SMC DXT1215 Series High Speed Pilot Operated Solenoid Valve Instruction Manual

June 4, 2024
SMC

**INFORMATION

**

High-Speed Pilot Operated Solenoid Valve
High Speed
ON 2.5 ms OFF 3 ms

Large flow rate Enclosure
330 ∗1 L/min (ANR) IP67
Power saving Select from 3*2 or 5 port.
1.5 W (With power-saving circuit)

CompactSMC DXT1215 Series High Speed Pilot Operated Solenoid
Valve

  1. When the inlet side is 0.6 MPa, and the differential pressure is 0.1 MPa
  2. 3-port type: Made to order (-X1)

Applications

Can be used for the air blow and high-speed operation of actuatorsSMC
DXT1215 Series High Speed Pilot Operated Solenoid Valve -
processes

Caution

The applications described here are for reference purposes only. Therefore, the function is not guaranteed. For actual use, please conduct a thorough evaluation and validation testing in order to determine the feasibility under your actual operating conditions.

DXT1215 Series

Valve Specifi cations

Valve type Rubber seal
Fluid Air
Ambient and fluid temperatures [ C] -10 to 60 (No freezing) 1
The internal pilot operating pressure range [MPa] 2-position single

0.6
Response time [ms] 2| ON: 2.5 OFF: 3
Max. operating frequency [Hz]| 2-position single| 200
Manual override| Non-locking push type
Pilot exhaust type| Internal pilot| Common exhaust
Lubrication| Not required
Mounting orientation: 3| Unrestricted
Impact/Vibration resistance 3 [M/S2]| 150/30
Enclosure| IP67
Electrical entry| M8 connector
Coil-rated voltage [V]| 24 VDC
Allowable voltage fluctuation [V]| -5% to +10% of the rated voltage
Power consumption [W]| DC| With power-saving circuit| 1.5
4 [Inrush 6, Holding 1.5]
Surge voltage suppressor| Diode
Indicator light| LED
Weight [g]| 96

  1. The upper limits of the ambient and fluid temperatures vary depending on the operating frequency. (Refer to the graph below.) If a follow-up operation is performed at a duty ratio of 50% or higher, the upper limit value may change. Please contact SMC for further details.

  2. Based on the JIS B 8419:2010 dynamic performance test (Coil temperature: 20°C, pressure: 0.5 MPa, at the rated voltage)

  3. Impact resistance: No malfunction occurred when it was tested in the axial direction and at a right angle to both the main valve and the armature in both an energized and de-energized state, once for each condition. (Values at the initial period)
    Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. The test was performed in both an energized and de-energized state in the axial direction and at a right angle to both the main valve and the armature. (Values at the initial period)

  4. Only applicable to the power-saving circuit specification.

Flow Rate Characteristics

Model Port size Valve flow rate characteristics

1, 5, 3
(P, EA, EB)| 4,2
(A, B)| |
1 →4/2 (P →A/B)| 4/2 →5/3 (A/B →E)
C [dm3/(s•bar)]| b| C [dm3/(s•bar)]| b
DXT1215| 1/8| 1/8| 1.3| 0.37| 1.| 0.23

∗ Calculation of effective area “S” and sonic conductance “C”: S = 5.0 x C

Operating Frequency

SMC DXT1215 Series High Speed Pilot Operated Solenoid Valve -
frequency

Valve Construction

2-position single

SMC DXT1215 Series High Speed Pilot Operated Solenoid Valve -
single

2-position single
Standard 5-port specification| Made to Order
3-port specification (-X1)
---|---
|

Component Parts

No. Description Material
1 Body Aluminum die-casted
2 Spool assembly Aluminum/FKM
3 Plug (For the -X1) Steel

How to Order Valves

SMC DXT1215 Series High Speed Pilot Operated Solenoid Valve -
fig

  1. Coil type
    T: With a power-saving circuit

  2. Rated voltage
    5: 24 VDC

  3. Electrical entry
    **** M8 connector∗1

    W| WO
    With straight connector cable| Without connector cable
    |

∗1 For the connector cable for M8 connectors refer to the back cover. For W, enter the cable length symbol in the . Please be sure to fi ll in the blank, referring to the back cover.

  1. Light/surge voltage suppressor
    U: With light/surge voltage suppressor (Non-polar)

  2. 4(A)/2(B) port size Thread piping
    01: 1/8

  3. Thread type
    Nil| Rc
    ---|---
    F| G
    N| NPT

  4. Made to Order
    Nil| —
    ---|---
    X1| 3-port specifi cation
    [2(B) port plug]

∗ The 3 -the port specification is a specification with the 2(B) port plugged and closed. The 3(EB) port should be kept open for pilot exhaust.

Dimensions

SMC DXT1215 Series High Speed Pilot Operated Solenoid Valve - fig
1

DXT1215 Series
Specific Product Precautions
Be sure to read this before handling the products. For safety instructions and 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: https://www.smcworld.com

Environment
Warning
Do not use the valves in atmospheres in which corrosive gases, chemicals, sea water, water, or water vapor are present or where there is direct contact with any of these.

Manual Override
Warning
The manual override is used for switching the main valve regardless of the valve’s electric signal. As the connected actuator will start operating due to this manual operation, be sure to confi rm that it is safe to do so beforehand.

  • Non-locking push type
    Push the manual override button all the way down.

Installation

Caution
Even if the inlet pressure is within the operating pressure range, when the piping diameter is restricted due to size reduction of the supply port (P), the fl ow will be insuffi client. In such cases, the valve will not switch completely and the cylinder may malfunction.

Surge Voltage Suppressor

  • With power-saving circuit (PWM circuit built-in type, non-polar type)
    The power consumption has been reduced to approx. 1/4 of the startup power by eliminating the need for electrical current for holding. (Effective after being energized for more than 5 ms when the 24 VDC rated voltage is applied)

SMC DXT1215 Series High Speed Pilot Operated Solenoid Valve -
pin

Operating principle
The circuit shown above reduces power consumption by eliminating the need for electrical current for holding in order to save energy. Refer to the electrical power waveform shown in the graph on the right.

SMC DXT1215 Series High Speed Pilot Operated Solenoid Valve -
Power

Residual voltage of the surge voltage suppressor
If a diode surge voltage suppressor is used, there will be a residual voltage of approx. 1 V. Pay attention to the surge voltage protection on the controller side.

M8 Connector Type

  • Connector cable
    · The connector cable for M8 connectors can be ordered as follows.

How to Order
1. To order a solenoid valve and the connector cable at the same time (The connector cable will be included in the shipment of the solenoid valve.)

SMC DXT1215 Series High Speed Pilot Operated Solenoid Valve - fig
3

Symbol Cable length [mm]
1 300
2 500
3 1000
4 2000
5 3000
6 4000
7 5000

SMC DXT1215 Series High Speed Pilot Operated Solenoid Valve - fig
2

2. To order only the connector cable

SMC DXT1215 Series High Speed Pilot Operated Solenoid Valve - Connector
dimensions

Cable length (L Part no.
300 mm V100-49-1-1
500 mm V100-49-1-2
1000 mm V100-49-1-3
2000 mm V100-49-1-4
3000 mm V100-49-1-5
4000 mm V100-49-1-6
5000 mm V100-49-1-7
Sheath O.D. ø3.4 mm
--- ---
Cover diameter ø1.16 mm
Conductor area 0.16 mm²

SMC DXT1215 Series High Speed Pilot Operated Solenoid Valve -
Conductor

Recommended M8 Connector Angle Type

Cable length| PHOENIX CONTACT|
---|---|---
Product no.| Order no.
1.5 m| SAC-3P-1,5-PUR/M 8FR| 1669738
3 m| SAC-3P-3,0-PUR/M 8FR| 0:00
5 m| SAC-3P-5,0-PUR/M 8FR| 1669631
10 m| SAC-3P-10,0-PUR/M 8FR| 1694169

Caution Phoenix Contact products should be ordered directly from the manufacturer or from its distributors.
Caution

  1. The M 8 connector type is IP 6 7 compliant (according to IEC 6 0 5 2 9 ) and protected against dust and water. However, it cannot be used underwater. Select an SMC connector cable (V100-49-1-) or an FA sensor type connector with M 8 threaded 3 -pin specifications conforming to Nippon Electric Control Equipment Association Standard NECA4202 (IEC 60947-5-2).
  2. Do not use a tool to mount the connector as this may damage it. Only tighten the connector by hand. (0.4 to 0.6 N·m)
  3. The application of excessive force on the cable connector will result in it no longer being able to satisfy the IP67 requirements. Please use caution and refrain from applying any force of 30 N or greater on the connector.

Failure to satisfy the IP67 requirements may result if using connectors other than those shown above or if the connector is insufficiently tightened.

Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.

Akihabara UDX 15F,
4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN
Phone: 03-5207-8249 Fax: 03-5298-5362
https://www.smcworld.com
© 2022 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.
Printing AT 590KS Printed in Japan.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SMC User Manuals

Related Manuals