GOODWE HomeKit Monitoring and Zero Discharge User Manual
- June 6, 2024
- GOODWE
Table of Contents
HomeKit
USER MANUAL
No. 90 Zijin Rd., New District, Suzhou, 215011, China service@goodwe.com | www.goodwe.com
INTRODUCTION
This product has the advantages of high precision, small dimensions, convenient operation, and installation. It is equipped with ingle-Phase Meter and Two-Channel External CT to measure and calculate the Power and Energy at the Inverter Output Point, rid Point and Household Load Point, and upload the measurement and calculation data to the server in real-time over Wi-Fi or n ethernet cable, to realize the measurement, statistics, analysis and management of electric energy at different loads with the EMS and APP system of GoodWe. ( See the following link for more detailed instructions of SEMS and APP:www.semsportal.com/)
PACKING LIST
1HomeKit
2CT(Current Transformer)
1Screw Driver
1Wi-Fi Antenna
1HomeKit Network Quick Configuration Guide
1USB Seal
1Short Wiring
4Cable Connection Terminal
1*User Manual
OVERVIEW
HOMEKIT OVERVIEW
CT OVERVIEW
INSTALLATION INSTRUCITON
INSTALLATION ENVIROMENT
Protection Class: IP20(for indoor use)
Operating Temperature: -25℃~+60℃
INSTALLATION (WITH DIN TRACK)
① Pull to release the retaining clip
② Mount the HomeKit on the track and push the retaining clip up(a click sound
indicates it is installed well)
WIRING CONNECTION
- Please note the CT location: CT1 is connected to the GridPoint, while CT2 is connected to the Inverter Output Point, and the arrow direction on the CT is pointed to the Grid from the Inverter side. The connection wires of CT are RED corresponding to ‘+’ and BLACK corresponding to ‘-‘.
- HomeKit is only suitable for Single-Phase grid applications. Please short connect L1 and L2 in the HomeKit side (see the wiring diagram), otherwise, it may cause a measurement error.
- If you need to set the Export Power Limit function, please connect the inverter and HomeKit using the RS485 cable.
ELECTRICAL DATA
MODEL | HK1000 |
---|---|
APPLICATION | Household Loads Monitoring |
Voltage Current | Voltage Range |
Nominal Voltage | 110V/230V |
Frequency | 50Hz / 60Hz |
Nominal Current | CT in:120A / 40mA |
Current Range | 0.48A-120A |
Self-Consumption | <5W |
Data Detection | Active Power / Reactive Power |
/ Power Factor / Frequency
Energy Calculation| Active/Reactive Power Energy
Precision| Voltage/ Current| Class 1
Active Power| Class 1
Reactive Power| Class 2
Communication| Wi‒Fi or LAN
Weight| 440g
Altitude| <2000m
INTERFACE
INDICATIONS
Indicator | Status | Description |
---|---|---|
Power | Steady on | Power on |
Off | Power off | |
Energy consumption | Blinking | Selling to the utility grid or communicates well |
with HomeKit
Steady on| Purchasing from the utility grid
Off| Exceptional communication between the inverter and HomeKit.
Communications| Double blinking| HomeKit is trying to connect to the router.
Quadruple blinking| HomeKit is trying to connect to the server.
Steady on| HomeKit connects to the server successfully.
Off| Communication parameters for connecting HomeKit to the router or the
server have not been set in SEMS Portal.
RESET BUTTON
Press | Function |
---|---|
1-3s | Restore Communication Module of HomeKit to factory Settings |
5-10s | Restore Meter of HomeKit to factory Settings |
>15s | Restore Meter of HomeKit to factory Settings and clear energy data |
USB PORT
For after-sales maintenance.
Read User Manual Online (PDF format)