insufficient water supply pressure/flow for operation.| Contact local water
company. Supply pressure must be a minimum of 0.7 bar. Note: If other
appliances are operating, pressure may drop below 0.7 bar.
Other outlets (e.g. toilet, garden hose, washing machine, etc.) drawing water
while the shower is being
used.| Turn off other appliances whilst
shower is in use.
Showerhead blocked.| Remove and clean.
OFF| ANY| Service tunnel or cover not fitted correctly causing Start/ Stop
button not to operate.| Check case inserts are cut and fitted correctly. Check
services (electrical or plumbing) are not interfering with location of service
tunnel or cover.
ON| ANY| Inlet Valve faulty.| Replace.
Heater Tank excessively scaled.| Replace. In hard water areas consider the use
of a water softener.
Operation of temperature control has little or no effect on water
temperature.| ON| II / III| Showerhead or inlet filter blocked.| Remove and clean.
Inlet valve faulty.| Replace.
Heater tank failure.| Replace.
Microswitch failure.| Replace.
Symptom| Start/ Stop Light| Heater Setting I / II /
III| Probable Cause| Possible Remedy
---|---|---|---|---
No change in temperature between I/II/III settings.| ON| ANY| Insufficient
mains water pressure.| Contact local water company.
Possible failure of flow valve, microswitch or heater tank.| Check the
continuity of the microswitch or heater tank and replace parts as necessary.
Water will not turn off.| ON| ANY| Inlet valve, solenoid, or start/ stop
switch faulty.| Replace as necessary.
Supply pressure below 0.2 bar.| Contact local water company. Check mains water
static pressure.
Appliance fails to produce hot water when set on II/III heater settings.| ON|
II / III| Insufficient water supply| Contact local water company.
P os s ible f ailur e of t he microswitch or thermal switch.| Check the
continuity of the microswitch or heater tank and replace parts as necessary.
Heater Tank failure.| Replace.
USER MAINTENANCE
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:
- There are no user serviceable parts inside the shower. Only qualified, competent personnel should remove the front cover, mains connections are exposed when the cover is removed.
- Switch the shower off at the isolator switch before performing any user maintenance or before cleaning the shower.
- DO NOT allow young children to perform user maintenance including cleaning of the shower.
- DO NOT use the showerhead to clean the shower.
- If the shower is not to be used for a long period, the electrical supply and water supply to the shower should be isolated. If the shower or pipework is at risk of freezing during this period a qualified, competent person should drain them of water.
Cleaning
Many household cleaners contain abrasives and chemical substances, and should
not be used for cleaning plated or plastic parts or fittings. These finishes
should be cleaned with a mild washing up detergent or soap solution, and then
wiped dry using a soft cloth.
De-scaling theShowerhead
Important! Keeping the showerhead clean and free from limescale will ensure that your
shower and showerhead
continue to perform to their maximum.
A blocked showerhead can
restrict the flow rate and may cause damage to your shower Inspecting the
hose.
Important! The shower
hose should be inspected periodically for damage or internal collapse,
internal collapse can restrict the flow rate from the
showerhead and may cause
damage to the shower.
Remove the shower hose
from the shower, inspect
and replace the hose if necessary.
SERVICING
WARNING
There are no user serviceable parts inside the
shower.
Servicing of the shower must
only be carried out by qualified, competent personnel following the
instructions provided in this guide and those provided with any spare part.
Before replacing any parts, ensure that the underlying cause of the
malfunction has been resolved.
Inlet Filter – Cleaning/Renewing
Read the section “Important Safety Information” first
Make sure that the electrical supply is turned off at the mains and that the
water supply is fully turned off.
Remove the three screws and the cover.
Caution! Handle the cover assembly with care. Hold a wrench across the
flats of the metal connector. Unscrew the filter using another wrench as
shown. Clean or renew the Filter as necessary. Refit in reverse order making
sure the Filter is screwed fully home.
Do not overtighten! Make sure plumbing connections are sealed before restoring
electricity supply.
Refit the cover making sure it is correctly located. Do not overtighten the
screws.
SPARE PARTS
416.38 | Clamp Bracket (Inlet) |
---|---|
416.41 | Thermal Switch |
416.48 | Latching Switch |
416.51 | Solenoid Coil |
872.01 | Microswitch N/O – 2 pin |
872.28 | Microswitch C/O – 3 pin |
1563.519 | Terminal Block Assembly |
1563.533 | Thermostatic |
Valve/Heater Tank 9.8 kW 240 V AC
1563.534| Outlet Connector Assembly
1563.537| Temperature Control Belt Thermostatic
1563.538| Temperature Cam & Pulley
1563.539| Switching Assembly
1563.540| Inlet Valve Assembly
1563.551| Component Pack – chrome – components identified ‘B’
1634.010| Cover Assembly – Black Slate
1634.015| Start/Stop LED Assembly
1634.026| Screw Pack – components identified ‘A’
1634.104| Cover Assembly – Metallic Silver
1634.105| Cover Assembly – Black Flock
1634.106| Cover Assembly – Light Stone
1829.062| Inlet Filter (with ‘O’ seal fitted)
1829.063| Inlet Connector Assembly
ACCESSORIES
Genuine Mira accessories can be purchased
direct from Customers Services (our contact details can be found on the back
cover of this guide) or from approved stockists or merchants. Double Outlet
Check Valve (DCV-H)
Chrome – 1.0.110.55.1
DCV-H: An outlet double check valve, designed to prevent the backflow or
backsiphonage of potentially contaminated water, through shower
controls which are
fitted with a flexible hose as part of the outlet
shower fitting.
