INTRODUCTION
-
ABOUT THIS MANUAL
This user manual is intended for the user and enables safe and appropriate handling of the product. It gives a general overview, as well as important technical data and safety information about the product. Before using the product, the user should read and understand the content of this user manual.
For the sake of better understanding and readability, this user manual might contain exemplary pictures, drawings, and other illustrations. Depending on your product configuration, these pictures might differ from the actual design of your product. -
ELATEC SUPPORT
In case of any technical questions, refer to the ELATIC website (www.elatec.com) or contact ELATIC technical support at: support- rfid@elatec.com
In case of questions regarding your product order or if you wish additional copies of this user manual, contact your Sales representative or ELASTIC customer service at: info-rfid@elatec.com -
REVISION HISTORY
VERSION
| CHANGE DESCRIPTION|
EDITION
---|---|---
1
| First edition (replaces ELATIC TWN4 Palon Square M user manual DocRev2, dated 03/2021)| 09/2021
INTENDED USE
TWN4 Palon Square M LF HF is a versatile OEM PCB for integration into third-
party products and devices. It supports enhanced
interfaces, especially RS-485. The new single PCB module inherits all
advantages and tool support of the ELATEC TWN4 family.
Although being a general-purpose PCB module, it is optimized for time
attendance and access control.
The product is intended to be integrated into a host device.
Any use other than the intended use described in this section, as well as any
failure to observe the safety information listed in this
document, will be considered misuse and will void the warranty. ELATEC is not
responsible for any damage or injuries resulting from any misuse of the
product.
SAFETY INFORMATION
Installation
-
The installation of the product should be done by trained and qualified personnel only.
Do not install the product by yourself. -
Metallic materials on or in direct vicinity to the product might reduce the reading performance of the product. In some circumstances, plastic screws should be preferred to metallic screws when installing the product. Refer to the installation instructions or integration manual of the product for more information.
Handling
-
Depending on your product configuration, the product might be equipped with one or more light-emitting diodes (LED).
Avoid direct eye contact with the blinking or steady light of the light- emitting diodes. -
The product has been designed for use under the following conditions:
• Temperature range: -25 °C – 80 °C (operating conditions)
• Relative humidity: 5% – 95% (non-condensing)
• Integration into a host device.
Any use of the product under different conditions might damage the product or alter its reading performance. -
The use of other RFID readers or reader modules in direct vicinity to the product, or in combination with the product might damage the product or alter its reading performance. In case of doubts, contact ELATEC for more information.
-
The user is liable for the use of spare parts or accessories other than the ones sold or recommended by ELATEC. ELATEC is not responsible for any damage or injuries resulting from the use of spare parts or accessories other than the ones sold or recommended by ELATEC.
-
Like most electronic devices, RFID systems generate electromagnetic waves that can vary in amplitude and frequency. It is generally known and accepted that some RFID devices might potentially interfere with personal medical devices, like pacemakers or hearing aids.
Users with a pacemaker or any other medical device should use TWN4 Palon Square M LF HF carefully and refer to the information given by the manufacturer of their medical devices before using TWN4 Palon Square M LF HF or any host device containing TWN4 Palon Square M LF HF.
Maintenance and cleaning
-
Any repair or maintenance work should be done by trained and qualified personnel only.
Do not try to repair or carry out any maintenance work on the product by yourself.
Do not allow any repair or maintenance work on the product by an unqualified or unauthorized third party. -
The product does not need any special cleaning.
Do not use any detergents or other cleaning agents on the product.
Disposal
- The product must be disposed of in accordance with the EU directive on waste electrical and electronic equipment (WEEE) or other applicable local regulations.
Product modifications
- The product has been designed, manufactured, and certified as defined by ELATEC.
Any product modifications not expressly approved by ELATEC, including – but not limited to – modifications of antennas or other radio-related components, is not allowed and will void the warranty and all approvals granted to the product.
If you are unsure about any part of the safety information above, contact ELATEC support.
Any failure to observe the safety information above will be considered misuse and will void the warranty. ELATEC is not responsible for any damage or injuries resulting from any misuse of the product.
