EPEVER LS-EPD Solar Charge Controller LandStar User Guide
- June 3, 2024
- EPEVER
Table of Contents
Solar Charge Controller
General Information
LS EPD series solar charge controller adopts the most advanced digital technique and operates fully automatically. It is ideal for extreme environments with corrosion, dust, water etc and has various unique functions:
- Electronic protection: Over charging, over discharging, overload, short circuit and reverse protection of solar module
- High efficient Series PWM charging, increase the battery lifetime and improve the solar system performance
- Widely used, automatically recognize day/night
- Battery LED indicate battery status
- Industrial design, wide application range
- Digital tube menu, only one key solve all setting simply
- Intelligent timer function with 1~13 hours option
- IP67 protection
Features and Mounting
1 | Charging Status LED indicator |
---|---|
2 | Battery Status LED indicator |
3 | Temperature Sensor |
4 | Solar Module Terminals |
5 | Battery Terminals |
6 | Load Terminals |
7 | Digital tube |
8 | Key |
9 | Aluminum housing |
10 | Mounting hole Φ5 |
Mounting
- Connect components to the charge controller in the sequence as shown above picture and pay much attention to the “+” and “-”. Always power the battery firstly.
- After power the battery, check the battery indicator on the controller, it will be green. If it’s not green, please refer to chapter 4.
- The battery fuse should be installed as close to battery as possible. The suggested distance is within 150mm.
Indicators Description and Operation
- Indicator Status Description
Charging Status LED indicator| Green| On Solid| Normal
---|---|---|---
Green| Fast Flashing| Over voltage
Battery Status LED
indicator| Green| On Solid| Normal
Green| Slowly Flashing| Full
Orange| On Solid| Under voltage
Red| On Solid| Over discharged
Radix Point of Digital
tube
(Load indicator)| Red| On Solid| Load ON
Red| Slowly Flashing| Over Load
Red| Fast Flashing| Short Circuit - Operation
- After Powering on, disconnect the PV or connect the PV(Voltage <5V) , the light of the digital tube point go on; Connect the PV(Voltage>6V) ,the light of the digital tube point go off.
- The key can be used to operate switching on/off the load (Manual control) or clearing the faults
- Keeping pressing the button over 5S, It will go to the parameter in browsing mode which can cycle through the parameter item by clicking the button ,after the light of the digital tube point going on.
- After the digital tube displaying the value what you want to configure, releasing the key and waiting 15S, Digital Tube stop flashing, then the configuration is successful.
Load mode
- Manual Control:Control the load via the button.
Note: In the mode of Light ON/OFF and Light ON/Timer, the Load is turned on after 10Min. delay.
- Test Mode (Default):Test Mode is as same as Light Control Mode but no delay.
The correspondence table of Load Work Mode & LED digital tube value
Value | Working mode | Value | Working mode |
---|---|---|---|
0 | Light ON/OFF | O. | Light ON + 8 hours |
1 | Light ON + 1 hours | 1. | Light ON + 9 hours |
2 | Light ON + 2hours | 2. | Light ON + 10 hours |
3 | Light ON + 3hours | 3. | Light ON + 11 hours |
4 | Light ON + 4 hours | 4. | Light ON + 12 hours |
5 | Light ON + 5 hours | 5. | Light ON + 13 hours |
6 | Light ON + 6 hours | 6. | Manual Control |
7 | Light ON + 7 hours | 7. | Test Mode |
Troubleshooting
Faults | Possible reasons | Troubleshooting |
---|
Charging LED indicator off during daytime when sunshine falls on PV modules
properly| PV array disconnection| Check that PV and battery wire connections
are correct and tight
Battery indicator green
fast flashing| Battery voltage higher than over voltage disconnect voltage|
1. Disconnect the solar array and measure the battery voltage whether is too
high; 2. Change the controller; 3. Change the battery
Battery LED indicators red color and loads not working| Battery over
discharged| The controller cut off the output automatically. LED indicator
will return to green automatically when fully
The radix point of digital tube fast flashing and load not working| Short
circuit| Clear short circuit. It is reactivated after delayed 10 seconds for
the first time, If over 1 time,press the key to clear error and the controller
will resume to work after 3s or restart the controller
The radix point of digital tube slowly
flashing and load not working| Over load| Please reduce the number of electric
equipments.
When load power reaches 1.25-1.5 times, 1.5-2 times and 2 times more than
nominal value, controller will automatically close loads in 60 seconds, 5
seconds and 1 second, respectively.
Please press the key to clear error and the controller will resume to work
after 3s or restart the controller
Technical Specifications
Item | LS1024EPD | LS2024EPD | |
---|---|---|---|
Nominal system voltage | 12/24VDC Auto | 12/24VDC Auto | |
Max. PV input voltage | 50V | 50V | |
Rated current | 10A | 20A | |
Equalize Voltage | 14.8V(12V);29.6V(24V) | ||
Boost Voltage | 14.4V(12V);28.8V(24V) | ||
Float Voltage | 13.7V(12V);27.4V(24V) |
Low Voltage Reconnect
Voltage| | 12.6V(12V);25.2V(24V)
Low Voltage Disconnect
Voltage| | 11.2V(12V);22.4V(24V)
Self-consumption| | 12V: s-4.58mA: 24V: .6.01mA
Temperature compensation
coefficient| | -5mV/t/2V ( 25°C )
Working temperature| | -35°C —+50 C
Enclosure| | IP67
Dimension| | 108.5mmx75mmx25.6mm
Mounting size| | 100.5mm
Mounting hole size| | 5
Power cable| | PV/BAT/LOAD:4.0mm2| PV/BAT/LOAD:6.0mm2
Net weight| | 410g| 435g
Any changes without prior notice!
HUIZHOU EPEVER TECHNOLOGY CO., LTD.
Tel:+86-10-82894112/82894962/+86-752-3889706
Website:www.epever.com