TruSens Z-6000 Performance Air Purifiers Owner’s Manual

June 5, 2024
TruSens

TruSens Z-6000 Performance Air Purifiers

SAFETY INFORMATION

READ & SAVE THESE INSTRUCTIONS / READ THE LABEL AND ANY OPERATING MANUAL BEFORE USING PRECAUTIONS
Unplug or disconnect the appliance from the power supply before replacing filters, or when appliance is not in use.

WARNING: To reduce the risk of fire or electric shock, do not use this machine with any solid-state speed control device.
Do not operate any purifier with a damaged cord or plug, or if the wall socket is loose.
Do not run cord under carpeting, throw rugs, runners,or similar coverings. Do not run cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
WARNING: Skin or eye damage may result from directly viewing the light produced by the lamps in the apparatus.

WARNING: UV radiation emitted from this device.

  • Unintended use of the device, or damage to the housing, may result in exposure to ultraviolet radiation.
  • Ultraviolet radiation may cause eye and skin irritation.
  • Avoid exposing eyes and skin to ultraviolet radiation.
  • Remove all packaging, including the filter bag, before use.
  • Appliances that are obviously damaged must not be operated.
  • This appliance must only be connected to a wall socket outlet matching the supply plug type and rating stated on the rating plate.
  • Locate air purifier near the outlet wall socket and do not use extension cords.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • KEEP OUT OF THE REACH OF CHILDREN. Children shall not play with the appliance.
  • Do not attempt to sevice or repair this product yourself.
  • Only use the air purifier and SensorPod with the power cable provided.
  • Only clean this machine with a damp cloth, do not use solvents or bleach.
  • Ensure appliance is always placed on firm level surface before operation.
  • Do not block or obstruct the air intake or outlet vents.
  • Do not insert fingers or other items into the air intake or outlet vents.
  • When the air purifier is in standby mode the SensorPod is still transmitting a signal/data.

FIRST AID INSTRUCTIONS – Seek medical attention in event of injury.
The use of this device is a supplement to and not a substitute for standard infection control practices; users must continue to follow all current infection control practices, including those practices related to cleaning and disinfection of environmental surfaces.

Z-6000/Z-7000: FCC ID: GV3-21Z7000
IC: 6128A-21Z7000
Sensor: FCC ID: GV3-21SP0M2 IC: 6128A-21SP0M2
EPA Est. No. 87627-CHN-1

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC RF Radiation Exposure Statement: This equipment should be installed and operated with minimum distance of 20cm between the radiator and all persons.
This device contains licence-exempt transmitter(s)/ receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

FEATURE HIGHLIGHTS

TRU-BEAM™ UV-C
Proprietary TRU-BEAM UV-C system. No replacements required.

Dual-sided Filtration
Combination filter featuring True HEPA to capture pollutants and Activated Carbon to capture odors and VOCs on both sides.

SensorPod™
Remote air quality monitor that ensures cleaner air, right where you need it.

Informs and Adapts
Color-coded illumination provides additional information by communicating air quality in real-time.

PRODUCT OVERVIEW

Air Purifier

TruSens Z-6000 Performance Air Purifiers-2

GETTING STARTED

Install the filter (combination True HEPA/Carbon)
Remove side panel door (a), prefilter (b) then bagged True HEPA/Carbon filter. Remove plastic bag from filter (c) and install inside the purifier with HEPA layer (white) on the inside, and the Carbon layer (black) on the outside. Replace the prefilter and side panel door.
NOTE: Perform steps on both left and right sides.

Set up
Plug-in your SensorPod™, and place upright on a tabletop or counter across the room, within line of sight of the purifier.
Plug-in your air purifier unit and power on. Place the purifier on a flat surface, free from obstructions.
Signal strength may vary by location. In the rare occasion that it doesn’t work – see page 16.

Start living with cleaner air!
The purifier will automatically adjust fan speeds based on the air quality readings from SensorPod, and will deliver purified air in the room.

