TruSens Z-1000 Small Air Purifiers User Guide

June 6, 2024
TruSens

**TruSens Z-1000 Small Air Purifiers User Guide

**

READ AND SAVE THESE INSTRUCTIONS

Unplug or disconnect the appliance from the power supply before replacing filters or UV-C emitter, or when appliance is not in use.

WARNING:
To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
Do not operate any purifier with a damaged cord or plug, or if the wall socket is loose. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not run cord under carpeting, throw rugs, runners, or similar coverings. Do not run cord under furniture or appliances.
Arrange cord away from traffic area and where it will not be tripped over.

WARNING:
Skin or eye damage may result from directly viewing the light produced by the UV-C emitter in this apparatus. Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation. UV-C radiation may, even in little doses, cause harm to the eyes and skin. Always disconnect power before relamping or servicing. Replace UV-C emitter with 2415105 (for Z-1000), 2415108 (for Z-2000), or 2415111 (for Z-3000), Manufactured by ACCO Brands.

  • Remove all packaging, including the filter bag, before use.
  • Appliances that are obviously damaged must not be operated.
  • This appliance must only be connected to a wall socket outlet matching the supply plug type and rating stated on the rating plate.
  • Locate air purifier near the outlet wall socket and do not use extension cords.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Children shall not play with, clean, or try to maintain the appliance.
  • Replace the UV-C emitter with the model specified within this manual.
  • Do not attempt to service or repair this product yourself.
  • Only use the purifier and SensorPod™ (for Z-2000/Z-3000 only) with the power cable and adapter (Model: KA0601A0900500TWS / P6-090050 US ) provided.
  • Only clean this machine with a damp cloth, do not use solvents or bleach.
  • Ensure appliance is always placed on firm level surface before operation.
  • Do not block or obstruct the air intake or outlet vents.
  • Do not insert fingers or other items into the air intake or outlet vents.
  • For Z-2000/Z-3000 only, when the air purifier is in standby mode the SensorPod™ is still transmitting a signal/data.

Assembly Instruction

Assembly Instructions
Assembly Instructions

Assembly Instructions
Assembly Instructions
Assembly Instructions

Z-1000/Z-2000

Z-3000
Assembly InstructionsAssembly
Instructions

Guarantee

Operation of this machine is guaranteed for two years from date of purchase, subject to normal use. Within the guarantee period, ACCO Brands will at its own discretion either repair or replace the defective machine free of charge. Defects due to misuse or use for inappropriate purposes are not covered under the guarantee. Proof of date of purchase will be required. Repairs or alterations made by persons not authorised by ACCO Brands will invalidate the guarantee. It is our aim to ensure that our products perform to the specifications stated. This guarantee does not affect the legal rights which consumers have under applicable national legislation governing the sale of goods.

Model Z-1000 Z-2000 Z-3000
Room coverage 23m² 35m² 70m²

Part Name

|

Hazardous Substances

---|---

Lead (Pb)

| Mercury (Hg)| Cadmium (Cd)| Hexavalent Chromium (Cr (VI))| Polybrominated biphenyls (PBB)| Polybrominated diphenyl ethers (PBDE)

Power Supply Cord Plug

| X| O| O| O| O|

O

Power Supply/ Adapter Plug Pins/Blades

|

X

| O| O| O| O|

O

Power Supply/ Adapter Circuit Board

| X| O| O| O| O|

O

UV bulb

|

O

| X| O| O| O|

O

This table was developed according to the provisions of SJ/T 11364.

O: This content of such hazardous substance in all homogeneous material of such component is below the limit required by GB/T 26572

X: the content of such hazardous substance in a certain homogeneous material of such component is beyond the limit required by GB/T 26572

IMPORTANT: Before operation of the purifier, follow the steps and read our TruSens Owners Guide at: www.trusens.com

Set up

  1. Fig. 1)
    Unscrew bottom cover and remove plastic bag from filter

  2. Fig. 2)
    Secure filter on bottom cover and replace inside the purifier

  3. Fig. 3)

    • ① Plug-in your purifier and power on
    • ② Place unit on a flat surface, away from obstructions
    • ③ Plug-in your SensorPodTM (Z-2000/Z-3000)

Control panel (Fig. 4)

  • Power on/of

  • Fan speed

    • Z-1000 Auto / 1 / 2
    • Z-2000 Auto / Whisper / 1 / 2 / Turbo
    • Z-3000 Auto / Whisper / 1 / 2 / 3 / Turbo
  • Dimmer on/off (Z-2000/Z-3000)

  • Timer 2/4/8/12 (Z-2000/Z-3000)

  • UV mode on/of

  • Air Quality Display (Z-2000/Z-3000)

    • 0 – 50 Blue / Good
    • 50 – 100 Yellow / Moderate
    • 100+ Red / Poor
  • Carbon/HEPA/UV replacements

  • SensorPodTM signal indicator (Z-2000/Z-3000)

Filter Replacement

  • Filter Replacement

| Filter type| Suggested Replacement / Cleaning
---|---|---
A.| Washable Prefilter (For Z2000 and Z3000 only)| Hand wash as needed with water
B.| Carbon filter| Every 3-4 months
C.| HEPA Drum Filter| Every 12-15 months
D.| UV Bulb| Every 2-3 years
*Replacements indicator will glow red on control panel to notify you to change.

Fig. 5) Use caution when using a screwdriver to remove the UV housing when

replacing the UV-C emitter.

Company Logo
www.trusens.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals