SALUS KL04NSB Wiring Centre Extension for 4-Zone UFH Instruction Manual

June 6, 2024
SALUS

SALUS logo Wiring centre extension for 4-zone UFH
Model: KL04NSBSALUS KL04NSB Wiring Centre Extension for 4 Zone
UFH III 2021
Manual
SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
QR SALUS KL04NSB EN QG V001
Bar Code : 5060103692699

Introduction

The KL04NSB is an easy to connect four-zone extension for the KL08NSB wiring centre. It expands the system to up to12 zones in total

Product compliance

This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC 2014/30/EU, Low Voltage Directive LVD 2014/35/EU and RoHS directive 2011/65/EU.
The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com.

Safety information

Use in accordance with national and EU regulations. The device is intended for indoor use only in dry conditions. Product for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations.
Before attempting to set up and install, make sure that the device is not connected to any power source.
Installation must be carried out by a qualified person. Incorrect installation may cause damage to the devices. The KL04NSB should not be installed in areas where it may be exposed to water or damp conditions.

Technical Information

Power Supply 230 V AC
Total Load Max 3:00 AM
Outputs Terminals for actuators (230 V)
Dimensions [mm] 163 x 85 x 67

Wiring centre description

1. Serial connector
2. Power supply
3. Connection indicator
4. Power indicator| 5. NSB function terminals
6. Actuators connection
7. Thermostats connection
---|---

Serial connector

The Serial connector is used to connect the KL08NSN with the KL04NSB extension module to add functionality and support up to12 zones

SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
connector

Power Supply

SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
Power

The power supply for the wiring centre is 230 V ~ 50Hz.
Two-wire installation should be made in accordance with the applicable regulations

Connection indicator

After successful connection of KL08NSB with KL04NSB extension module red LED will light up constantly.

Power indicator

SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
icon5After connecting KL04NSB to the power supply, the Power red LED will light up.

NSB (Night Set Back reduction) function

NSB function is activated in non-programmable Salus thermostats of the Expert NSB, HTR, BTR series via external signal. NSB 230 V signal (night-time temperature reduction) is sent via an external timer or programmable thermostat connected to the wiring centre. Non-programmable thermostats are receiving NSB signals and reducing setpoint temperature (by switching to eco- mode). All thermostats have to be connected using a 4-wire cable (min. 4 x 0,75 mm2, max. 4 x 1,5 mm2 ).

  • OPTION 1
    SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
OPTION
    One Master thermostat which is common for thermostats from Group 1, Group 2 and Group 3 (one programmable thermostat e.g. VS30, other thermostats are programmable e.g. VS35).

  • OPTION 2
    SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
OPTION5
    Three Master thermostats.
    One for Group 1, one for Group 2 and one for Group 3 (three programmable thermostats e.g. VS30, other thermostats are nonprogrammable e.g., VS35).

  • OPTION 3
    SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
OPTION2
    One external clock is common for thermostats from Group 1, Group 2 and Group 3 (one external clock + daily regulators e.g. VS35).

  • OPTION 4
    SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
OPTION3 Three external clocks. One for Group 1, one for Group 2 and one for Group 3 (three external clocks + nonprogrammable regulators e.g. VS35).

Note: Terminals 1-4 and 5-8 are located in the KL08NSB wiring centre, while terminals 9-12 are located in the KL04NSB extension module.

Actuators connection

The actuator wires should be secured with the self-locking connectors in the appropriate zone. Up to 6 actuators with a load of up to 2 Watts each can be connected to a single one. Should more than 6 actuators be required in a zone using an additional relay to relieve the output?

SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
connector1

Thermostats connection

  • Connecting EXPERT NSB, HTR or BTR series thermostats
    SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
connection

  • Connecting a 230 V thermostat (e.g. SQ610 Quantum Thermostat)
    SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
connection2

  • Connecting ON/OFF battery-powered thermostat with voltage-free COM / NO output contacts (e.g. 091FL, RT310, RT510)

SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
connection3

Note: In NSB, HTR, ERT, BTR product series follow interchangeable signifying:
↑=SL
= NSB

INSTALLATION

SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
INSTALLATION1

Remove the top cover of the wiring centre extension and unscrew the main housing.

SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
INSTALLATION2

Mount the backside of the housing o the wall. When mounting on a DIN rail, open the hooks on the back of the housing.

SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
INSTALLATION3

Remove the appropriate piece of insulation from the wires.
Set includes supplementary accessories (to support the installation process).

SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
icon14SALUS KL04NSB Wiring
Centre Extension for 4 Zone UFH - INSTALLATION6

Thread the wires under the mounting bolt in the back part of the wiring centre extension.

SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
INSTALLATION10

Thread the wires through the slots in the top part of the wiring centre extension and connect them to the terminals.

SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
INSTALLATION15

Adjust the wires and screw the main housing of the wiring centre extension to the rear housing.

SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
INSTALLATION17

Connect the thermoelectric actuators wires.

SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
INSTALLATION18

Connect the serial cable to the KL08NSB and KL04NSB connector.

SALUS KL04NSB Wiring Centre Extension for 4 Zone UFH -
INSTALLATION19

Make sure that all the wires are properly connected, mount the top cover and power up the wiring centre and wiring centre extension- “Power” and “Connection” red LED diodes will light up indicating the correct connection with the KL08NSB wiring centre.

PRODUCER:
Salus Limited
6/F, Building 20E, Phase 3, Hong Kong Science
Park, 20 Science Park East Avenue, Shatin,
New Territories, Hong Kong

| IMPORTER:
QL CONTROLS Sp. z o.o. Sp. k.
ul. Rolna 4, 43-262 Kobielice
---|---

SALUS logowww.salus-controls.eu
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve
the right to change specification, design and materials of products listed in this
brochure without prior notice.SALUS KL04NSB Wiring Centre Extension for 4
Zone UFH - icon

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals