ELATEC TWN4 Multitech 2 LEGIC LF HF RFID Reader or Writer Module User Manual
- June 4, 2024
- ELATEC
Table of Contents
ELATEC TWN4 Multitech 2 LEGIC LF HF RFID Reader or Writer Module
INTRODUCTION
ABOUT THIS MANUAL
This user manual is intended for the user and enables a safe and appropriate
handling of the product. It gives a general overview, as well as important
technical data and safety information about the product. Before using the
product, the user should read and understand the content of this user manual.
For the sake of better understanding and readability, this user manual might
contain exemplary pictures, drawings and other illustrations. Depending on
your product configuration, these pictures might differ from the actual design
of your product. The original version of this user manual has been written in
English. Wherever the user manual is available in another language, it is
considered as a translation of the original document for information purposes
only. In case of discrepancy, the original version in English will prevail.
SCOPE OF DELIVERY
COMPONENTS AND ACCESSORIES
Depending on your product configuration, the product can be delivered alone or
with different components and accessories, such as cables or wall holders, as
part of a kit. For more information about the delivered components and
accessories, refer to your delivery note, consult the ELATEC website or
contact ELATEC.
SOFTWARE
The product is delivered ex-works with a specific software version (firmware).
Refer to the label attached to the product to find the software version
installed ex-works.
ELATEC SUPPORT
In case of any technical questions, refer to the ELATEC website
(www.elatec.com) or contact ELATEC technical support
at support-rfid@elatec.com In case of questions
regarding your product order, contact your Sales representative or ELATEC
customer service at info-rfid@elatec.com
REVISION HISTORY
VERSION | CHANGE DESCRIPTION | EDITION |
---|---|---|
02 | Chapter “Technical Data” updated | 07/2022 |
01 | First edition | 06/2022 |
INTENDED USE
ELATEC TWN4 family of RFID readers and writers allows users to read and write
to almost any 125 kHz and 13.56 MHz tags and/or labels – it supports all major
transponders from various suppliers like ATMEL, EM, ST, NXP, TI, HID, LEGIC,
etc. and ISO standards like ISO 14443A/B (T=CL), ISO 15693, ISO 18092 /
ECMA-340 (NFC). The TWN4 MultiTech 2 LEGIC LF HF reader/writer has integrated
RFID (LF & HF) and NFC, which is supported by mobile phones with Android
version 4.3 or greater. The app on the reader communicates with the NFC module
with easy commands.
The product is for indoor use and may not be used outdoor. Any use other than
the intended use described in this section, as well as any failure to comply
with the safety information given in this document, is considered improper
use. ELATEC excludes any liability in case of improper use or faulty product
installation.
SAFETY INFORMATION
Unpacking and installation
- The product contains sensitive electronic components that require particular attention when unpacking and handling the product. Unpack the product carefully and do not touch any sensitive components on the product. In case the product is equipped with a cable, do not twist or pull the cable.
- The product is an electronic product whose installation requires specific skills and expertise. The installation of the product should be done by a trained and qualified personnel only. Do not install the product by yourself.
Handling
- Depending on your product configuration, the product might be equipped with one or more light-emitting diodes (LED). Avoid direct eye contact with the blinking or steady light of the light-emitting diodes.
- The product has been designed for a use under specific conditions (refer to the product data sheet). Any use of the product under different conditions might damage the product or alter its reading performance.
- The use of other RFID readers or reader modules in direct vicinity to the product, or in combination with the product might damage the product or alter its reading performance. In case of doubts, contact ELATEC for more information.
- The user is liable for the use of spare parts or accessories other than the ones sold or recommended by ELATEC. ELATEC excludes any liability for damages or injuries resulting from the use of spare parts or accessories other than the ones sold or recommended by ELATEC.
- Like most electronic devices, RFID systems generate electromagnetic waves that can vary in amplitude and frequency. It is generally known and accepted that some RFID devices might potentially interfere with personal medical devices, like pacemakers or hearing aids. Users with a pacemaker or any other medical device should use TWN4 MultiTech 2 LEGIC LF HF carefully and refer to the information given by the manufacturer of their medical devices before using TWN4 MultiTech 2 LEGIC LF HF.
Maintenance and cleaning
- Any repair or maintenance work should be done by a trained and qualified personnel only. Do not try to repair or carry out any maintenance work on the product by yourself. Do not allow any repair or maintenance work on the product by an unqualified or unauthorized third party.
- The product does not need any special cleaning. However, the housing may be carefully cleaned up with a soft, dry cloth and a non-aggressive or non-halogenated cleaning agent on the outer surface only. Make sure that the used cloth and cleaning agent do not damage the product or its components (e.g. label(s)).
Disposal
- The product must be disposed of in accordance with the EU directive on waste electrical and electronic equipment (WEEE) or any applicable local regulations.
Product modifications
- The product has been designed, manufactured and certified as defined by ELATEC. Any product modification without prior written approval from ELATEC is prohibited and considered improper use of the product. Unauthorized product modifications may also result in the loss of product certifications.
If you are unsure about any part of the safety information above, contact ELATEC support. Any failure to comply with the safety information given in this document is considered improper use. ELATEC excludes any liability in case of improper use or faulty product installation.