TECHNICAL DATA
Power supply
9.0 V – 30 V via connector X1; 4.3 V – 5.5 V via micro USB
Current consumption
Operating: typ. 180 mA @12 V; Idle: typ. 50 mA @12 V; Peak typ. 250 mA @12
V
Antennas
The reader module is equipped with the following antennas:
HF antenna (13.56 MHz)
Dimensions: 62 mm x 62 mm / 2.44 inch x 2.44 inch
Number of turns: 2
LF antenna (125 kHz)
Diameter: 20 mm / 0.79 inch
Number of turns: 234
For more information, refer to the related product data sheet or other technical documents.
MODE OF OPERATION
OPERATING MODE
In order to start operating TWN4 Palon Square M LF HF, it simply has to be
connected directly to a host device.
POWER UP
In case of an external power supply unit is used, the following
requirements must be satisfied:
- Limited power source according to the safety norms listed in the respective declaration(s) of conformity
- Short-circuit current < 8 A
Once TWN4 Palon Square M LF HF is connected to the host, it detects the type of communications cable (e.g. USB), with which it is connected to the host.
ENUMERATION
This is only applicable for the USB version: Once the device has been
powered up, it is waiting for completion of the enumeration by the USB host.
As long as the device is not enumerated, it is entering a minimum power
consumption mode, where both LEDs are turned off.
INITIALIZATION
After powering up and enumeration (in USB mode), the device is turning on
the built-in transponder-reader logic. The green LED is turned on permanently.
Some RFID reader modules need some kind of initialization, which is performed
in this step. After successful initialization, the device sounds like a short
sequence, which consists of a lower tone followed by a higher tone.
NORMAL OPERATION
As soon as the reader module has completed the initialization, it is entering
normal operation. During normal operation, the reader
the module is searching for a transponder continuously.
DETECTION OF A TRANSPONDER
If a transponder is detected by the reader module, the following actions are
performed:
- Send the ID to the host. By default, the USB device sends by emulating keystrokes of a keyboard.
- Sound a beep.
- Turn off the green LED.
- Blink the red LED for two seconds.
- Turn on the green LED.
Within the two seconds timeout, where the red LED is blinking, the transponder, which just has been recognized will not be accepted again. This prevents the reader module from sending identical IDs more than one time to the host.
If during the two seconds timeout of the red LED a different transponder is detected, the complete sequence restarts immediately.
SUSPEND MODE
The USB version of the reader module supports the USB suspend mode. If the USB
host is signaling to suspend via the USB bus, the reader module is turning off
most of its power-consuming peripherals. During this operation mode, no
detection of transponders is possible and all LEDs are turned off. Once the
host is resuming to normal operation mode, this is also signaled via the USB
bus. Therefore, the reader module will resume normal operation too.
COMPLIANCE STATEMENTS
EU
TWN4 Palon Square M LF HF is in compliance with the EU directives and
regulations as listed in the respective declaration of conformity.
RF EXPOSURE COMPLIANCE
RF exposure statement (mobile and fixed devices)
This device complies with the RF exposure requirements for mobile and fixed
devices. However, the device shall be used in such a the manner that the
potential for human contact during normal operation is minimized.
APPENDIX
A – TERMS AND ABBREVIATIONS
TERM
|
EXPLANATION
---|---
HF| high frequency
LF| low frequency
NFC| near field communication
PCB| printed circuit board
RFID| radio frequency identification
WEEE| Waste of electrical and electronic equipment. Refers to Directive
2011/65/EU of the European Parliament and of the Council of the European Union
B – RELEVANT DOCUMENTATION
ELATEC documentation
- ELATEC quick start guide
- TWN4 Palon technical handbook
- TWN4 Palon Square M LF HF datasheet
- TWN4 Palon Square M LF HF integration manual
ELATEC GMBH
Zeppelinstr. 1 • 82178 Puchheim • Germany
P +49 89 552 9961 0 • F +49 89 552 9961 129 • E-mail: info-
rfid@elatec.com
elatec.com
Elatec reserves the right to change any information or data in this document without prior notice. Elatec declines all responsibility for the use of this product with any other specification but the one mentioned above. Any additional requirement for a specific customer application has to be validated by the customer himself at his own responsibility. Where application information is given, it is only advisory and does not form part of the specification. Disclaimer: All names used in this document are registered trademarks of their respective owners.
© 2021 ELATEC GmbH – TWN4 Palon Square M LF HF user manual DocRev1 – 09/2021
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>