GOODWE HomeKit Monitoring and Zero Discharge User Manual

June 6, 2024
GOODWE

GOODWE logo HomeKit
USER MANUALGOODWE HomeKit Monitoring and Zero
Discharge

No. 90 Zijin Rd., New District, Suzhou, 215011, China service@goodwe.com | www.goodwe.com

INTRODUCTION

This product has the advantages of high precision, small dimensions, convenient operation, and installation. It is equipped with ingle-Phase Meter and Two-Channel External CT to measure and calculate the Power and Energy at the Inverter Output Point,  rid Point and Household Load Point, and upload the measurement and calculation data to the server in real-time over Wi-Fi or n ethernet cable, to realize the measurement, statistics, analysis and management of electric energy at different loads with the  EMS and APP system of GoodWe. ( See the following link for more detailed instructions of SEMS and APP:www.semsportal.com/)

PACKING LIST
1HomeKit
2
CT(Current Transformer)
1Screw Driver
1
Wi-Fi Antenna
1HomeKit Network Quick Configuration Guide
1
USB Seal
1Short Wiring
4
Cable Connection Terminal
1*User Manual

OVERVIEW

HOMEKIT OVERVIEW

GOODWE HomeKit Monitoring and Zero Discharge-
OVERVIEW

CT OVERVIEW

GOODWE HomeKit Monitoring and Zero Discharge- CT
OVERVIEW

INSTALLATION INSTRUCITON

INSTALLATION ENVIROMENT

Protection Class: IP20(for indoor use)
Operating Temperature: -25℃~+60℃

INSTALLATION (WITH DIN TRACK)

① Pull to release the retaining clip
② Mount the HomeKit on the track and push the retaining clip up(a click sound indicates it is installed well)

WIRING CONNECTION

GOODWE HomeKit Monitoring and Zero Discharge-
WIRING

  • Please note the CT location: CT1 is connected to the GridPoint, while CT2 is connected to the Inverter Output Point, and the arrow direction on the CT is pointed to the Grid from the Inverter side. The connection wires of CT are RED corresponding to ‘+’ and BLACK corresponding to ‘-‘.
  • HomeKit is only suitable for Single-Phase grid applications. Please short connect L1 and L2 in the HomeKit side (see the wiring diagram), otherwise, it may cause a measurement error.
  • If you need to set the Export Power Limit function, please connect the inverter and HomeKit using the RS485 cable.

ELECTRICAL DATA

MODEL HK1000
APPLICATION Household Loads Monitoring
Voltage Current Voltage Range
Nominal Voltage 110V/230V
Frequency 50Hz / 60Hz
Nominal Current CT in:120A / 40mA
Current Range 0.48A-120A
Self-Consumption <5W
Data Detection Active Power / Reactive Power

/ Power Factor / Frequency

Energy Calculation| Active/Reactive Power Energy
Precision| Voltage/ Current| Class 1
Active Power| Class 1
Reactive Power| Class 2
Communication| Wi‒Fi or LAN
Weight| 440g
Altitude| <2000m

INTERFACE

INDICATIONS
Indicator Status Description
Power Steady on Power on
Off Power off
Energy consumption Blinking Selling to the utility grid or communicates well

with HomeKit
Steady on| Purchasing from the utility grid
Off| Exceptional communication between the inverter and HomeKit.
Communications| Double blinking| HomeKit is trying to connect to the router.
Quadruple blinking| HomeKit is trying to connect to the server.
Steady on| HomeKit connects to the server successfully.
Off| Communication parameters for connecting HomeKit to the router or the server have not been set in SEMS Portal.

RESET BUTTON
Press Function
1-3s Restore Communication Module of HomeKit to factory Settings
5-10s Restore Meter of HomeKit to factory Settings
>15s Restore Meter of HomeKit to factory Settings and clear energy data
USB PORT

For after-sales maintenance.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals