KOHLER K-682-K Six-Port Thermostatic Valve Instruction Manual

June 6, 2024
Kohler

KOHLER - logo Faucets

DTV®
Six-Port Thermostatic Valve
K-682-K

Features

  • Digitally controlled thermostatic mixing valve.
  • For use with DTV+ system.
  • Anti-scald protection.
  • Six independently controllable 1/2″ NPT outlets.
  • 3/4″ NPT inlets.
  • Maximum flow rate of 21 GPM (10 GPM maximum flow from one outlet).
  • Includes filter screens.
  • Crossflow prevention.
  • High-temperature limit setting for additional protection.

Installation

  • Suitable for use in either showering and/or bathing applications.
  • Can be mounted within a standard 2×4 wall cavity.
  • Includes 110v AC power supply.
  • K-97172-NA Data Cable sold separately.

Required Products/Accessories
K-99693-P digital interface
K-99694 Interface Mounting Bracket
K-99695 System Controller Module
or
K-99693-P digital interface
K-99694 Interface Mounting Bracket
K-99695-E Eco-system controller module

Recommended Products/Accessories
K-97172 Data cable for K-682-K six-port valve K-23723 Faucet cleaner
ASME A112.18.1/CSA B125.1

KOHLER K-682-K Six-Port Thermostatic Valve

Codes/Standards
ASSE 1016/ASME A112.1016/CSA B125.16
UL 1951
CSA C22.2 No. 14
CSA C22.2 No. 68

KOHLER® Electronic Faucets, Valves, and Controls Five-Year Limited
Warranty
See the website for detailed warranty information.

KOHLER K-682-K Six-Port Thermostatic Valve -0 Six-Port Thermostatic
Valve

Technical Information
All product dimensions are nominal.
Thermostatic valve: 120/240 V, 1.5 A, 50/60 Hz
Electrical component rating:
Notes
Install this product according to the installation instructions.
This valve should be used in shower systems only and is not intended to be connected to bath spouts unless installed in a DTV–Bath system.
Provide access for servicing valve.
Use 3/4″ supply lines for optimum performance.
A hot water system equal to 80 gallons (102 L) is recommended.
Pressure regulators are strongly recommended in applications where large pressure swings are anticipated or pressure differences between the supplies exist.
Water hammer arrestors and shut-offs are required in both the hot and cold supplies.
Drain requirements: The maximum flow rate of the valve system is 21 gal/min (79.5 l/min) at 45
psi (310.3 kPa). Use a minimum 3″ (76 mm) single drain, minimum 2″ (51 mm) multiple drains, or a drain system capable of handling the maximum flow rate.

THE B0LD LOOK OF
KOHLER - logo

1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to www.kohler.com.
9-27-2020 06:12 – US/CA/MX

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>