TruSens Z-1000 Small Air Purifier Owner’s Manual

June 6, 2024
TruSens

TruSens Z-1000 Small Air Purifier

SAFETY INFORMATION

PLEASE READ AND SAVE THESE INSTRUCTIONS

This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature. Unplug or disconnect the appliance from the power supply before replacing filters or UV bulb, or when appliance is not in use.

WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device. Do not operate any purifier with a damaged cord or plug, or if the wall socket is loose. Do not run cord under carpeting, throw rugs, runners, or similar coverings. Do not run cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.

WARNING: Skin or eye damage may result from directly viewing the light produced by the bulb in this apparatus. Always disconnect power before replacing or servicing. Replace bulb with UVLZ1000-01, Manufactured by ACCO Brands.

  • Remove all packaging, including the filter bag, before use.
  • Appliances that are obviously damaged must not be operated.
  • This appliance must only be connected to a wall socket outlet matching the supply plug type and rating stated on the rating plate.
  • Locate air purifier near the outlet wall socket and do not use extension cords.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Replace the UV bulb with the models specified within this manual.
  • Do not attempt to service or repair this product yourself.
  • Only use the purifier with the power cable provided.
  • Only clean this machine with a damp cloth, do not use solvents or bleach
  • Ensure appliance is always placed on firm level surface before operation.
  • Do not block or obstruct the air intake or outlet vents.
  • Do not insert fingers or other items into the air intake or outlet vents.

FEATURE HIGHLIGHTS

PureDirectTM Technology
Independent lab testing confirms that two airflow streams are better than one, moving air effectively and more comfortably throughout the room.

360° Purification
DuPontTM HEPA filter captures pollutants and VOC gases/odors from all directions. UV-C light destroys germs and bacteria that can get trapped in the filter.

Thoughtful Execution
Exceptional functionality wrapped in a contemporary design that fits any environment.

CONTROL PANEL

Power Button

Fan Speed Settings
Select fan speed: 1, 2, or Turbo.

UV Mode
UV bulb within the purifier’s filter chamber is on when the symbol is white. The symbol will glow red when it is time to replace the UV bulb.
(See page 13 for replacement instructions)

Filter and UV Indicator Reset
HEPA, Carbon and UV indicators glow red when it is time for each to be replaced. When 1 indicator is on, simply hold Reset button for 3 seconds to reset that indicator. When 2+ indicators are on, tap the Reset button to select the correct indicator (selected indicator will blink) before holding 3 seconds to reset that indicator. Power Button (See page 13 for replacement instructions)

(See pages 11-13 for replacement instructions. Follow above Reset button instructions after replacing filter.)

PRODUCT OVERVIEW


GETTING STARTED

  1. Remove plastic bag from filter
    Unscrew the bottom cover and remove the plastic bag from the filter.

  2. Re-attach filter
    Secure filter on the bottom cover and replace inside the purifier.

  3. Set up
    Plug-in your air purifier unit and power on. Place the purifier on a flat surface, free from obstructions:
    – where air can flow freely into the purifier from all sides
    – avoiding furnishings like bedding and curtains, as well as sources of heat or moisture

  4. Start living with cleaner air!
    Select your preferred fan speed and proprietary PureDirectTM technology will deliver purified air throughout the room!

SPECIFICATIONS

Air Inlet 360°
Air changed 2 times per hr 250 ft² (23 m²)
Air Delivery Type PureDirect ™
Fan Speed Settings 1, 2, Turbo
Purification Levels Carbon Prefilter, HEPA, UV
Filter Change Indicators Carbon, HEPA, UV
Noise 39 – 65 dB
Dimensions 7.7″ x 7.7″ x 17.9″ (195 x 195 x 451 mm)
Weight 7.7 lbs (3.5 kg)
Motor Type AC motor
Power Requirements 120v / 60 Hz
Power Consumption 40 W
Warranty 2 years

Replacement Filters & UV Bulb
2-in-1 HEPA drum filter| AFH-Z1000-01
Carbon filter (3-pack)| AFC-Z1000-01
UV Bulb| UVL-Z1000-01

CARE & MAINTENANCE

Accessing the filter chamber
  1. Always power off the purifier by pressing the Power Button and unplugging the power cord.
  2. Gently place the unit on its side on the floor so that the filter chamber cover and knob are exposed.
  3. Turn the knob counter-clockwise and remove the filter cover and 360° HEPA filter drum (Fig. A).
REPLACING

HEPA FILTER

  1. The HEPA indicator will glow red when it is time to change the entire HEPA drum filter.

  2. Gently pull the HEPA drum filter away from its place secured to the filter cover (Fig. B)

  3. Secure the replacement HEPA filter onto the filter cover (Fig. C).

  4. Gently replace the filter cover with filter drum into the filter chamber and onto the threading, and turn the knob clockwise until the knob and filter chamber cover are securely tightened (Fig. D).

  5. Plug-in and power on your purifier, and hold the Reset button until the red HEPA indicator turns off.

Note: HEPA drum filter (on page 10) will include 2 layers: Carbon Prefilter and HEPA

REPLACING

CARBON PREFILTER

  1. The Carbon indicator will glow red when it is time to replace the Carbon layer.

  2. Gently peel away the used Carbon layer from the fastener strips (Fig.E).

  3. Wrap a new Carbon layer around the filter drum and attach to the same fastener strips (Fig. F).

  4. Once the purifier is powered-on, hold the Reset button until the red Carbon indicator turns off.

Note: Carbon filter 3-pack (on page 10) will cover 3 Carbon changes between replacing the entire HEPA drum filter assemly (on page 11).

REPLACING UV BULB
  1. The indicator will glow red when it is time to replace the UV bulb.

  2. Remove HEPA filter drum (Fig. A), and use a screwdriver to remove the screw securing the UV housing (Fig. G).

  3. Gently remove the UV housing (Fig. H) and disconnect the UV bulb from the socket (Fig. I).

  4. Release carriage from the UV bulb (Fig. J).

  5. Secure carriage to new UV bulb (on page 10) (Fig. K) and connect UV bulb into purifier (Fig L).

  6. Replace the UV housing and use a screwdriver to tighten the fastening screw.

  7. Once the purifier is powered-on, hold the Reset button until the indicator turns white.

FAQ & TROUBLESHOOTING

How often do I need to change the filters?| That’s easy! The purifier’s replacement indicators will notify you when it is time to replace the Carbon or HEPA filters, or the UV bulb. Plan on replacing the Carbon every 3-4 months, HEPA every 12-15 months, and UV bulb every 1-3 years.
---|---
Purifier won’t turn on.| Check that the power cord is connected securely to both the wall outlet and the purifier. Check if there is a power outage in the outlet by trying a nearby light or device, or by trying a working device in the same outlet. Check that the HEPA filter is fitted properly into filter chamber.
Please contact us if you’re still having a problem! (page 15)

WARRANTY

TruSensTM warrants that the machine will be perform to the specifications stated and be free from defects in materials and workmanship for a period of 2 years from date of purchase, subject to normal use. Within the guarantee period, TruSens will at its own discretion either repair or replace the defective machine free of charge. Defects due to shipping, misuse, improper maintenance or the use of any parts from another manufacturer are not covered under this guarantee. Proof of date of purchase will be required. Repairs or alternations made by persons not authorized by TruSens will invalidate the guarantee. This guarantee does not affect the legal rights which consumers have under applicable national legislation governing the sale of goods.

SUPPORT

Thank you for welcoming TruSens into your home. Our customers are at the heart of what we do, and we strive to design products that fit your lifestyle. If you have any questions or feedback, please reach out!
Visit our website at www.trusens.com
Email us at [email protected]
Call us at 1-833-TRUSENS (1-833-878-7376)

Subscribe to our YouTube channel TruSens & Follow us @TruSensWellness

www.trusens.com

ACCO Brands 101 O’Neil Road Sidney, NY 13838 Tel: 607-563-9411

©2020 ACCO Brands. All rights reserved. TruSens™, U™ & Design and PureDirect™ are trademarks of ACCO Brands. DuPont™ & the Oval logo are trademarks or registered trademarks of E.I. du Pont de Nemours and Company used under license.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TruSens User Manuals

Related Manuals