Showerhead Holder White
– 2.1605.149 Chrome – 2.1605.150
If you’re looking for additional flexibility in your
shower, the Mira Logic
Showerhead Holder is the
perfect solution. Makes showering easier for children, provides a useful
additional holder for your Showerhead which fixes to the wall at the desired
height.Shower Seat
White – 2.1536.128
White/Chrome – 2.1536.129
For use in or out of the showering area. Note! Must be installed onto a solid
wall.
Shower seat folds up when not
in use
Mira Galena Spare Parts Diagram
CUSTOMER SERVICE
Guarantee
Yo ur product has the benefit of our manufacturer’s guarantee which starts
from the date of purchase.
To activate this guarantee, please return your completed registration card,
visit our website or free phone 0800 0731248 within 30 days of purchase (UK
only).
Within the guarantee period we will resolve defects in materials or
workmanship, free of charge, by repairing or replacing parts or product as we
may choose.
This guarantee is in addition to your statutory rights and is subject to the
following conditions:
-
The guarantee applies solely to the original installation under normal use and to the original purchaser only.
The product must be installed and maintained in accordance with the instructions given in this user guide. -
Servicing must only be undertaken by us or our appointed representative. Note! if a service visit is required the product must be fully installed and connected to services.
-
Repair under this guarantee does not extend the original expiry date. The guarantee on any replacement parts or product ends at the original expiry date.
-
For shower fittings or consumable items we reserve the right to supply replacement parts only.
The guarantee does not cover: -
Call out charges for non product faults (such as damage or performance issues arising from incorrect installation, improper use, inappropriate cleaning, lack of maintenance, build up of limescale, frost damage, corrosion, system debris or blocked filters) or where no fault has been found with the product.
-
Water or electrical supply, waste and isolation issues.
-
Compensation for loss of use of the product or consequential loss of any kind.
-
Damage or defects caused if the product is repaired or modifi ed by persons not authorised by us or our appointed representative.
-
Routine maintenance or replacement parts to comply with the requirements of the TMV 2 or TMV 3 healthcare schemes.
-
Accidental or wilful damage.
-
Products purchased ex-showroom display.
What to do if something goes wrong
If your product does not work correctly refer to this manual for fault
diagnosis and check that it is installed and commissioned in accordance with
our instructions.
If this does not resolve the issue, contact us for help and advice.
Extended Guarantees
A selection of protection plans are available that enable you to cover repair
bills (excludes Eire). Ring 01922 471763 for more details.
Helpdesk Service – Ring our Customer
Services Team for product advice, to purchase spare parts or accessories or to
set up service visit. Yo u can contact us via phone or e-mail, details below.
Please provide your model name, power rating (if applicable) and date of
purchase.
Mira Showers Website
(www.mirashowers.co.uk)
Visit our website to register your guarantee, download user guides, diagnose f
aults, purchase our full range of accessories and popular spares, or request a
service visit.
Spares and Accessories – We hold the largest stocks of genuine Mira
spares and accessories.
Contact us for a price or visit our website to purchase items from our
accessory range and popular spares.
Service/Repairs – No one knows our products better than our nationwide team of
Service Te chnicians. We can carry out service or repair work to your product
both during and after the guarantee period. Ask about our fi xed price service
repairs.
To Contact Us: UK
| 0844 571 5000
---|---
| Fax: 01242 282595
| E-mail: Visit
www.mirashowers.co.uk/contactus
| Mira Customer Services Dept, Cromwell Road, Cheltenham, Gloucestershire,
GL525EP
To Contact Us: Eire Only
| 01 531 9337
---|---
| E-mail:
CustomerServiceEire@mirashowers.com
Mira is a registered trade mark of Kohler
Mira Limited.
The company reserves the right to alter product specifi cations without notice.
Check out our full range
ofShowers
Electric Showers
Digital Showers
Mixer Showers
Power Showers
Smart Showers
Shower Towers
From Top Shower Brands
Mira Showers
Aqualisa Showers
Triton Showers
Gainsborough Showers
Shower Pumps can upgrade
your showering experience even more
Stuart Turner Shower Pumps
Salamander Shower Pumps
Grundfos Shower Pumps
© Kohler Mira Limited, November 2013