TECHNICAL DATA
Power supply
4.3 V – 5.5 V via USB; 3.3 V ± 5% via generic interface (X1); RS-232 requires
5 V external power supply
Current consumption
RF field on: 140 mA typically
Antennas
The reader is equipped with the following antennas:
HF antenna (13.56 MHz)
- Dimensions: 42 x 47 mm / 1.65 x 1.85 inch
- Number of turns: 3
LF antenna (125 kHz)
- Diameter: 16 mm / 0.63 inch
- Number of turns: 120
For more information, refer to the related product data sheet or other technical documents.
MODE OF OPERATION
The mode of operation described in the following chapter is based on a
standard ELATEC RFID reader equipped with two LEDs. Depending on your product
(number of LEDs, installed firmware, etc.) and in case the product settings
have been modified with the AppBlaster tool, the information below might
differ from your product configuration when in operation. In particular, the
color and sequence of the LEDs on your product might be different.
OPERATING MODE
In order to start operating TWN4 MultiTech 2 LEGIC LF HF, it simply has to be
connected directly to a host device.
POWER UP
In case of an external power supply unit is used, the following requirements
must be satisfied:
- Limited power source according to the safety standards listed in the respective declaration(s) of conformity
- Short-circuit current < 8 A
Once TWN4 MultiTech 2 LEGIC LF HF is connected to the host device, it detects
the type of communications cable (e.g. USB or RS-232), with which it is
connected to the host. In case of RS-232: Additionally, the RS-232 is sending
a version string via RS-232 to the host device.
ENUMERATION
This is only applicable for the USB version: Once the device has been powered
up, it is waiting for completion of the enumeration by the USB host. As long
as the device is not enumerated, it is entering a minimum power consumption
mode, where both LEDs are turned off.
INITIALIZATION
After powering up and enumeration (in USB mode), the device is turning on the
built-in transponder reader logic. The green LED is turned on permanently.
Some RFID readers need some kind of initialization, which is performed in this
step. After successful initialization, the device sounds a short sequence,
which consists of a lower tone followed by a higher tone.
NORMAL OPERATION
As soon as the reader has completed the initialization, it is entering normal
operation. During normal operation, the reader is searching for a transponder
continuously.
DETECTION OF A TRANSPONDER
If a transponder is detected by the reader, following actions are performed:
- Send the ID to the host. By default, the USB device sends by emulating keystrokes of a keyboard. An RS-232 device sends the ASCII code of an ID.
- Sound a beep.
- Turn off the green LED.
- Blink the red LED for two seconds.
- Turn on the green LED.
Within the two seconds timeout, where the red LED is blinking, the
transponder, which just has been recognized will not be accepted again. This
prevents the reader from sending identical IDs more than one time to the host.
If during the two seconds timeout of the red LED a different transponder is
detected, the complete sequence restarts immediately.
SUSPEND MODE
The USB version of the RFID reader supports the USB suspend mode. If the USB
host is signaling suspend via the USB bus, the reader is turning off most of
its power consuming peripherals. During this operation mode, no detection of
transponders is possible and all LEDs are turned off. Once the host is
resuming to normal operation mode, this is also signaled via the USB bus.
Therefore, the reader will resume to normal operation too.
COMPLIANCE STATEMENTS
EU
TWN4 MultiTech 2 LEGIC LF HF is in compliance with the EU directives and
regulations as listed in the respective EU declaration of conformity.
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Caution
The Federal Communications Commission (FCC) warns the users that changes or
modifications to the unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
FCC §15.105 (b)
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Contains FCC ID: WP5TWN4F22
IC
This device complies with Industry Canada’s license-exempt RSSs. Operation is
subject to the following two conditions:
- This device may not cause interference; and
- This device must accept any interference, including interference that may cause undesired operation of the device.
Contains IC: 7948A-TWN4F22
RF EXPOSURE COMPLIANCE
RF exposure statement (mobile and fixed devices) This device complies with the
RF exposure requirements for mobile and fixed devices. However, the device
shall be used in such a manner that the potential for human contact during
normal operation is minimized.
UNITED KINGDOM
TWN4 MultiTech 2 LEGIC LF HF complies with the requirements of the UK
legislations and other regulations as listed in the respective UK declaration
of conformity. The importer is responsible for applying the following
information to the packaging of the product:
- the importer company’s details, including the company’s name and a contact address in the United Kingdom.
- UKCA marking
APPENDIX
A – TERMS AND ABBREVIATIONS
TERM | EXPLANATION |
---|---|
FCC | Federal Communications Commission |
HF | high frequency |
IC | Industry Canada |
LED | light-emitting diode |
LF | low frequency |
NFC | near field communication |
PCB | printed circuit board |
RFID | radio frequency identification |
UKCA | UK conformity assessed |
WEEE | Waste of electrical and electronic equipment. |
Refers to Directive 2012/19/EU of the European Parliament and of the Council of the European Union
B – RELEVANT DOCUMENTATION
ELATEC documentation
- ELATEC quick start guide
- TWN4 MultiTech 2 LEGIC LF HF datasheet
ELATEC GMBH
Zeppelinstr. 1 • 82178 Puchheim • Germany
P +49 89 552 9961 0 • F +49 89 552 9961 129
E-mail: info-rfid@elatec.com
elatec.com
Elatec reserves the right to change any information or data in this document without prior notice. Elatec declines all responsibility for the use of this product with any other specification but the one mentioned above. Any additional requirement for a specific customer application has to be validated by the customer himself at his own responsibility. Where application information is given, it is only advisory and does not form part of the specification. Disclaimer: All names used in this document are registered trademarks of their respective owners. © 2022 ELATEC GmbH – TWN4 MultiTech 2 LEGIC LF HF user manual DocRev2 – 07/2022
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>