CONTROL PANEL

SensorPod™ Signal Indicator
Power Button
Fan Speed Settings
Select fan speed or AUTO mode. In AUTO mode, purifier automatically adjusts fan speed based on air quality readings from SensorPod.
(AUTO mode only available when purifier is paired with SensorPod and receiving signal)

Dimmer Mode
Display illumination turns off without sacrificing the effectiveness of the purifier. Simply press the button again to bring back all display features.

Filter Indicator Reset
HEPA and Carbon indicators glow red when it is time to replace the filters. Simply hold Filter Reset button for 3 seconds to reset the indicators. If replacing the filter before HEPA and Carbon indicators turn red, hold Filter Reset button for 10 seconds to reset the indicators.
(See pages 14-16 for replacement instructions. Follow above Reset button instructions after replacing filter.)

UV Mode
UV-C within the purifier’s filter chamber are on when the symbol is on.

Timer Mode
Purifier will automatically turn off after 2, 4, 8, or 12 hours. To cancel this countdown, simply press button until no timer setting is displayed.

AIR QUALITY DISPLAY

Real-time Feedback
The enhanced SensorPod™ evaluates the condition of your air by measuring both particulate matter (PM1.0, PM2.5, PM10) and volatile organic compounds (VOCs). It calculates the overall air quality using a proprietary algorithm that is reactive to genuine increases in pollutants without overreacting.
The illuminated, color-coded display communicates good, moderate or poor air quality and a numeric value provides a greater level of detail.

In AUTO mode, the purifier automatically adjusts the fan speed in response to these air quality readings.

TruSens Z-6000 Performance Air Purifiers-11

SPECIFICATIONS

Air Inlet Dual-sided
Air Outlet Top
Smoke CADR Z-6000: 485
Room size at 2 air changes per hour (ACH) Z-6000: 1,750 ft² (162 m²)*

Z-7000: 2,000 ft² (186 m²)*
Room size at 4.84 air changes per hour (ACH)| Z-6000: 752 ft² (70 m²) | Z-7000: 805 ft² (75 m²)
Sensor| SensorPod™, works up to 49 ft (15 m) from purifier
Fan Speed Settings| Whisper, 1, 2, 3, Turbo, AUTO
Purification Levels| Washable Prefilter, Carbon, True HEPA, TRU-BEAM™ UV-C
Timer Settings| 2, 4, 8, 12 hr
Filter Change Indicators| HEPA, Carbon
Noise| Z-6000: 30.0 – 63.3 dB(A) | Z-7000: 30.0 – 65.9 dB(A)
Dimensions| Z-6000: 14.7 x 18.4 x 27.3 in (374 x 468 x 693 mm)

Z-7000: 14.7 x 18.4 x 31.7 in (374 x 468 x 806 mm)

Weight| Z-6000: 42.1 lb (19.1 kg) | Z-7000: 45.2 lb (20.5 kg)
Motor Type| DC motor
Power Requirements| 100-240VAC / 50-60 HZ
Power Consumption| Z-6000: 109.3 W | Z-7000: 118.7 W
Warranty| 2 years

Replacement Filters

Combination True HEPA/ Carbon Filter| Z-6000| AFCHZ6000-01| 2 pack|

Replace every 12 months

---|---|---|---|---
Z-7000| AFCHZ7000-01| 2 pack

CARE & MAINTENANCE

WARNING: Always power off the purifier by pressing the Power Button and unplugging the power cord.
To access the filter chamber, gently remove both side panel filter doors (Fig. A).

REPLACING TRUE HEPA/CARBON FILTERS

The HEPA and Carbon indicators will glow red when it is time to change the combination filter.

  1. Gently remove the washable prefilters from both sides (Fig. B).
    Refer to page 14 for cleaning instructions.

  2. Remove the current combination True HEPA/Carbon filters from both sides (Fig. C).

  3. Gently install the replacement combination True HEPA/Carbon filters with the HEPA layer (white) on the inside, and the Carbon layer (black) on the outside (page 8).

  4. Replace the prefilters and side panel filter doors on both sides (page 8).

  5. Plug-in and power on your purifier, and hold the Reset button until the red filter indicators turns off.

WASHING THE PREFILTERS
We recommend that you visually inspect the prefilters every month, and clean as needed. Hand wash the prefilters every time you change the combination True HEPA/Carbon filters.

  1. Gently remove both side panel filter doors.
  2. Gently remove the prefilters (Fig. D).
  3. Gently clean with a dampened cloth – allow prefilters to air dry before re-installing.
  4. Replace the prefilters (Fig. E) and both side panel filter doors.

FAQ & TROUBLESHOOTING

Where do I place the SensorPod™?

| Anywhere you want to measure the air quality within the room.

For optimal results, place the SensorPod™ up to 49 ft (15 m) away from the air purifier on a counter or table, within line of sight of the purifier. In Auto Mode, the purifier will work to distribute clean air until the SensorPod reads an acceptable level of air quality.

---|---

How often do I need to change the filters?

| That’s easy! The purifier’s replacement indicators will notify you when it is time to replace the combination True HEPA/Carbon filters.

Plan on replacing the filters every 12 months.

How often do I need to wash the prefilters?

| The prefilter captures larger particles and preserves the efficiency of the other filters, so we recommend that you visually inspect the prefilters every month and wash as needed.
Purifier won’t turn on.| Check that the power cord is connected securely to both the wall outlet and the purifier. Check if there is a power outage in the outlet by trying a nearby light or device, or by trying a working device in the same outlet.
Check that the filters and filter covers are fitted properly into filter chamber. Please contact us if you’re still having a problem! (page 17)
Purifier won’t go into Auto Mode. OR

Air quality indicators are off. OR

Purifier’s sensor signal indicator is blinking.

| First, check that the SensorPod is plugged-in and that its light is solid.

Next, check that the SensorPod is within range of the purifier (up to 49ft/15m).

If both are true and the connection is still failing, see below instructions on repairing the SensorPod’s connection.

---|---
I’ve lost my SensorPod™!| Don’t worry! Please contact our customer support team and you can order a replacement SensorPod. Follow the easy pairing instructions below to pair your replacement SensorPod with your existing air purifier!

Pairing SensorPod™ and Purifier
The SensorPod communicates with the purifier using radio frequency signals, and will be paired on the production line and ready for use when you open the box. In the rare event that the signal is interrupted, the purifier’s sensor indicator light will blink. You can repair the connection in just a few easy steps.

  1. Unplug the SensorPod.
  2. HOLD the Power Button on the purifier for 3 seconds, when you should hear two chimes.
  3. Plug-in the SensorPod and press and HOLD the pairing button underneath the SensorPod for 5-7 seconds (Fig. F).

WARRANTY

TruSens warrants the machine will perform to the specifications stated and be free from defects in materials and workmanship for a period of 2 years from date of purchase, subject to normal use. Dated proof of purchase will be required. Defects due to shipping, misuse, improper maintenance are not covered under this warranty. Only the use of TruSens brand accessories will guarantee the proper functioning and lifetime of your TruSens machine. Any damage to or malfunction of your air purifier resulting from the use of non- TruSens filters or UV bulbs may not be covered by this warranty or may result in a service fee if the damage or malfunction is determined to be caused by such use.
Within the warranty period, TruSens will at its own discretion either repair or replace the defective machine free of charge. Repairs or alternations made by persons not authorized by TruSens will void the warranty.

This warranty only applies to air purifiers operated in the United States and Canada. This warranty does not affect the legal rights which consumers have under applicable national legislation governing the sale of goods.

SUPPORT
We value your feedback. Please contact us to share your experience.
Visit our website at www.trusens.com
Email us at [email protected]
Call us at 1-833-TRUSENS (1-833-878-7367)

Subscribe to our YouTube channel TruSens & Follow us @TruSensWellness
www.trusens.com

©2022 ACCO Brands. All rights reserved. TruSens™, U™ & Design, SensorPod™ and Tru-Beam™ are trademarks of ACCO Brands.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TruSens User Manuals

Related Manuals